• Title/Summary/Keyword: 탄성 모듈 결찰

Search Result 3, Processing Time 0.015 seconds

THE EFFECT OF LIGATION METHOD ON THE FRICTIONAL FORGE BETWEEN ORTHODONTIC BRACKET AND ARCHWIRE (결찰양식이 교정용 브라켓과 교정선 사이의 마찰력에 미치는 영향)

  • Shin, Hyun-Jeong;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.813-823
    • /
    • 1998
  • The frictional force has been considered as an harmful factor in an active unit where tooth movement occurs, but as an advantageous factor in anchor unit that resist tooth movement. That is, efficient tooth movement is planned by using ligation methods that have low levels of bracket-wire frictional force and the anchorage control can be achieved by using ligation methods that have high levels of bracket-wire frictional force that result in binding of the bracket accompanied by little or no tooth movement. The purpose of this study was to evaluate the frictional force generated between bracket and wire in accordance with the methods of ligation, the material of ligation and the passage of time under artificial saliva. Tested were 0.017x0.022 inch stainless steel wires in standard edgewise twin brackets for upper central incisors in a 0.018-inch slot. The wires were ligated into the brackets with elastomeric modules and stainless steel ligatures. Whole tie, half tie, twisting tie and double overlay tie were done with elastomeric modules. With 0.009-inch stainless steel ligature whole tie and half tie were done by needle holder and whole tie by ligature tying plier. With 0.012-inch stainless steel ligature whole ties were done by needle holder. Whole tie groups of elastomeric module were kept in artificial saliva bath at $37^{\circ}C$ for 28 days. The frictional force was recorded by means of an Instron universial testing instrument (4202 INSTRON, Instron Co., U.S.A.) at initial, 7, 14, 21, and 28 days. The results for ligated samples in a simulated oral environment revealed the fellowing : ${\cdot}$In elastomeric module whole tie, 28 days group was significantly greater mean static frictional force than any other group but there were no significant differences among any other group (p>0.05). ${\cdot}$Elastomeric module twisting ties were significantly greater mean static frictional forces than any other ligation method but there were no significant differences between twisting tie and double overlay tie (p>0.05). Twisting tie, double overlay tie, whole tie, half tie showed differences in decreasing order. ${\cdot}$Stainless steel half tie produced lower mean static frictional force than whole tie, ligation by ligature tying plier produced greater mean static frictional force than by needle holder and ligation with 0.012-inch stainless steel ligature produced greater mean static frictional force than with 0.009-inch stainless steel ligature (p<0.05). ${\cdot}$There were no significant differences between the mean static frictional forces of elastomeric whole tie and stainless steel whole tie (p>0.05).

  • PDF

Evaluation of frictional forces between orthodontic brackets and archwires (교정용 브라켓과 교정선 사이의 마찰력)

  • Jeong, Tae-Jong;Choie, Mok-Kyun
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.613-623
    • /
    • 2000
  • The purpose of this study was to amount of the frictional forces with the brackets and wires, ligation methods, dry/wet, offsets, interbracket distances, velocity and to compare them each other by different conditions. This study tested 0.018'x0.025' slot sized 8 types of orthodontic bracket systems and 0.016', 0.016'x0.022' sized stainless steel, NiTi, Cu-NiTi orthodontic wires. One cuspid bracket were positioned on the slide glass and archwire was engaged into bracket and ligated with elastomeric modules. The values of frictional forces were measured with the instron universal testing machine. The results were as follows; 1. Polycrystalline ceramic bracket had the highest mean frictional forces and followed and by ceramic reinforced plastic bracket, metal bracket, plastic bracket with metal slot, monocrystalline ceramic bracket, single bracket, self-ligating bracket, friction free bracket in descending order. The self-ligating bracket showed low frictional forces in the round wires and high frictional forces in the rectangular wires. 2. Stainless steel wires had the least frictional forces and followed by NiTi, Cu-NiTi wires in descending order. Round wires had lower frictional forces then that of rectangular wires. 3. The stainless steel ligation method had significantly greater mean frictional forces them the elastomeric module ligation method. 4. Artificial saliva statistically increased the frictional forces in stainless steel wire, NiTi wire and Cu-NiTi wire. 5. There was a statistically significant difference with offset change 6. There was no statistically significant difference with interbracket distance in stainless steel wires but a significant difference in NiTi wires as the interbracket was decreased. 7 There was no statistically significant difference with velocity change. From the above findings, self-ligating bracket, stainless steel wires and the elastomeric module ligation method might be effective than any other materials to reduce the frictional forces in the orthodontic treatment and can be correlated to clinical situations seen in orthodontic patient care.

  • PDF

Effect of estrogen on growth hormone receptor expression of human periodontal ligament cell line (치주인대세포 배양에서 estrogen이 growth hormone receptor의 발현유도에 미치는 영향)

  • Hong, Sung-Gyu;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.441-452
    • /
    • 2000
  • The present studies were performed to investigate the interaction of $17{\beta}$-estradiol and human growth hormone(hGH) on the proliferation of human periodontal ligament(WDL) cell. The independent effects of $17{\beta}$ estradiol and hGH on hPDL cell proliferation were investigated and the effects of hGH on hPDL cell proliferation after $17{\beta}$-estradiol pre-treatment were also investigated. Lastly, the change of hGH receptor expression in hPDL cell after $17{\beta}$-estradiol pre-treatment were investigated. The obtained results were as follows; 1. The treatment of $17{\beta}$-estradiol or hGH had no significant effects on hPDL cell proliferation. 2. After pre-treatment of $17{\beta}$-estradiol, hGH stimulated the proliferation of the hPDL cell, regardless of hHG concentration. 3. Although there was not hGH receptor in the hPDL cell, hGH receptors were expressed in hPDL cell after more than 6 hours pre-treatment of $17{\beta}$-estradiol. 4. The effect of hGH on hPDL cell proliferation was related to the hGH receptor expression. $17{\beta}$-estradiol pre-treaaent contributed to the hGH effects on the hPDL cell by stimulating hGHR expression.

  • PDF