• Title/Summary/Keyword: 탄소량

Search Result 2,273, Processing Time 0.034 seconds

Ice-Nucleation Activity of Pseudomonas syringae Isolated in Korea (한국에서 분리한 Pseudomonas syringae의 빙핵활성)

  • Kim Yong Hwan;Kim Young Cheol;Cho Baik Ho;Kim Ki Chung
    • Korean Journal Plant Pathology
    • /
    • v.3 no.3
    • /
    • pp.180-186
    • /
    • 1987
  • Cell suspensions of two isolates of Pseudomonas syringae. PS8401 from sweet persimon and PS8402 from tea plant, were active in ice nucleation at -2.5 and $-3.8^{\circ}C$, respectively. Ice nucleation at those temperature was, using micropipette method, detected in suspensions ($10^8$ olony forming unit/ml of distilled water) of cells that had been grown on nutrient agar supplemented with $2.5\%$ glycerol. Using the same method, on the other hand, the freezing temperature of distilled water only was approx. $-21.8^{\circ}C$, and those of various plant saps including corn were lower than $-11.6^{\circ}C$. Corn seedlings sprayed with cell suspensions $(10^8\;cfu/ml)$ of nutrient broth) of PS8401 began to be damaged at $-2^{\circ}C$ and were almost completely damaged at $-4^{\circ}C$, whereas seedlings sprayed with nutrient broth only were not injured until the temperature down to $-9^{\circ}C$. Amounts of frost damage measured 48 hr after application of PS8401 suspensions increased as applied bacterial cell densities were increased. Ice-nucleation activity of the cell suspensions in vitro increased with increasing the number of cells in suspension. The activity also affected by growth-medium composition or growth-temperature. Ice nucleation thus occured at -4.0, -4.4 and $-7.2^{\circ}C$ in suspensions $(10^2\;cfu/ml)$ of PS8401 that had been grown at$25\%$ nutrient agar with $2.5\%$ glycerol, nutrient agar with $2.5\%$ glucose and nutrient agar only, respectively, and occured at -4.0 and $-7.6^{\circ}C$ in suspensions $(10^2\;cfu/ml)$ of PS8401 hat had been grown on nutrient agar with $2.5\%$ glycerol at $15\~25^{\circ}C$ and $30^{\circ}C$, respectively.

  • PDF

Causes of Childhood Injuries Observed at the Emergency Rooms of Five Hospitals in Taegu (대구시내 종합병원 응급실에 찾아온 소아사고 환아의 사고원인)

  • Park, Jung-Han;Bae, Yeong-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.224-237
    • /
    • 1988
  • To determine the causes of and related factors to childhood injuries, the emergency room records and inpatient medical records were reviewed for 4,849 injured children out of 15,790 pediatric patients(<15 years old) who visited the emergency rooms of 3 university hospitals and 2 general hospitals in Taegu from 1 January to 31 December 1987. Out of total injured children, 54.675 were 3-8 years old and the male to female ratio of the total injured children was about 2:1. The leading causes of injury were falls and slips (29.1%) and traffic accident(28.2%). The frequency of injury was higher in May-October than the rest of months and 51.6% of the injuries occurred between 15 and 20 o'clock. Falls and slips took place most frequently at the stairway(25.7%). The most common interpersonal violence was inflicted injuries(85.6%) and there were 11 child rapes. Dog bites accounted for 67.6% of all biting injuries and it occured 2.9 times more in male than in female. CO intoxication was the most common cause of poisoning (45.3%) and scalding accounted for 85.2% of all burns. Common places of drownings were river (32.2%), swimming pool (22.6%) and construction site(19.3%). To prevent childhood injuries, it is recommended to eliminate the hazardous environmental factors, to provide safe playgrounds, to educate the children for safety from kindergarten and the general public through mass communication, to establish a strict safety standard for houses, public buildings and facilities, and playgrounds.

  • PDF

Uptake and Recovery of Urea-15N Blended with Different Rates of Composted Manure (퇴비의 혼합 시비율에 따른 Urea-15N의 이용율 및 회수율)

  • Ro, Hee-Myong;Choi, Woo-Jung;Yun, Seok-In
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.6
    • /
    • pp.376-383
    • /
    • 2003
  • To utilize composts more efficiently, combining composts with fertilizer to meet crop requirements is an appealing alternative. A pot experiment was conducted to study the effect of application rate of composted pig manure blended with fertilizer on the availability and loss of fertilizer-N. Chinese cabbage (Brassica campestris L. cv. Samjin) plants were cultivated for 30 and 60 days. 15N-Labeled urea ($5.24\;^{15}N\;atom\;%$) was added to soil at $450mg\;N\;kg^{-1}$, and unlabeled compost ($0.37\;^{15}N\;atom\;%$) was added at 0, 200, 400, and $600mg\;N\;kg^{-1}$. The amount of plant-N derived from urea was not affected by compost application at rate of $200mg\;N\;kg^{-1}$. However, compost application at 400 and $600mg\;N\;kg^{-1}$ significantly (P<0.05) increased plant assimilation of N from urea irrespective of sampling time, probably because of physicochemical changes in the soil properties allowing urea-N to be assimilated more efficiently. The amount of immobilized urea-N increased with increasing rate of compost application at both growth periods, as the results of increased microbial activities using organic C in the compost. Total recovery of urea-N (as percentage of added N) by Chinese cabbage and soil also increased with increasing rate of compost from 71.5 to 95.6% and from 67.0 to 88.2% at the 30- and 60-days of growth, respectively. These results suggest that increasing rate of compost blending increases plant uptake of fertilizer-N and enhances immobilization of fertilizer-N, which leads to decrease in loss of fertilizer-N. However, information about the fate of immobilized N during future crop cultivation is necessary to verify long-term effect of compost blending.

Analysis of Terpenoids as Volatile Compound Released During the Drying Process of Cryptomeria japonica (삼나무 건조 중 발생하는 휘발성 유기화합물 Terpenoids의 분석)

  • Lee, Su-Yeon;Gwak, Ki-Seob;Kim, Seon-Hong;Lee, Jun-Jae;Yeo, Hwan-Myeong;Choi, In-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.242-250
    • /
    • 2010
  • The aim of this study was to investigate the terpenoids of Total Volatile Organic Compounds (VOCs) released during drying of Cryptomeria japonica using the thermal extractor (TE). Considering the drying process of C. japonica, temperatures of TE were set at $27^{\circ}C$, $60^{\circ}C$, $80^{\circ}C$, $100^{\circ}C$, and $120^{\circ}C$, respectively. As the result, the emission factors of VOCs and terpenoids were increased as temperature increased. The amount of terpenoids included in VOCs emission factors were 87.5%, 81.6%, 83.6%, 90.1%, and 97.3% depending on above temperatures, respectively. Especially at$100^{\circ}C$ and $120^{\circ}C$, the amount of terpenoids were measured more than 90%. ${\delta}$-cadinene was the highest yield at each temperature and 32 types of terpenoids were collected. Emitted terpenoids were classified into the sesquiterpene group which consists of 15 carbon sources. These 32 sesquiterpenes were used for determining the useful bioactivity such as antifungal activity by the agar dilution. As the result, they showed the antifungal activity against Trichophyton rubrum, Trichophyton mentagrophytes, Microsporum gypseum. The 5,000 ppm concentration of terpenoids showed a strong activity with 100% against the 3 fungi. At the 1,000 ppm concentration of terpenoids, the antifungal activities against three fungi were 95.2%, 98.7%, and 97.3%, and their activities were a little inhibited at 100 ppm concentration.

Effect of Heating by Nano-Carbon Fiber Infrared Lamps on Growth and Vase Life of Cut Roses and Heating Cost (나노탄소섬유 적외선등 난방이 절화장미의 생육과 수명 및 난방비에 미치는 영향)

  • Lim, Mi-Young;Ko, Chung-Ho;Son, Moon-Sook;Lee, Sang-Bok;Kim, Gil-Ju;Kim, Byung-Soo;Kim, Young-Bok;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The greatest and major cost for cut rose production during winter seasons in Korea is cost of heating the greenhouse. A study was conducted on a cost-efficient heating system to reduce expenses of cut rose growers in times of high energy prices. An infrared heating system utilizing radiant energy has an obvious advantage over other heating methods in that the energy is first used to raise temperatures of plants and other objects and subsequently that of the atmosphere, resulting in faster reaching to desired plant temperatures at a reduced heating cost. In this study the heating effect and heating cost saving of a nano-carbon fiber infrared heating system (NCFIHS) installed in cut rose greenhouses in Gimhae, Gyeongnam Province were analyzed comparatively. In addition growth, quality, and vase life of 'Orange Fresh' roses grown in greenhouses heated by NCFIHS against those grown in greenhouses heated by so called an electrical heating system. In greenhouses with a NCFlHS with a set point air temperature of $20^{\circ}C$, plant temperature was maintained at $1{\sim}2^{\circ}C$ higher than the air temperature, and temperatures of growing bed surface and root zone were maintained at $17{\sim}19^{\circ}C$ throughout cold winter nights. The cost for heating in NCFIHS was about 25 and 51% of that of an electrical heating system and a hot water heating system heated by petroleum, respectively. Growth of roses harvested in greenhouses with a NCFIHS was similar to those grown in greenhouses with an electrical heating system. However, cut roses with more intense petal and leaf colors and a longer vase life (fresh weight and amount of water uptake) were harvested in greenhouses with a NCFIHS as compared to those harvested in greenhouses with an electrical heating system.

The Measurement of $^{99m}Tc-DTPA$ Pulmonary Clearance in Normals, Asymptomatic Smokers and Diabetic Patients (정상 성인, 무증상 흡연자, 당뇨병 환자에서 $^{99m}Tc-DTPA$ 폐제거율의 측정)

  • Kim, In-Ju;Kim, Seong-Jang;Kim, Yong-Ki;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.266-275
    • /
    • 1998
  • Purpose: We measured pulmonary epithelial permeability by $^{99m}Tc-DTPA$ radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate $^{99m}Tc-DTPA$ radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. Materials and Methods: We performed $^{99m}Tc-DTPA$ radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) was calculated, then compared with the result of chest radiography and pulmonary function test. Results: Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiopathy were significantly older (p<0.05). The $T_{1/2}$ of normal subjects and asymptomatic smokers were significantly different ($65.2{\pm}23.7min$ vs $39.6{\pm}9.8min$, p<0.05). For diabetic patients with microangiopathy, the $T_{1/2}$ was $90.5{\pm}46.5min$ and significantly delayed when compared with those of normals and asymptomatic smokers (p<0.05). However, the $T_{1/2}$ of diabetic patients without microangiopathy, $70.0{\pm}12.7min$, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the $T_{1/2}$ and spirometric parameters including DLco, FVC, $FEV_1,\;FEV_1/FVC$ (%) and $FEF_{25-75%}$ in all subjects, and between the $T_{1/2}$ and duration of diabetes ;in diabetic patients. Conclusion: Eventhough the influence of age can't be excluded, delayed $^{99m}Tc-DTPA$ clearance half-time ($T_{1/2}$) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy.

  • PDF

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Suggestion for Technology Development and Commercialization Strategy of CO2 Capture and Storage in Korea (한국 이산화탄소 포집 및 저장 기술개발 및 상용화 추진 전략 제안)

  • Kwon, Yi Kyun;Shinn, Young Jae
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.381-392
    • /
    • 2018
  • This study examines strategies and implementation plans for commercializing $CO_2$ capture and storage, which is an effective method to achieve the national goal of reducing greenhouse gas. In order to secure cost-efficient business model of $CO_2$ capture and storage, we propose four key strategies, including 1) urgent need to select a large-scale storage site and to estimate realistic storage capacity, 2) minimization of source-to-sink distance, 3) cost-effectiveness through technology innovation, and 4) policy implementation to secure public interest and to encourage private sector participation. Based on these strategies, the implementation plans must be designed for enabling $CO_2$ capture and storage to be commercialized until 2030. It is desirable to make those plans in which large-scale demonstration and subsequent commercial projects share a single storage site. In addition, the plans must be able to deliver step-wised targets and assessment processes to decide if the project will move to the next stage or not. The main target of stage 1 (2019 ~ 2021) is that the large-scale storage site will be selected and post-combustion capture technology will be upgraded and commercialized. The site selection, which is prerequisite to forward to the next stage, will be made through exploratory drilling and investigation for candidate sites. The commercial-scale applicability of the capture technology must be ensured at this stage. Stage 2 (2022 ~ 2025) aims design and construction of facility and infrastructure for successful large-scale demonstration (million tons of $CO_2$ per year), i.e., large-scale $CO_2$ capture, transportation, and storage. Based on the achievement of the demonstration project and the maturity of carbon market at the end of stage 2, it is necessary to decide whether to enter commercialization of $CO_2$ capture and storage. If the commercialization project is decided, it will be possible to capture and storage 4 million tons of $CO_2$ per year by the private sector in stage 3 (2026 ~ 2030). The existing facility, infrastructure, and capture plant will be upgraded and supplemented, which allows the commercialization project to be cost-effective.

Characteristic Properties of Fucoidan Sulfate Purified from Gompi, Ecklonia stolonifera (곰피에서 정제한 Fucoidan Sulfate의 특성)

  • Lee, Hong-Soo;Jin, Sung-Hyun;Kim, Hee-Sook;Ryu, Byung-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.716-723
    • /
    • 1995
  • The fucoidan purified from Korean brown seaweed, Ecklonia stolonifera was characterized on molecular structure and blood anticoagulant activities. Extraction was conducted at $100^{\circ}C$ with water and repeated twice. The crude fucodian was 151.1g out of 20.0 kg of Ecklonia stolonifera. The Fucoidan-1, which was purified from crude fucoidan using calcium chloride and cetyl pyridium chloride (CPC), was 35.2% against crude fucoidan. Fucoidan-5 was obtained approximately 28.1% from Fucoidan-1 through DEAE-Toyopearl 650 M ion-exchange column chromatography and showed one band by cellulose acetate electrophoresis. The molecular weight of Fucoidan-5 was estimated to be about 21,000∼23,000 dalton by Sephacryl S-300 gel filtration chromatography. Fucoidan-5 consists of 35.7% of fucose and 4.3% of galactose and the molar ratio of fucose and sulfate was about one to one. IR spectrum of Fucoidan-5 showed absorption at $1240\;cm^{-1}\;and\;850\;cm^{-1}$ and specific rotation value, $[\alpha]$, was $[\alpha]$. These results suggests that the sulfate maybe bind at $C_{4}$ carbon on ${\alpha}-L-fucose$. Gas chromatograph of methyl alditol acetate revealed that Fucoidan-5 is a fucose containing sulfated polysaccharide with $({\alpha}l-2)\;or\;({\alpha}l-2)$ glycosidic linkage. Anti-thrombin activity of the Fucoidan-5 was estimated as 1.4 time stronger than heparin. From above results, the purification methods using CPC and ion exchange chromatography is effective tools for obtaining highly purified fucoidan from Gompi, Ecklonia stolonifera.

  • PDF

Importance of Carbon Monoxide Transfer Coefficient (KCO) Interpretation in Patients with Airflow Limitation (기류제한 환자의 일산화탄소확산능 해석에서 폐용적 보정의 의의)

  • Seo, Yong Woo;Choi, Won-Il;Lee, Jeong Eun;Park, Hun Pyo;Ko, Sung Min;Won, Kyoung Sook;Keum, Dong Yoon;Lee, Mi-Young;Jeon, Young June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.374-379
    • /
    • 2005
  • Background : The single-breath carbon monoxide diffusion capacity (DLCO) and the per unit alveolar volume (KCO; $D_LCO/VA$) gave discordant values when there was an abnormal alveolar volume (VA). However, the clinical significance of the discordant values in patients with airflow limitation has not been examined. This study investigated the $D_LCO$ and KCO changes after improving the airflow limitation. Methods : The baseline $D_LCO$ and KCO with lung volume were measured in patients with an airflow obstruction. The effective alveolar volume was measured using the single-breath $CH_4$ dilution method. The patients divided into two groups according to the baseline values: (1) increased KCO in comparison with the $D_LCO$ (high discordance) (2) decreased or not increased KCO in comparison with the $D_LCO$ (low discordance). The diffusion capacity and lung volume were measured after treatment. Results : There was no significant difference in the baseline lung volumes including the $FEV_1$ and FVC between the two groups. The $FEV_1$ and FVC were significantly increased in the high discordance group compared with the low discordance group after treating the airflow limitation. The $D_LCO$ and alveolar volume were significant higher in the high discordance group compared with the low discordance group while the TLC was not. Conclusion : The discordance between the $D_LCO$ and KCO could be translated into an airflow reversibility in patients with an airflow limitation.