• Title/Summary/Keyword: 태양 전지 모듈

Search Result 344, Processing Time 0.023 seconds

A Study on the Optimization of CP Based Low-temperature Tabbing Process for Fabrication of Thin c-Si Solar Cell Module (박형 태양전지모듈 제작을 위한 저온 CP 공정 최적화에 관한 연구)

  • Jin, Ga-Eon;Song, Hyung-Jun;Go, Seok-Whan;Ju, Young-Chul;Song, Hee-eun;Chang, Hyo-Sik;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.77-85
    • /
    • 2017
  • Thin crystalline silicon (C-Si) solar cell is expected to be a low price energy source by decreasing the consumption of Si. However, thin c-Si solar cell entails the bowing and crack issues in high temperature manufacturing process. Thus, the conventional tabbing process, based on high temperature soldering (> $250^{\circ}C$), has difficulties for applying to thin c-Si solar cell modules. In this paper, a conductive paste (CP) based interconnection process has been proposed to fabricate thin c-Si solar cell modules with high production yield, instead of existing soldering materials. To optimize the process condition for CP based interconnection, we compared the performance and stability of modules fabricated under various lamination temperature (120, 150, and $175^{\circ}C$). The power from CP based module is similar to that with conventional tabbing process, as modules are fabricated. However, the output of CP based module laminated at $120^{\circ}C$ decreases significantly (14.1% for Damp heat and 6.1% for thermal cycle) in harsh condition, while the output drops only in 3% in the samples process at $150^{\circ}C$, $175^{\circ}C$. The peel test indicates that the unstable performance of sample laminated at $120^{\circ}C$ is attributed to weak adhesion strength (1.7 N) between cell and ribbon compared to other cases (2.7 N). As a result, optimized lamination temperature for CP based module process is $150^{\circ}C$, considering stability and energy consumption during the fabrication.

Power variation of Solar cell according to Electrolyte (전해질에 따른 Solar Cell의 출력 변화)

  • Shin, Jun-Oh;Jung, Tae-Hee;Kim, Tae-Bum;Won, Chang-Sub;Ji, Yang-Geun;Kong, Ji-Hyun;Kang, Gi-Hwan;Ahan, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.471-472
    • /
    • 2009
  • 최근 태양전지의 내구성과 관련하여 모듈의 노화에 따른 효율 저하 현상이 대두되고 있다. 노화현상원인 중의 하나인 Hot spot 혹은 염분에 의한 백화현상으로 Solar Cell 과 EVA Sheet간 막들뜸 현상이 발생하며 그로 인한 공기 및 수분에 의해 금속 산화가 이뤄진다. 본 연구에서는 특히 전해질의 농도에 따른 금속의 산화와 그 출력에 대해 다룸으로써 태양광 발전 설치 지역 조건에 따른 Module의 내구성을 검토해 보았다. 산성비의 대부분을 구성하고 있는 황산과 질산의 PH를 0.1 간격으로 Split하여 농도의 변화에 의한 금속 부식과 그에 따른 전기적 저항 및 출력변화를 통해 태양광 Module 최적의 설치 지역조건을 제시하였다.

  • PDF

Characteristics of Solar Cell by Thermal Shock test (열충격 시험을 통한 태양전지 특성)

  • Kang, Min-Soo;Jeon, Yu-Jae;Son, Seon-Ik;Kim, Do-Seok;Shin, Young-Eui
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.91-95
    • /
    • 2012
  • 본 연구에서는 열충격 시험을 통하여 Cell레벨에서의 효율저하 특성을 분석하였다. 열충격 시험은 PV모듈의 시험 규격인 KS C IEC-61215를 이용하여 보다 가혹한 조건인 $-40^{\circ}C$에서 $120^{\circ}C$의 조건으로 500사이클 수행하였다. I-V 측정을 통하여 효율을 분석한 결과, 열충격 시험 전 13.9%에서 열충격 시험 후 11.0%로 효율이 저하 됐으며, 감소율은 20.9% 나타났다.EL촬영을 통해 표면을 분석한 결과 Ribbon접합부 및 Gridfinger의 손상으로 확인 됐으며, 보다 정확한 효율 저하의 원인을 분석하기 위해 단면분석을 실시한 결과 표면손상으로 확인 되었던 위치의 Cell내부에서도 Crack을 확인 할 수 있었다. 또한 FF값을 분석한 결과 열충격 시험 전 72.3%에서 시험 후 62.0%로 11.8%의 감소율을 보였다. 따라서, 경년 시 나타나는 효율저하는 Cell자체의 소모전력 증가와 외부환경에 의한 표면 손상 및 Cell내부의 Crack에 기인하여 가속된다고 판단된다.

  • PDF

A Study on EVA Optical Characteristics By Generation Temperature of PV module (Photovoltaic module의 발전 온도에 따른 EVA 광 특성 연구)

  • Woo, Sung-Cheol;Jung, Tae-Hee;Min, Youn-Ki;Kang, Ki-Hwan;Ahn, Hyeung-Ken;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.31-35
    • /
    • 2011
  • Photovoltaic modules are well known to be one of the most eco generation of electricity. But usually study solar cell. Otherwise, PV modules are also important in power generation. We have to check other subsidiary materials. In this work benefit of using optically superior encapsulation materials(EVA) in generation temperature is demonstrated. Optical characterization of three EVA products demonstrates reduced transmission in the visible ray region of the solar spectrum. It will have a decisive effect to the module efficiency. Test is shown reduction of reflectance and transmittance. Reflections is dependent on the low iron glass. It can be seen between a specific wave length(240~350mm) about 1%. Transmittance in the entire ray region of light is markedly reduced to depending on the temperature rise. The graph is shown optical properties on EVA. Transmission was reduced. about 1%.

  • PDF

Study on the tree-mimic array of solar cell modules (수목형상에 따른 태양전지 모듈의 배열 연구)

  • Kim, Ki-Hyun;Yun, Rin
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.32-39
    • /
    • 2011
  • This study is about the installation of the solar cell modules. The solar cell modules are built by the tree-mimic structure, and the performance is compared with that of the flat-plate type solar cell module installation. The mathematical tree model, which was suggested by Fisher and Honda, is utilized to determine the location of the solar cell modules for the tree-mimic type. The experiment shows that the generated electric power of the flat-plate type is higher than that of the tree-mimic type by 30% for one month of July. This lower performance for the tree-mimic type comes from the shading effects among the solar cell modules. The theoretical calculation for the absorbed solar radiation on the two types of solar cell installation shows that the tree-mimic type is higher than the flat-plate type by 8.5%. The shading area for the tree-mimic model is calculated with time by using the 3D-CAD, which will be utilized for the optimization of the tree-mimic model in the future.

A Study on the Evaluation of Power Performance according to Temperature Characteristics of Amorphous Transparent Thin-Film (비정질 박막 투과형 태양전지모듈의 온도특성에 따른 발전성능 평가 연구)

  • An, Young-Sub;Song, Jong-hwa;Lee, Sung-jin;Yoon, Jong-ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.45-48
    • /
    • 2009
  • This study evaluated the influence of temperature on the PV module surface on power output characteristics, especially for an amorphous transparent thin-film PV module which was applied to a full-scale mock-up model as building integrated photovoltaic system. The tested mock-up consisted of various slopes of PV module, facing to the south. The annual average temperature of the module installed with the slope of $30^{\circ}$ revealed $43.1^{\circ}C$, resulting in $7^{\circ}C$ higher than that measured in PV modules with the slope of $0^{\circ}$and $90^{\circ}$ did. This $30^{\circ}$ inclined PV module also showed the highest power output of 28.5W (measured at 2 PM) than other two modules having the power output of 20.4W and 14.9W in the same time for $0^{\circ}$ and $90^{\circ}$ in the slope, respectively. In case of the $30^{\circ}$ inclined PV module, it exhibited very uniform distribution of power output generation even under the higher temperature on the module surface. Consequently, the surface temperature of the PV module analyzed in this study resulted in 0.22% reduction in power output in every $1^{\circ}C$ increase of the module surface temperature.

  • PDF

Prediction of temperature distribution in PV module using finite element method (유한 요소 해석 프로그램을 이용한 모듈 내 온도 분포 예측)

  • Park, Young-Eun;Jung, Tae-Hee;Go, Seok-Hwan;Ju, Young-Chul;Kim, Jun-Tae;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.65-72
    • /
    • 2016
  • PV module is installed in various outdoor conditions such as solar irradiation, ambient temperature, wind speed and etc. Increase in solar cell temperature within PV module aggravates the behaviour and durability of PV module. It is difficult to measure temperature among respective PV module components during PV module operating, because the temperature within PV module depends on thermal characteristics of PV module components materials as well as operating conditions such as irradiation, outdoor temperature, wind etc. In this paper, simulation by using finite element method is conducted to predict the temperature of each components within PV module installed to outdoor circumstance. PV module structure based on conventional crystalline Si module is designed and the measured values of thickness and thermal parameters of component materials are used. The validation of simulation model is confirmed by comparing the calculated results with the measured temperatures data of PV module. The simulation model is also applied to estimate the thermal radiation of PV module by front glass and back sheet.

Analysis of Output Characteristics of Lead-free Ribbon based PV Module Using Conductive Paste (전도성 페이스트를 이용한 무연 리본계 PV 모듈의 출력 특성 분석)

  • Yoon, Hee-Sang;Song, Hyung-Jun;Go, Seok-Whan;Ju, Young-Chul;Chang, Hyo Sik;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.1
    • /
    • pp.45-55
    • /
    • 2018
  • Environmentally benign lead-free solder coated ribbon (e. g. SnCu, SnZn, SnBi${\cdots}$) has been intensively studied to interconnect cells without lead mixed ribbon (e. g. SnPb) in the crystalline silicon(c-Si) photovoltaic modules. However, high melting point (> $200^{\circ}C$) of non-lead based solder provokes increased thermo-mechanical stress during its soldering process, which causes early degradation of PV module with it. Hence, we proposed low-temperature conductive paste (CP) based tabbing method for lead-free ribbon. Modules, interconnected by the lead-free solder (SnCu) employing CP approach, exhibits similar output without increased resistivity losses at initial condition, in comparison with traditional high temperature soldering method. Moreover, 400 cycles (2,000 hour) of thermal cycle test reveals that the module integrated by CP approach withstands thermo-mechanical stress. Furthermore, this approach guarantees strong mechanical adhesion (peel strength of ~ 2 N) between cell and lead-free ribbons. Therefore, the CP based tabbing process for lead free ribbons enables to interconnect cells in c-Si PV module, without deteriorating its performance.

An Energy Harvesting and Profiling System for Smart Video Devices (스마트 비디오 디바이스를 위한 에너지 하비스팅 및 프로파일링 시스템)

  • Kang, Doo-sik;Kim, Jun-sik;Park, Keon-woo;Lee, Myeong-jin
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.99-106
    • /
    • 2017
  • In this paper, an energy harvesting and profiling system is designed for smart video devices in internet of things environments without dedicated power source. The energy harvesting module provides the harvested energy from solar panel to the smart video device. The energy profiling module measures the battery outflow current and the battery voltage of the smart video device and the consumed energy of processes, and calculate the harvested energy from the energy harvesting module to the smart video device and the total energy consumption of the smart video device. The accuracy of the harvested energy measured by the device energy profiling module is validated by comparing with the calculated energy using the regional solar radiation provided by Korea Meteorological Administration. Energy harvesting data from the designed energy harvesting and profiling system can be used to design the perpetual operation of smart video devices or Internet of Things sensors.

A Study on Development of Power Analysing Device for PV Module (태양전지 모듈의 발전량 분석 장치 개발에 관한 연구)

  • Moon, Chae-Joo;Kwak, Seung-Hun;Jang, Yeong-Hak;Kim, Tae-Gon;Kim, Eui-Sun;Kim, Tae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1~10 of M), (11~20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is-2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by $1^{\circ}C$, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by-0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced.