지하공간의 자연환기를 위한 태양 굴뚝 시스템의 응용 (Application of Solar Chimney System for Natural Ventilation in Underground Space)

  • 장향인;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제30권2호
    • /
    • pp.87-95
    • /
    • 2010
  • This study analyzed the performance of solar chimney system for natural ventilation in underground space. A mathematical model of the solar chimney was proposed in order to predict its performance under varying parameters and Korea climatic condition. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the ventilation performance of the solar chimney was determined by the temperature difference of air channel and inlet, and the temperature difference was influenced by insolation, stack height and distance of air gab. Also the solar chimney system can provide $262.9m^3/h$ of annual average ventilation rate. Because seasonal differences of ventilation rate was calculated within 25%, the solar chimney system can be used for every season in Korea climatic condition. Through this study, performance of solar chimney system for natural ventilation was verified by numerical method. Consequently, the solar chimney system is proved to be effective device for natural ventilation utilizing at all times, and the additional studies should be made through the experimental method for imagineering and commercialization.

겨울철 건물 열환경 개선을 위한 태양굴뚝 시스템의 응용 (Application of the Solar Chimney System for Improving the Thermal Environment in Winter)

  • 오주홍;김의종;이현수;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제35권5호
    • /
    • pp.39-48
    • /
    • 2015
  • In this study, the solar chimney, one of the passive solar systems, is proposed as a method to improve the thermal environment of northern zones in buildings. As this well-known system has rarely been used in building projects, an adequate application of the system is proposed in this paper: the solar chimney system is designed to meet the required ventilation rate and consequently to reduce the ventilation load in the northern part of a building. To investigate such a possibility, a numerical model for the system is developed, and results of numerical tests are used for energy simulations. The results were taken into account for test simulations in EnergyPlus. As a result, approximately 75% of the volumetric ventilation rate required in the north zone could be supplied with the air volume acquired through the system and the monthly mean load was reduced by 29.5%, from 1.584 kWh to 1.117 kWh. The analyses of hourly mean heating and ventilation load over the heating period indicated that the system was very effective at around 13:00. Results show that 33% reduction in the ventilation load and 17% in the heating load for the north zone could be acquired through this system.

단열재의 두께 및 연돌높이에 따른 태양열 굴뚝의 자연환기 성능에 관한 실험적 연구 (The Experimental Study on the Natural Ventilation Performance of Solar Chimney by the variation of Insulation Thickness and Height)

  • 조성우;김동완;임영빈
    • 한국태양에너지학회 논문집
    • /
    • 제22권3호
    • /
    • pp.39-46
    • /
    • 2002
  • The results of experiment on the performance of natural ventilation by insulation thickness and height system of solar chimney are described. The 3-inside wall was made of concrete and 1-wall was made of glass. The two kinds of model experiment were performed. One was the varition of the 60cm, 90cm and 120cm of solar chimney, the other was the variation of the insulation thickness 10mm and 50mm and without insulation of outside wall of solar cimney. As the temperature difference between bottom and top expressed $1.7\sim2.9^{\circ}C$, air velocity measured $0.5\sim0.8m/s$ and ventilation rate was $194.4m^3/h$ in the case of the 120cm height of solar chimney, the respect of natural ventilation performance was superior to others cases in the first model experiment. Though the case of 120cm height of solar chimney was attached 50mm insulation the ventilation rate was not so much as the case of solar chimney was attached 10mm insulation. the temperature difference between bottom and top was the largest in the other cases. From this research, the natural ventilation performance of solar chimney was affected by not only height and insulation thickness of solar chimney but also wind velocity and directon.

연돌 효과를 이용한 태양열 굴뚝의 자연환기 성능에 관한 연구 (A Study on the Performance of Natural Ventilation of Solar Chimney Using Stack Effect)

  • 조성우;이재윤
    • 한국태양에너지학회 논문집
    • /
    • 제21권2호
    • /
    • pp.35-43
    • /
    • 2001
  • The results of numerical simulation on the performance of a solar chimney system in building are described. The inside surface temperature of four walls within the solar chimney arc calculated with solar radiation and outdoor temperature in summer. The air within the solar chimney is heated by conduction, convection and radiation. Air temperature distribution from the bottom to the top and outlet air temperature can be obtained by solving energy balance equation. Since the buoyance or stack effect is affected by temperature difference between the bottom and the top within the solar chimney. It is evaluated using inlet and outlet temperatures. It is expected that natural ventilation by the solar chimney of witch the height is 7.8m and the cross sectional area is $4.93m^2$ can provide about $6400m^3/h$ on sunny day.

  • PDF

자연형 태양 챔버 시스템의 성능 분석 (Performance Analysis of Passive Solar Chamber System)

  • 장향인;김병구;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.57-65
    • /
    • 2011
  • This study proposes a Passive Solar Chamber System (PSCS) as a passive method for reduction of building energy consumption. Through numerical analysis, the study quantitatively analyzes system performance and aims to provide foundational data for system design. For this purpose, the study configures different system operation modes seasonally and also computes thermal and ventilation performance of the system in accordance with design factors(solar radiation, air channel height and distance). System and ventilation efficiency increases along with increase in solar radiation and air channel distance; however, as the air channel height increases, the efficiencies showed a tendency to decrease. Upon installation of PSCS, an average of $98.23W/m^2$ of heat flux was introduced in the daytime for the month of January in comparison to walls with no PSCS installed. For the month of August, natural ventilation of $56.68m^3/h$ was shown to be supplied to the room.

자연형 태양 챔버 시스템의 계절별 성능 및 크기 결정 방법 (Sizing Method and Seasonal Performance of Passive Solar Chamber System)

  • 장향인;김병구;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.66-71
    • /
    • 2011
  • This study focused on the application of the Passive Solar Chamber System (PSCS) as proposed by a previous study. The seasonal performance and sizing method for the system were investigated for a feasibility of the PSCS in Korean climate. For seasonal performance, heat and ventilation performances of the PSCS were analyzed for the months of January and August. This study proposed a simple configuration method in which the designer can decide on the system size at the preliminary design stage by using system efficiency, overall heat transfer coefficient transmission, monthly solar radiation, highest and lowest temperatures. During weeks that require heating, the system showed to acquire a daily average heat amount of $860.28Wh/m^2$ day. For cooling periods, the system was computed to supply a daily average natural ventilation of $1,360.2m^3/day$ to the room. Moreover, proposed sizing method and the overall computation results showed a 6.04~7.24% error of assessment.

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

서울시 미세입자 특성 및 CMB 모델을 이용한 배출원 기여도 산정 (Characteristics of the Fine Particle and Source Apportionments using the CMB model in Seoul Area)

  • 강충민;이학성;강병욱;이상권;선우영
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.57-58
    • /
    • 2003
  • 대기중 입자상 물질은 대기중에서 발견될 수는 고체 및 액체상 물질로서 여러 가지 형태를 띄고 있다. 이러한 입자상 물질은 다양한 배출원인 자동차, 공장굴뚝, 가정난방 등과 같은 화석연료 연소시설과 토양 도로먼지, 건설현장, 해염입자 등과 같은 비 연소시설에서 배출되어 직접적으로 대기중으로 유입되기도 하며, 대기중 기체상 물질들이 태양광선 및 수증기의 존재하에서 화학반응을 일으켜 생성되는 이차입자도 있다. 미국 EPA (Environmental Production Agency)에서는 대기중 입자상 물질을 입경에 따라 두가지 형태인 PM$_{2.5}$와 PM$_{10}$으로 분류하였다. (중략)략)

  • PDF

바람에 의한 장대 Tower 구조물의 진동제어 방법 - 감쇠장치를 이용한 -

  • 변윤주;윤태양;송재준
    • 소음진동
    • /
    • 제3권4호
    • /
    • pp.293-299
    • /
    • 1993
  • 최근 토목, 건축재료 및 시공기술의 발전과 더불어 컴퓨터를 이용한 해석 기법의 개발, 경제규모의 확대, 주변환경과의 조화 및 미적감가의 끊임없는 추구는 구조물의 장대화, 연성화, 다양화는 물론 구조감쇠율의 감소 등을 가져옴으로서 바람에 의한 동적 거동의 영향이 증대되어 이에 대한 검토의 중요성이 크게 부각되기 시작하였다. 특히, 최근들어 활발히 계획, 공사중인 여러 현수교, 사장교 구조물 중 시공단계로서의 독립 tower, 발전소의 장대 굴뚝, 고층건물, 전망 tower, 공항 관제 탑 등이 좋은 예이다. 따라서 이들 구조물의 설계과정에서 제안된 여러형태의 진동 제어 방법중 수동 감쇠장치에 대하여 소개하기로 한다. 감쇠장치는 직접 외부에 부착 하는 강제 감쇠장치와 소량의 질량, 스프링과 감쇠장치들을 조합하여 부착하는 수동 감쇠장치가 있다. 수동감쇠장치는 소규모로서 유지보수가 거의 필요 없으며 외관의 변화가 거의 없고 저렴하다는 장점이 있다. 여러종류의 수동감쇠장치, 즉 TMD, IMD 그리고 TSD에 대한 개략적인 이론과 그 사용예에 대하여 설명하였다. 실험적 검증 및 실측결과 각 장치가 바람에 의해 야기되는 진동현상을 억제하는데 매우 유효한 것으로 판정되었고 또한 크기가 소규모일 뿐 아니라 유지보수가 거의 없으며 비용도 저렴하여 국내 건설 또는 건설예정인 유사구조물에도 많은 적용이 예상된다.

  • PDF