• 제목/요약/키워드: 태양일사량

Search Result 398, Processing Time 0.031 seconds

A comparative study on implementation methods of PWM controller in small scale solar energy system (소용량 태양광발전용 PWM제어기의 하드웨어 구현방식 비교)

  • Lee, Hoong-Joo;Lee, Jun-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.5
    • /
    • pp.963-969
    • /
    • 2006
  • In this study, we designed a digital fuzzy logic controller based on FPGA and microprocessor for MPPT of the solar power generation system. A fuzzy algorithm to control the power tracking function of a boost converter has been built into the FPGA, and applied to the small scaled solar power generation system. The embodied controller showed a stable operation characteristic with the small output voltage ripple for the intensity change of solar radiation. This result proves that the implementation of the power tracking controller using FPGA is an effective way compared to the existing one using microprocessors.

  • PDF

A Survey of Direct Normal Insolation Resources for the Construction of Solar Thermal Power Generation Sites in Korea (국내 태양열발전단지 건설을 위한 법선면 직달일사량 자원조사)

  • Jo, Dok-Ki;Kang, Young-Heack;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2005
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1990 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research's new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean $5.4kWh/m^2/day$ of the direct normal insolation was evaluated for clear day all over 16 areas in Korea. 2) Clear day's direct normal insolation of spring and summer were $5.53kWh/m^2/day$ and $5.84kWh/m^2/day$, and for fall and winter their values were $5.3kWh/m^2/day$ and $4.94kWh/m^2/day$ respectively. So, spring and summer were higher, and fall and winter were lower than the yearly mean value.

Prediction and Analysis of Photovoltaic Modules's Output using MATLAB (MATLAB을 이용한 태양광 모듈의 출력 예측 및 해석)

  • Heo, Yun-Seok;Kim, Jae-Gyu;Kim, Ji-Man;Kwon, Bo-Min;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2963-2967
    • /
    • 2010
  • In this paper, we have predicted and analyzed the MSX 60 photovoltaic module's output according to the temperature and solar radiation conditions by MATLAB program. 2 and 3-dimensional I-V curves of the PV module considered temperature, series resistance and solar radiation variation. are shown. Also, calculated PV's electrical parameters are Isc = 3.8 A, Voc = 21 V, Pmax = 60 W. Compared with the actual photovoltaic module's data, these simulated results agreed well with within the manufacturer's maximum error range 3%.

A Survey of Direct Normal Insolation Resources for the Construction of Solar Concentrating Power Generation Sites in Korea (국내 고집광 태양에너지 발전단지 건설을 위한 법선면 직달일사량 자원조사)

  • Jo, Dok-Ki;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.209-214
    • /
    • 2008
  • Since the direct normal insolation is a main factor for designing any solar thermal power system, it is necessary to evaluate its characteristics all over the country. We have begun collecting direct normal insolation data since December 1992 at 16 different locations and considerable effort has been made for constructing a standard value from measured data at each station. KIER(Korea Institute of Energy Research)'s new data will be extensively used by solar thermal concentrating system users or designers as well as by research institutes. From the results, we can conclude that 1) Yearly mean 2.67 kWh/$m^2$/day of the direct normal insolation was evaluated for all days all over the 16 areas in Korea. 2) All day's direct normal insolation of spring and summer were 2.91 kWh/$m^2$/day and 2.23 kWh/$m^2$/day, and for fall and winter their values were 2.78 kWh/$m^2$/day and 2.77 kWh/$m^2$/day respectively. So, spring, fall and winter were higher, and summer was lower than the yearly mean value

  • PDF

A Study on the Estimating Direct Normal Insolation Using Horizontal Global Insolation for Solar Thermal Generation System Installation in Korea (법선면 직달일사량 예측기법을 이용한 한반도에서의 태양열발전단지 건설을 위한 최적지 선정에 관한 연구)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.77-87
    • /
    • 2012
  • Images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth's surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. For the validation, estimated direct normal Insolation is compared with observed direct normal Insolation at 16 sites over the Korean peninsular from January 1982 to December 2010. Estimated direct normal Insolation shows reliable results with average deviation of -5.4 to +5.9% from the measured values and the yearly averaged direct normal Insolation of Korean peninsula was turned out to be 2.93 $kW/m^2/day$.

Estimation of Solar Radiation Distribution in Korea Using a Satellite (인공위성을 이용한 국내 일사량 분포 예측)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.99-106
    • /
    • 2011
  • Since the solar energy resource is the main input for sizing any solar photovoltaic system, it is essential to utilize the solar radiation data as an application and development of solar energy system increase. It will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth"s surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2009. The Result of analysis shows that the annual-average daily global radiation on the horizontal surface is 3.56 kWh/ $m^2$/day and estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.27 to +3.65% from the measured values.

An Analysis of Global Solar Radiation using the GWNU Solar Radiation Model and Automated Total Cloud Cover Instrument in Gangneung Region (강릉 지역에서 자동 전운량 장비와 GWNU 태양 복사 모델을 이용한 지표면 일사량 분석)

  • Park, Hye-In;Zo, Il-Sung;Kim, Bu-Yo;Jee, Joon-Bum;Lee, Kyu-Tae
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.129-140
    • /
    • 2017
  • Global solar radiation was calculated in this research using ground-base measurement data, meteorological satellite data, and GWNU (Gangneung-Wonju National University) solar radiation model. We also analyzed the accuracy of the GWNU model by comparing the observed solar radiation according to the total cloud cover. Our research was based on the global solar radiation of the GWNU radiation site in 2012, observation data such as temperature and pressure, humidity, aerosol, total ozone amount data from the Ozone Monitoring Instrument (OMI) sensor, and Skyview data used for evaluation of cloud mask and total cloud cover. On a clear day when the total cloud cover was 0 tenth, the calculated global solar radiations using the GWNU model had a high correlation coefficient of 0.98 compared with the observed solar radiation, but root mean square error (RMSE) was relatively high, i.e., $36.62Wm^{-2}$. The Skyview equipment was unable to determine the meteorological condition such as thin clouds, mist, and haze. On a cloudy day, regression equations were used for the radiation model to correct the effect of clouds. The correlation coefficient was 0.92, but the RMSE was high, i.e., $99.50Wm^{-2}$. For more accurate analysis, additional analysis of various elements including shielding of the direct radiation component and cloud optical thickness is required. The results of this study can be useful in the area where the global solar radiation is not observed by calculating the global solar radiation per minute or time.

Direct and Diffuse Radiation Data in Naju During May 2019 to November 2020 (농업적 활용을 위한 산란일사와 직달일사 관측 자료: 나주에서 2019년 5월부터 2020년 11월까지)

  • Kim, Hyunki;Moon, Hyun-Dong;Cho, Yuna;Sin, Seo-Ho;Kim, Jong-Hyeon;Lee, Yang-Won;Cho, Jaeil
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.2
    • /
    • pp.134-140
    • /
    • 2021
  • Global solar radiation consists of direct and diffuse radiations. Both components are necessary for not only atmospheric science and solar energy domains but also agricultural applications. In this study, the data of direct and diffuse radiations are uploaded to Github. It was observed in Naju during May 2019 to November 2020. Using this data, the previous empirical equations using the relation between clearness index and diffuse ratio were validated. All coefficients of determination (R2) and RMSE were similar as 0.79~0.80 and 0.13~0.15. However, to get the lower RMSE, other non-linear approaches will be required with more observation data.

The Operating Characteristics Analysis of Utility Interactive PV Power Generation System (계통연계형 태양광 발전시스템의 운전특성 분석)

  • 이현우;고강훈
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.23-30
    • /
    • 2003
  • This paper analyzes the characteristic of utility connection type solar power generation system which it is available to connect the utility. And the operation characteristic of this system is compared and analyzed when it is operated in the real system. The constructional and operational problem were obtained by that result. Overcoming that defect is that finding the proper place to be well operated and to find the best place for getting the sunshine data. This method could increase the efficiency of the generation system. And more, current OS in operating system and monitoring management couldn't solve the problem so that improving OS and constructing data backup system should be implemented, This paper proposes the plan to solve that defect in the real system.

A Study on the Utility Interactive Photovoltaic System using a Chopper and a PWM Inverter (쵸퍼와 PWM 전압형 인버터를 이용한 계통연계형 태양광발전시스템에 관한 연구)

  • 유택빈;성낙규;이승환;김성남;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.131-137
    • /
    • 1998
  • The solar cells should be operated at the maximum power point because its output characteristics are greatly fluctuated on the variation of insolation, temperature and load. Photovoltaic system needs an inverter which can interface the dc output power of solar cell with the residential ac load. The inverter has to supply a sinusoidal current and voltage to the load and the utility line with a high power factor. This paper proposes an utility interactive photovoltaic system designed with a step-up chopper and a PWM voltage source inverter. The step-up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power points of solar cell without any influence on the variation of insolation and temperature. The voltage source inverter operates in a manner that its output voltage is in phase with the utility voltage. The inverter supplies an ac power with high factor and low level of harmonics to the load and the utility power system.