• Title/Summary/Keyword: 탁도 제거

Search Result 250, Processing Time 0.032 seconds

후면 에미터 구조의 n-type 결정질 실리콘 태양전지 제작 및 최적화 연구

  • Tak, Seong-Ju;Kim, Yeong-Do;Park, Seong-Eun;Kim, Dong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.12.1-12.1
    • /
    • 2011
  • 최근 p-type 결정질 실리콘 태양전지의 광열화현상(light induced degradation)에 대한 관심이 높아지면서, 이를 해결하기 위한 많은 연구들이 수행되고 있다. 본 연구에서는 LID 현상을 원천적으로 제거 할수 있는 n-type 기판을 이용하여, 상업적으로 양산화 가능한 공정을 도입하고, 시뮬레이션을 통하여 고효율화 방안을 제시하고자 한다. 이를 위해 일반적인 p-type 결정질 실리콘 태양전지 제작 공정을 사용하여 알루미늄이 도핑된 후면 에미터 구조의 n-type 결정질 실리콘 태양전지를 제작하였으며, PC1D 시뮬레이션을 통해서 n+/n/p+구조의 n-type 결정질 실리콘 태양전지의 에너지 변환 효율 향상을 위한 방안을 제시하였다.

  • PDF

Barley Noodle Making by Vacuum Press (진공 탈기 압출법에 의한 보리 국수 제조)

  • Chang, Chang-Moon;Oh, Young-Taeg;Yoon, In-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.93-97
    • /
    • 1986
  • Dried barley moodle was made with the addition of gelatinized corn flour as binder by using piston type noodle piston press, in which the temperature was kept below the temperature of protein denaturation. The evacuation of air bubble from the dough strengthened the wet noodle strands and improved the cooking quality of the dry noodle. Although the binder was indispensable, the addition should be less than 20%, because the gelatinized corn flour increased the turbidity of the cooking water. Kneading with 3% solution of soy protein resulted in improvement of the noodle's cooking quality.

  • PDF

A Sliding-Mode Controller for Enhancement of Fast Dynamic Characteristic in Three-Phase Boost Rectifiers (3상 승압형 정류기에서 과도상태 응답특성의 향상을 위한 슬라이딩 모드 제어기)

  • Kim, Ju-hye;Jou, Sung-Tak;Choi, Dae-Keun;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.101-102
    • /
    • 2012
  • 본 논문에서는 3상 승압형 정류기를 위한 슬라이딩모드 기반의 센서리스 직접전력제어방법을 제안한다. 공간벡터변조방식을 이용한 직접전력제어기법은 히스테리시스 제어기를 사용한 방법에 비해 스위칭 주파수가 일정하게 유지되어 시스템 안정성은 향상되지만, 응답속도가 떨어지는 단점이 있다. 제안하는 방법은 센서리스 기법을 이용하여 전압 센서를 제거하였고, 슬라이딩모드 제어기를 이용하여 시스템의 응답속도를 개선하였다. 3상 승압형 정류기의 시뮬레이션 결과를 통해 제안하는 제어기법의 타당성을 검증한다.

  • PDF

Application of Data Mining for Coagulant Dosage of Water Treatment Plants Corresponding to Input Conditions (원수조건에 따른 상수도 응집제 종류와 주입량 결정을 위한 데이터 마이닝 적용)

  • 배현;김성신;최대원;이승태;김예진
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.223-226
    • /
    • 2004
  • 본 논문은 정수장에서 사용하는 응집제의 종류와 주입량을 결정하기 위한 시스템 개발에 관한 내용이다. 정수장은 여러 단위 처리장으로 구성되며, 탁도와 색도를 제거하기 위하여 혼화지에서 응집제를 주입하여 침전을 시킨다. 현재까지 응집제 결정을 위해 Jar-test를 이용하였는데, 이 방법은 사람의 주관적인 판단에 의존하므로 실험 오차가 발생할 수 있다. 특히 정수장의 자동화를 위한 시스템 개발에서 가장 큰 걸림돌로 작용하고 있다. 본 논문은 이러한 문제점을 해결하기 위하여 데이터 마이닝 기법 등을 이용한 응집제 종류와 양을 결정하는 제어기를 개발하였다.

  • PDF

Foreign Bodies Lodged in Bronchus and Esophagus for a Long Period (장기간 체류한 기관지 및 식도이물)

  • 성창섭;조태환;최상규;탁기식;이웅렬;배홍갑
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.5.1-5
    • /
    • 1982
  • Foreign bodies in airway and food passage commonly occur by accident, and in most cases they get removed without delay. But sometimes, because of patron's ignorance and lack of physician's eagerness in examination, the possible presence of foreign body is overlooked. And patient with subsequent symptoms is transferred to ENT department after managed by non-otolaryngologist for a long time. We had experienced and studied two cases of foreign bodies which had been lodged for a long period.

  • PDF

Development and Application of Static Mixer (스태틱 믹서 개발 및 응용)

  • Yang, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.506-513
    • /
    • 2007
  • One of the most widely used static mixers is Sulzer type mixer. However the structure of the element is so complicated that the mixing efficiency is better than others, whereas the pressure drop is larger than the others. Therefore new elements are necessary to reduce the pressure drop and to minimize the decrease of the mixing efficiency compared with the Sulzer ones. The objectives of this study are to develop new static mixer and to perform the experimental investigation in order to evaluate the performance of the new one, and to investigate the applicability of the one in an inline coagulant mixing system for water treatment, The pressure drops of the new static mixer elements were about 4-12% lower than that of the Sulzer SMX one, and the mixing efficiency of the Sulzer SMX one was about 2-5% higher than that of the new ones. The inline coagulant mixing system with a new static mixer element performed significantly better than the traditional mechanical mixing system for turbidity removal.

A Study on the Removal of Cu Impurity on Si Substrate and Mechanism Using Remote Hydrogen Plasma (리모트 수소 플라즈마를 이용한 Si 기판 위의 Cu 불순물 제거)

  • Lee, Jong-Mu;Jeon, Hyeong-Tak;Park, Myeong-Gu;An, Tae-Hang
    • Korean Journal of Materials Research
    • /
    • v.6 no.8
    • /
    • pp.817-824
    • /
    • 1996
  • Removal of Cu impurities on Si substrates using remote H-plasma was investigated. Si substrates were intentionally contaminated by 1ppm ${CuCI}_{2}$, standard chemical solution. To determine the optimal process condition, remote H-plasma cleaning was conducted varying the parameters of rf power, cleaning time and remoteness(the distance between the center of plasma and the surface of Si substrate). After remote H-plasma cleaning was conducted, Si surfaces were analysed by TXRF(total x-ray reflection fluorescence) and AFM(atomic force microscope). The concentration of Cu impurity was reduced by more than a factor of 10 and its RMS roughness was improved by more than 30% after remote H-plasma cleaning. TXRF analysis results show that remote H-plasma cleaning is effective in eliminating Cu impurity on Si surface when it is performed under the optimal process condition. AFM analysis results also verifies that remote H-plasma cleaning makes no damage to the Si surface. The deposition mechanism of Cu impurity may be explained by the redox potential(oxidation-reduction reaction potential) theory. Based on the XPS analysis results we could draw a conclusion that Cu impurities on the Si substrate are removed together with the oxide by a "lift-off" mechanism when the chemical oxide( which forms when Cu ions are adsorbed on the Si surface) is etched off by reactive hydrogen atoms.gen atoms.

  • PDF

Effect of Pre-chlorine and Polyamine Dosing for Microcystis sp. Bloomed Water on Drinking Water Treatment Processes : Particle Matter Distribution (Microcystis sp.로 수화된 상수원수에 전염소 및 폴리아민 투입이 정수처리에 미치는 영향 : 입자상 물질 분포)

  • Son, Hee-Jong;Kim, Sang-Goo;Lee, Jeong-Kyu;Hwang, Young-Do;Ryu, Dong-Choon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.556-560
    • /
    • 2017
  • This research carried out to evaluate the disadvantage of pre-chlorination and the effect of polyamine as coagulant aids for treating the blooming water with Microcystis sp.. Pre-chlorination on blooming water makes the colony of Microcystis sp. to the smaller size. Coagulation with polyamine advanced treatment efficiency not only turbidity but also particulate matters especially less then $5{\mu}m$ size for the blooming water compared with using alum alone. Particle count was more sensitive than turbidity on water quality management of settlement and filtrate.

Treatment of Recycling Wastewater of Aquaculture Using DynaSand Filter( I ) (상향류식 연속역세여과를 이용한 양어장 순환수 재이용(I))

  • 박종호;김이오;황규덕;황금희;조규석;김동식
    • Journal of Aquaculture
    • /
    • v.15 no.2
    • /
    • pp.87-93
    • /
    • 2002
  • To improve the efficiency of biological filters used for treating recycled wastewater of aquaculture, the conventional and advanced DynaSand Filters were tested. Applying the fluid mechanics and physical chemistry theories to wastewater treatment plant, the advanced filter focuses on detection of wastewater characteristics and automatic operation of DynaSand Filter to improve backwashing, oxygen transport, turbidity removal and continuous head loss. The Filter removes COD, ammonia, and suspended solids (SS), the major pollutants in aquaculture wastewater. The total volume of the DynaSand Filter is 70 L, while the working volume is 35 L per cycle. The removal efficiency of the advanced DynaSand Filter is 71 % for SS (as against 55 % for the conventional filter), 84 % for ammonia, 85 % for T-P, and 88 % for SRP.

Development of customized and energy-saving process for wastewater reuse utilizing UF/NF membrane (UF/NF 분리막을 활용한 수요자 맞춤형 / 에너지 절약형 재이용수 공정기술 개발)

  • Hong, Min;Hwang, Hyun-Seob;Park, Ock-Kwon;Kim, Yong-Lim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.712-712
    • /
    • 2012
  • 하 폐수 처리방류수를 물리적, 화학적 그리고 생물학적 기술을 이용하여 처리한 후 재활용수로 이용하고자 하는 새로운 노력들이 진행되고 있지만 국내의 경우 방류수 재활용 기술과 처리수의 재이용에 대한 평가기술이 선진국에 비해 초기 단계에 있어 이 분야에 대한 적극적인 기술개발이 요구된다. 막 분리 기술을 이용한 처리 수는 소독 등의 추가적인 처리 없이 살수용수나 수경용수로 이용이 가능하며, 잔류염소를 유지시킬 경우 화장실 세정용수로의 이용도 가능하며, 또한 후처리 기술을 조합하면 고급 공업용수 등으로 사용가능하므로 선진기술로서 수요조건에 맞게 전 후 처리를 조합한 수요자 맞춤형 재이용수 공정기술을 개발할 필요가 있다. 이에 효율적인 하 폐수 재이용을 이용하여 농업용수(축산 음용수, 첨단 수출원예용수, 첨단 농업용수, 농산업 클러스터 복합 곡물 용수), 원예용수(원예단지), 공업용수 등의 다양한 용도에 활용 가능한 수요자 맞춤형 모듈 및 공정 개발을 수행하였다. 개발된 공정은 AOP 및 막 세정 시스템을 이용한 새로운 공정으로, AOP 시스템은 전기 이온 모듈을 통해 OH 라디칼을 생성 및 염분 제거 효율을 극대화 하여 오염 물질을 산화시키는 공정이며, FDA 시스템은 탁도가 높은 원수가 과다 유입 될 경우 후단 여과 막의 부하를 줄이는 역할을 하며, 부유 물질을 여과 시킨다. 막 세정 시스템은 미세 입자를 구성된 기포를 이용하여 눈에 보이지 않는 곳 까지 세척하며, 살균 작용을 하며, 분리 막의 성능을 증대 시킨다. 이어 UF 분리 막 시스템은 원수의 미세불순물, 박테리아, 스케일 물질 등을 제거하며, NF 시스템을 통하여 미립자, 박테리아 유기 화합물 및 2가 염 제거를 하여 재이용수를 생산하는 공정을 개발하였다. 개발된 수요자 맞춤형 공정은 하수 재이용 기술의 이용 목적 및 수요자별로 맞춤형으로 운영이 가능하며, 개발된 세척 기술은 분리 막 세정 유지관리비 및 에너지를 저감 할 수 있으며, 현장 적용의 실증화 과정을 거쳐 공정 기술을 신뢰도를 향상하고, 보유 기술을 수요자 맞춤형으로 업그레이드함으로써 기술의 경쟁력 및 고품질의 하수 재이용 기술의 새로운 방향을 제시 할 수 있을 것으로 판단된다.

  • PDF