• Title/Summary/Keyword: 터널안전

Search Result 914, Processing Time 0.023 seconds

A Study on the Method of Quantitative Risk Analysis in Railway Tunnels (철도터널의 안전성 평가 기법에 관한 연구)

  • Park, Jung-Hyun;Cho, Kook-Hwan;SaGong, Myung;Kim, Hyo-Gyu
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1171-1176
    • /
    • 2011
  • According to the 'Rules on the Safety Standard of Railroad Facilities', the 'Detailed Safety Standards of Railroad Facilities' and 'the Standards for Railroad Design' unified of MLTM(Ministry of Land, Transport and Maritime Affairs), the risk analysis on the application of fire safety facilities should be quantitatively performed to ensure the safety in tunnels over 1km long. This paper aims at proposal of basic data for the safety facilities' planning with reasonable and appropriate scale through case studies on different model tunnels.

  • PDF

An Analysis of Stability on Rock Slope by Changing Water Level (지하수위 변화에 따른 암반사면의 안정성 해석)

  • Jang, Hyong-Doo;Yang, Hyung-Sik
    • Tunnel and Underground Space
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 2010
  • A quarry with 105 m height large cut slope was analyzed. Beside RMR and SMR methods, FLAC2D were adopted to analyze slope stability. As a result, slope of andesite had a possibility of failure. Wet slope showed low safety factor. Soil nailing was recommended to solve it. Since safety factor of slope largely depend on underground level, investigation for it seemed necessary.

In-situ Measurements of Time-dependent Rock Deformations at the Waste Isolation Pilot Plant in USA (미국 Waste Isolation Pilot Plant에서의 시간변동 거동 계측)

  • Sangki Kwon;Chul-Hyung Kang;Jongwon Choi
    • Tunnel and Underground Space
    • /
    • v.9 no.3
    • /
    • pp.175-184
    • /
    • 1999
  • Systematic measurements in the field are the key component in the design process to ensure that optimal and safe designs result. The instruments installed at the Waste Isolation Pilot Plant, a underground nuclear waste repository in U.S., for measuring rock deformation was reviewed. Also discussions about installation and measurement for better understanding the complex time-dependent deformational behavior of underground excavation were made.

  • PDF

Tunnel Safety Assessment by using the Concept of the Critical Strain in the Ground (한계변형률 개념을 활용한 터널안전성 평가)

  • Park, Si-Hyun;Park, Sung-Kun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.571-576
    • /
    • 2010
  • In this study, an application method of critical strains concept for tunnels' safety by using the values of measured displacements which are obtained in the field is discussed. The aim is to: (1) study on the engineering meanings of critical strains concept by reviewing the previous researches and application examples with measured displacement values; (2) study on the engineering reasonability of critical strains concept with the view point of a tunnel engineering and a geotechnical engineering; (3) study on the features of ground deformation due to tunneling and reciprocal relation between total displacement and measured displacement; (4) evaluate a tunnel safety by using domestic measurements collected in the field; and (5) re-evaluate the control criteria which were previously used in the field, with the view point of critical strains concept. Consequently, it was confirmed that critical strains in the ground has a reasonability and a possibility of unified or common concept with the view point of a tunnel engineering.

  • PDF

An Assessment of Safety Zone for Mountain Tunnel Portal Using Strength Reduction Technique (강도감소법을 이용한 산악터널 갱구부의 안전영역 평가)

  • Hong, Chang-Soo;Hwang, Dae-Jin;Lee, Kang-Ho;You, Kwang-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.925-930
    • /
    • 2006
  • During the excavation of a tunnel portal, failure zones around the tunnel heading occur and also the ground supports itself. In a portal, its location and the ground characteristic have a great influence on the stability of the tunnel. Therefore, the failure mechanism of a tunnel heading and how to assess the stability of the tunnel are very important. In this paper, the numerical analyses were executed to evaluate the safety factor using strength reduction technique. The influence area of an excavation was also predicted through a case study in which no-support case and support case with the Pattern P-6 were compared in terms of the ground class and the shear strain.

  • PDF

the case study of installation for the safety of railroad tunnel (철도터널 안전설비 설치 사례 연구)

  • Kim Sun-hong;Kim Dong-Ki;Nam Myong-sik;Jo Hyeong-je;Kim Jong-won
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.640-645
    • /
    • 2005
  • Safety requirment or guidance have been developing for a long time in the UIC, Germany, France, and Japan etc. Also, In Korea, the Ministry Construction & Transportation make an progress about this issue, document, called 'railroad tunnel safety standards 6th draft', was developed. In this paper, we'll show standard of other country and compare with Korea draft. next, we'll show some kind of railroad safety facility and installations and explain a relationship of safety issue and standards

  • PDF

Applicability of Safe Blast Vibration Limits to the Blasting Work near Safety Related Structures (안전관련 구조물 근접시공시 발파진동 허용기준의 적용성에 관하여)

  • 류창하;서우춘;정소걸;이종림;주광호;이대수
    • Tunnel and Underground Space
    • /
    • v.4 no.3
    • /
    • pp.287-296
    • /
    • 1994
  • Safety-related structures of power plants have to be protected against the effects of possible hazards and natural phenomena. Earthquakes are considered a major dynamic design loading as a requirement of plant design, but the effects of blast-induced vibratons are not. Due to the difficulties of obtaining construction site for new plants, following ones are inevitably being built in the site adjacent to existing power plants. Therefore considerable thought has been recently given to the dynamic loading generated by blasting works near the plants. In this paper, discussed is applicability of existing vibration standards and industrial codes to the blasting works near safety related structures. Also evaluated are the parameters for the safe vibration limits such as measure of vibration level, frequency consideration, structure response, propagation equation, etc.

  • PDF

A Study on Frequency and Time Domain Interpretation for Safety Evaluation of old Concrete Structure (노후된 콘크리트 구조물의 안전도 평가를 위한 초음파기법의 주파수 및 시간영역 해석에 관한 연구)

  • Suh Backsoo;Sohn Kwon-Ik
    • Tunnel and Underground Space
    • /
    • v.15 no.5 s.58
    • /
    • pp.352-358
    • /
    • 2005
  • For non-destructive testing of concrete structures, time and frequency domain method were applied to detect cavity in underground model and pier model. To interpret the measured data, time domain method made use of tomography which was completed with first arrivaltime and inversion method. In this steady, frequency domain method using Fourier transform was tried. Maximum frequency in the frequency domain was analyzed to calculate location of cavity.

On the Determination of Safe Charge Weigth from the Several Predictive Equations of Blast Vibration (발파진동 예측식을 이용한 안전장약량 산정문제에 관하여)

  • 김일중;김영석
    • Tunnel and Underground Space
    • /
    • v.5 no.2
    • /
    • pp.89-94
    • /
    • 1995
  • Regression analysis and a comparative study were carried out for 52 blast vibration data which were monitored by changing the monitoring distance and charge per delay. The results are as follows: 1) The square and cube root scalings and general equation which have a confidence level at the point of 90% and 99% are V90=33300(SD)-2.026 , V90=23600(SD)-1.993, V90=26300W0.755 R-2.007 and V99=48400(SD)-2.026, V99=34000(SD)-1.993 , V99=38100W0.755R-2.007, respectively. 2) There is need to decide the allowable max. charge weight per delay considering the cross points comparatively of the nomogram constructed using several predictived equations. 3) It is necessary to derive the predictive equation on the basis of blast vibration level monitored in field and to decide safe vibration level and the confidence level.

  • PDF

A Safety Analysis of Tunnel Lining for Monitoring (계측에 의한 터널 라이닝의 안전성 분석)

  • Woo, Jong-Tae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.103-110
    • /
    • 2002
  • Maintenance monitoring of the tunnel which offers continuous data during and after tunneling has been applying to tunnels in order to meet the maintenance of tunnel and to confirm continuous security of the tunnel after tunneling. But, the maintenance monitoring of tunnel results for long period is not easy to find, and moreover, the rational analysis method on tunnel monitoring has not been established yet. In this study, the relationships between displacement and stress of the tunnel concrete lining using various analysis methods are compared with maintenance monitoring. The tunnel behavior were measured in the subway tunnel passing comparative soft the weathering and analyzed both security and mechanical characteristics of the tunnel concrete lining. Also, analyzed relationship between residual water pressure applied on tunnel design and one obtained by monitoring.