• Title/Summary/Keyword: 태양열집열판

Search Result 38, Processing Time 0.023 seconds

직사각형 전도성 장애물을 갖는 밀폐공간내에서의 자연대류

  • 추홍록
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.229-234
    • /
    • 1997
  • 밀폐공간내에서 일어나는 자연대류 열전달은 태양열 집열판, 연료탱크, 원자로의 핵반응로, 초전도 자성체의 냉각 및 건물이나 방의 효율적인 열설계, 화재시의 안전대책등 공업적으로 그 응용성이 매우 광범위하고 다양하게 생활주변에서 흔히 볼 수 있다. 밀폐공간내에 경계층 유동이 존재할 경우, 이 경계층 흐름은 일반적으로 외부유동에서의 경계층 유동과는 달리 코어영역(Core region)에서의 흐름과 서로 밀접한 관계가 있다. (중략)

  • PDF

Evaluation of Process Parameter to Laser Welding of Solar Panel (태양열 집열판의 레이저용접을 위한 공정변수 평가)

  • Kim, Yong;Park, Ki-Young;Kim, Bu-Hwan
    • Laser Solutions
    • /
    • v.14 no.4
    • /
    • pp.9-13
    • /
    • 2011
  • The solar panel that consists of copper plate and copper tube was successfully welded by ultrasonic seam welding. However it was not only expensive the copper material but also ultrasonic welding has many problem such as high error rate, difficulty of dissimilar material welding, noise, etc. At this study, the laser welding of solar panel with aluminum plate instead of copper. The welding were carried out with the pulsed Nd:YAG laser and the weld bead geometry was measured with the variation of pulse energy. Consequently, there was no difference between the ultrasonic and the laser welding on the performance of heat transfer capacities. Also the formation of intermetalic compound such as CuAl2 was increased with the pulse energy.

  • PDF

Studies on the Focusing Solar Agricultural Crop Dryer - Part1. Heat Efficiency of Aluminum-laminated Aeryl Film Solar Heater - (농산물(農産物) 건조용(乾燥用) 곡면집광식(曲面集光式) 태양열(太陽熱) 이용(利用) 장치(裝置)에 관한 연구(硏究) - 제1보(第1報). 알루미늄-아크릴 필림을 이용(利用)한 태양열(太陽熱) 집열장치(集熱裝置)의 열이용(熱利用) 효율(?率) -)

  • Chun, Jae-Kun;Mok, Chul-Kyoon;Kim, Hyun-Uk
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.8-12
    • /
    • 1979
  • A cylindrical solar energy focusing collector constructed using aluminum-laminated film plastered on the acrylic plate and examined its performances under the Korean local weather conditions. The reflector surface of this collector· evidenced the reflectivity of 66.1%,which was satisfactory value that could be applicable to the solar collector for its low price and at·availability. Collector efficiency measured at the heat exchanger fluid in absorber-copper pipe black colored was 73% and the resulting natural convection of the heat transfer media (water) was recorded up to 2.82 cm/sec. The overall efficiency of the solar heater in operation was 28.6% and it was correlated with the solar energy input and the temperature elevation difference gained.

  • PDF

Thermal and Fluid Flow of the Air Layer in a Flat Type Solar Collector (평판형 태양열 집열판 공기층의 열 및 유체유동)

  • Bae, K.Y.;Yi, C.S.;Lee, K.S.;Chung, H.S.;Jeong, H.M.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2001
  • This study represents numerical analysis on the thermal and fluid flow of the air layer in a solar collector. The boundary conditions was assumed that the top and bottom wall of the air layer have a heating and cooling surface, respectively, and this calculation model have a solid body with a cooling temperature of $20^{\circ}C$. As the results of simulations, the magnitudes of the velocity vectors and isotherms are increased proportionally to the tilt angles. As the tilt angle is increased, the mean Nusselt numbers are increased and the maximum value of the mean Nusselt number was appeared at tilt angle $\theta=75^{\circ}$.

  • PDF

The Characteristics of Temperature Distributions for Flat Tube Type Solar Collector Type (평판형 태양열 집열판의 집열관 온도분포 특성)

  • Mo, J.G.;Bae, C.H.;Jeong, H.M.;Chung, H.S.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.85-91
    • /
    • 1999
  • This study represented experimental research on the flat-plate solar collector. The heat performances were measured the tube array surface temperature by thermal-couple. The solar collector($W{\times}H$) of $580{\times}1100$, various tilt angles of 30, 45, 60 degree and the internal tube number of 4, 6, 8, 10(ea) were utilized in the present investigation. It is found that the thermal concentration is higher as the tilt angle become larger and the solar tubes are more and more. In this stuby obtained results of following: The array of tubes in collector has the best nice in that the number of tube is eight and the tilt angle is 60 degree. The collect energy by each tube array shown high value by increase the number of tubes and tilt angles. In addition to, the collect energy depends on by the tilt angle than the number of tube.

  • PDF

Window Integrated Solar Collectors (창호일체형 태양열 집열기)

  • Park, Seong-Bae;Lim, Seong-Whan;Park, Mann-Kwi
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

Comparison Between Two Solar Absorption Cooling System Using Single Effect and Single Effect/Double Lift Cycle (일중효용 사이클과 일중효용/2단승온 사이클을 이용한 태양열 흡수식 냉방시스템의 비교)

  • 정시영;이상수;조광운;백남춘
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.267-276
    • /
    • 2000
  • A numerical study has been carried out to find out the optimal design condition of a solar absorption cooling system. The system was composed of solar collectors and an absorption chiller with LiBr/water The System performance with commercial single effect(SE) cycle and a new single effect/double lift(SE/DL) cycle utilizing low temperature hot water was calculated and compared. It was found that the required solar collector area grew exponentially as the overall heat loss coefficient of solar collectors increased. For instance, the required area for cooling capacity of 1 USRT was $17m^2$ if heat loss coefficient was 4 W/$m^2\;cdot\;K$. If heat loss coefficient was doubled($8\;W/m^2\;cdot\;$K), the required collector area was increased by 6 times($100m^2$) .It was also found that the SE-cycle as the heat loss coefficient of solar collectors increased. Generally, a SE/DL-cycle seems to be more advantageous than a SE-cycle if loss coefficient of solar collector is greater than 4 W/$m^2\;cdot\;K$.

  • PDF

Effect of Vacuum in a Non-glass Vacuum Tube on the thermal behavior of the Absorber Plate (비유리식(nonglass) 진공관의 진공도가 집열판의 열적 특성에 미치는 영향)

  • Oh, Seung-Jin;Hyun, Jun-Ho;Kim, Nam-Jin;Lee, Yoon-Joon;Chun, Won-Gee
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.67-73
    • /
    • 2008
  • This study has been carried out to investigate the effect of vacuum on the thermal performance of a nonglass evacuated tube. A series of measurements are made indoors to monitor the temperature change of the absorber plate contained in the evacuated tube under different conditions of vacuum and heat fluxes. Those temperatures measured at the thermal equilibrium could be used to assess the heat losses to the ambient in link with the steady operation of non-glass evacuated tubes for solar exploitation.

Response Surface Approach to Design Optimization of Regenerator Using Hot Air Heated by Solar Collector (태양열 온풍 이용을 위한 재생기의 설계 최적화 모델에 관한 연구)

  • Woo, Jong-Soo;Choi, Kwang-Hwan;Yoon, Jeong-In
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.7-14
    • /
    • 2003
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an energy efficient regenerator, this study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called response surface methodology(RSM), which may provide a functional relationship between independent and dependent variables. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

Numerical Analysis of Natural Convection in Inclined Flat Plate Enclosures (경사진 평판형 밀폐 공간에서의 자연 대류 현상의 수치 해석)

  • Kim, Yong Hyun;Koh, Hak Kyun;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.24-38
    • /
    • 1985
  • 경사진 밀폐 공간에서 마주 보는 두 벽면의 온도 차로 인하여 발생되는 자연 대류 현상은 여러 공학 분야에서 볼 수 있는 중요한 열전달 현상으로서, 최근 들어 평판형 태양열 집열기를 설계하려는 사람들에게 많은 관심의 대상이 되고 있다. 평판형 태양열 집열기의 경우 덮개판으로 부터의 대류 열손실을 감소시킴으로서 집열 효율을 높일 수 있을 뿐만 아니라 사용목적에 따라 소형 집열기를 제작할 수 있어 경제적으로 유리하게 될 것이다. 밀폐된 공간에서 최초에 정지 상태에 있는 얇은 유체층을 하부에서 가열시켜 주면 열팽창 현상이 일어나고, 이것에 의한 부력이 점도나 열전도도 등의 안정화 요인을 극복할 수 있을 정도로 커지면 System이 불안정하게 되어 자연 대류 현상이 수반되며 이 때문에 열전달율이 급격히 증가하게 된다. 이러한 현상의 지배 방정식은 연립 비선형 편미분 방정식으로 특수한 경계 조건외에는 일반적으로 해석적 해를 구하기가 어렵기 때문에 실험적 연구가 많이 실시되어 왔고 이들 결과의 대부분은 전반적인 열전달 특성치만을 구하는데 집중되어 왔다. 본 연구에서는 수치 해석법의 하나인 유한 차분법을 도입하여 이차원으로 가정한 경사진 평판형 밀폐 공간에서의 자연 대류 현상의 지배 방정식을 유한 차분화시켜, $$2.74{\times}10^3\leq_-Gr\leq_-2.0{\times}10^6$$, Pr=0.73, $$15^{\circ}\leq_-a\leq_-150^{\circ}$$, 종횡비는 1, 2, 3, 5, 9에 대하여 정상 상태에서의 해를 구하면서 수치적으로 실험하였다. 본 연구에서 얻어진 결론을 요약하면 다음과 같다. (1) 해석적으로 구하기 어려운 경사진 밀폐 공간에서 자연대류현상의 지배 방정식을 유한 차분법으로 해결할 수 있으며, 대류항과 확산항을 따로 고려한 유한차분법이 효과적임을 확인하였다. (2) 저온과 고온 벽면에서의 온도를 각각 균일하게 놓고 단변으로 이루어진 벽면은 완전히 절연되어 있는 경우에 대하여 수치해를 구한결과, 이전의 해석적 및 실험적 결과와 일치하였으며, 시간의 경과에 따른 온도 및 유선의 변화를 현상학적으로 관찰할 수 있었다. (3) 평균 열전달 계수에 미치는 경사각의 효과를 살펴본 결과 종횡비가 1 인 경우 경사각이 $45^{\circ}$에서, 종횡비가 2, 3, 5, 9인 경우 경사각이 $60^{\circ}$에서 각각 평균 열전달 계수 최대치가 나타났다. (4) Ra수(Rayleigh number) 가 증가될수록, 경사각에 상관없이 평균 열전달 계수도 증가되었다. 한편 Ra수 및 경사각의 변화에 따라 종횡비가 증가될수록 평균 열전달 계수는 경사각이 $90^{\circ}$인 경우를 제외하고는 감소됨을 볼 수 있었다. 경사각이 $90^{\circ}$인 경우, 평균 열전달 계수는 종횡비가 2 인 곳에서 최대치를 얻을 수 있었으며, 종횡비가 계속 증가될수록 평균 열전달 계수는 점차 감소되어짐을 볼 수 있었다.

  • PDF