• Title/Summary/Keyword: 탄성초음파

Search Result 217, Processing Time 0.028 seconds

An Experimental Study on Elastic Properties of Rice Straw Ash Concrete (볏짚재 콘크리트의 탄성특성에 관한 실험적 연구)

  • 성찬용
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.1
    • /
    • pp.92-98
    • /
    • 2000
  • This study is performed to evaluate the elastic properties of rice straw ash concrete using reices straw ash, cement, natural sand, gravel, and superplasticizer. The following conclusions are drawn ; The ultrasonic pulse velicity is in the range of 4,084 ~4,336m/s , which has showed about the same compared to that of the normla cement concrete. The highest ultrasonic pulse velocity is showed by 5 % rice straw ash filled rice straw ash concrete. The dynamic and static modulus of elasticity is in the range of 294 $\times$10$^3$ ~347 $\times$ 10$^3$ and 266 $\times$10$^3$~328 $\times$10$^3$kgf/㎤ , respectively. It is showed about the same compared to that of the normal cement concrete. The Poisson's number of rice straw ash concrete is less than that of the normal cement concrete.

  • PDF

Design and realization of hyperbolic elastic metamaterial for ultrasonic sub-wavelength resolution (탄성 초음파 회절한계 극복을 위한 하이퍼볼릭 탄성 메타물질의 설계와 구현)

  • Oh, Joo Hwan;Ahn, Young Kwan;Seung, Hong Min;Kim, Yoon Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.743-744
    • /
    • 2014
  • Hyperbolic metamaterials in which waves can only propagate through the radial direction have achieved much attention these days due to their capability of sub-wavelength resolution. In this work, the realization and optimization of hyperbolic elastic metamaterials are mainly studied. To obtain a new hyperbolic elastic metamaterial, a specially-engineered mass-spring system is introduced. Based on the mass-spring system, the hyperbolic elastic metamaterials are proposed and realized. In addition, the sub-wavelength resolution of the proposed hyperbolic elastic metamaterial is verified by ultrasonic elastic wave experiments. For the experiments, specially-designed magnetostrictive patch transducers are developed to realize two sub-wavelength elastic wave sources. Furthermore, the proposed hyperbolic elastic metamaterial is optimized to maximize its operating frequency ranges by the topology optimization method.

  • PDF

A Study on Motion Characteristics of the Ultrasonic Transporting System according to the change of Flexural Beam Shape (Flexural Beam의 형태 변화에 따른 초음파 이송시스템의 동작특성에 관한 연구)

  • 정상화;신병수;차경래
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.696-699
    • /
    • 2003
  • In the semiconductor and the optical industry a new transport system which can replace the conventional sliding system is required. There systems are driven by magnetic field and conveyer belt. The magnetic field damages semiconductor and contact force scratches the optical lens. The ultrasonic wave driven system can solve these problem. In this paper, the object transport system using the excitation of ultrasonic wave is proposed. The experiments for finding the optimal excitation frequency, finding phase-difference between two ultrasonic wave generators are performed. The relationship of transporting speed according to the change of flexural beam shape is verified and the system performance for practical use is evaluated.

  • PDF

A Study on the Stiffness Estimation in Soft Tissue Using Speckle Brightness Variance Tracking (초음파 의료영상에서 스페클의 시간적 밝기 변화를 이용한 연조직의 stiffness를 추정하는 방법에 대한 연구)

  • 안동기;박정만;권성재;정목근
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.141-149
    • /
    • 2003
  • This paper proposes a method of measuring and imaging the stiffness of human soft tissue to diagnose cancers or tumors which have been difficult to detect in ultrasound B-mode imaging systems. To measure the soft tissue stiffness, sinusoidal vibrations are applied to it, and the magnitude of its mechanical vibration is determined by estimating the temporal variation of speckle pattern brightness in ultrasound B-mode images. It is verified by simulation and experiment that the proposed method can estimate the relative tissue stiffness from B-mode images with a relatively small amount of computation.

Nondestructive Evaluation for Thermally Degraded Co-base Superalloy by Scanning Acoustic Microscope (초음파현미경을 이용한 Co 기 초내열 합금 열화재의 비파괴평가)

  • Kim, Chung-Seok;Song, Jin-Hun;Kwon, Sook-In;Lim, Jea-Seang;Park, Ik-Keun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.336-341
    • /
    • 2004
  • This research investigates the feasibility of ultrasonic microscope for nondestructive assessment of thermal degradation in artificially aged commercial Co-base superalloy, FSX414. This alloy has been used for high temperature structure applications such as stationary gas turbine blade and nozzle chamber in fossil plant. Microstructural change was found that the fine carbides became coarser and spheroidized in matrix as aging time increased. The leaky surface acoustic wave velocity gradually decreases by a maximum of 4.7% with increasing aging time up to 4,000hours. However, the longitudinal wave velocity has a little change. Also, it has a good correlation between leaky surface acoustic wave velocity and Vickers hardness. Consequently, LSAW can be used to examine the degree of degradation in thermally aged Co-base superalloy.

  • PDF

Adaptive quantization for effective data-rate reduction in ultrafast ultrasound imaging (초고속 초음파 영상의 효과적인 데이터율 저감을 위한 적응 양자화)

  • Doyoung Jang;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.422-428
    • /
    • 2023
  • Ultrafast ultrasound imaging has been applied to various imaging approaches, including shear wave elastography, ultrafast Doppler, and super-resolution imaging. However, these methods are still challenging in real-time implementation for three Dimension (3D) or portable applications because of their massive data rate required. In this paper, we proposed an adaptive quantization method that effectively reduces the data rate of large Radio Frequency (RF) data. In soft tissue, ultrasound backscatter signals require a high dynamic range, and thus typical quantization used in the current systems uses the quantization level of 10 bits to 14 bits. To alleviate the quantization level to expand the application of ultrafast ultrasound imaging, this study proposed a depth-sectional quantization approach that reduces the quantization errors. For quantitative evaluation, Field II simulations, phantom experiments, and in vivo imaging were conducted and CNR, spatial resolution, and SSIM values were compared with the proposed method and fixed quantization method. We demonstrated that our proposed method is capable of effectively reducing the quantization level down to 3-bit while minimizing the image quality degradation.

Shear-wave elasticity imaging with axial sub-Nyquist sampling (축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법)

  • Woojin Oh;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.403-411
    • /
    • 2023
  • Functional ultrasound imaging, such as elasticity imaging and micro-blood flow Doppler imaging, enhances diagnostic capability by providing useful mechanical and functional information about tissues. However, the implementation of functional ultrasound imaging poses limitations such as the storage of vast amounts of data in Radio Frequency (RF) data acquisition and processing. In this paper, we propose a sub-Nyquist approach that reduces the amount of acquired axial samples for efficient shear-wave elasticity imaging. The proposed method acquires data at a sampling rate one-third lower than the conventional Nyquist sampling rate and tracks shear-wave signals through RF signals reconstructed using band-pass filtering-based interpolation. In this approach, the RF signal is assumed to have a fractional bandwidth of 67 %. To validate the approach, we reconstruct the shear-wave velocity images using shear-wave tracking data obtained by conventional and proposed approaches, and compare the group velocity, contrast-to-noise ratio, and structural similarity index measurement. We qualitatively and quantitatively demonstrate the potential of sub-Nyquist sampling-based shear-wave elasticity imaging, indicating that our approach could be practically useful in three-dimensional shear-wave elasticity imaging, where a massive amount of ultrasound data is required.

Nondestructive Evaluation of Advanced Ceramics by Means of Ultrasonic Velocity and a Micromechanics Model (초음파 속도와 미시역학 모델을 이용한 고급 세라믹스의 비파괴적 평가)

  • Jeong, Hyun-Jo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.90-100
    • /
    • 1994
  • Ultrasonic velocities are widely used in the investigation of material properties. In this paper, a micromechanics model and the ultrasonic velocity were used to develop a nondestructive method to determine the density variation due to porosity in structural SiC. The micromechanics model developed can consider the pore shape and orientation. The model also takes into account the interaction between pores so that it can be applied to the material with high porosity content. A contact pulse overlap method was used to measure the ultrasonic velocities of porous SiC samples, and there was a linear correlation between the velocity and density (or porosity). Using the model and the measured velocity, the bulk density can be easily calculated. The calculated density was in good agreement with that obtained by Archimedes' method.

  • PDF