• Title/Summary/Keyword: 탁도 제거

Search Result 250, Processing Time 0.031 seconds

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Ultrafiltration and Photocatalyst: 3. Effect of Organic Matters at $N_2$ Back-flushing (세라믹 한외여과 및 광촉매 혼성공정에 의한 고탁도 원수의 고도정수처리: 3. 질소 역세척 시 유기물의 영향)

  • Park, Jin Yong;Han, Ji Soo
    • Membrane Journal
    • /
    • v.22 no.3
    • /
    • pp.171-177
    • /
    • 2012
  • Effect of humic acid (HA), photo-oxidation and adsorption with periodic $N_2$ back-flushing was investigated in hybrid process of ceramic ultrafiltration and photocatalyst for drinking water treatment. It was compared and investigated with the previous result at water back-flushing in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). As decreasing HA, $R_f$ decreased dramatically and J increased, and finally $V_T$ was the highest at HA 2 mg/L. As HA concentration increased from 2 to 10 mg/L, the membrane fouling resistance after 180 mins' operation ($R_{f,180}$) improved 0.8 times more than that of water back-flushing. Therefore, HA concentration should affect on the membrane fouling at $N_2$ back-flushing than water back-flushing. Turbidity treatment efficiencies were almost constant independent of HA concentration, but HA treatment efficiency was the maximum at HA 2 mg/L. This means that adsorption and photo-oxidation of photocatalyst beads could removed HA at HA 2 mg/L, but it was not enough at 4 mg/L. Beyond HA 6 mg/L, UF could effectively treat HA by thick cake layer on membrane surface and severe inner membrane fouling.

Changes in the Removal Efficiency of Total Phosphorus by the Basicity of Al(III) Coagulant (Al(III) 응집제의 염기도에 따른 총인 제거효율의 변화)

  • Han, Seung-Woo;Lee, Chul-Hee;Lee, Jae-Kwan;Kang, Lim-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.229-236
    • /
    • 2012
  • The analysis of Al (III) hydrolysis species with PACls prepared by different basicity showed that mononmeric Al species were reduced while precipitate Al species were increased with an increase in basicity for PACls. In the case of the PACl with 13.6% basicity, monomeric Al species were 81%, polymeric Al (III) species 19%, precipitate Al (III) species was 0%, as showing the dominant monomeric Al species. The PACl with 13.6% basicity showed above 80% of turbidity removal efficiency without any restabilization. In addition, the PACl with 13.6% basicity showed higher organic removal expressed by $UV_{254}$ which was caused by lower coagulation pH. The PACl containing the higher amount of monomeric Al species was the most beneficial for T-P and $PO_{4}-P$ removal.

Effect of Coagulated Flocs Broken by the Pressure Pump on Removal Rate and Membrane Fouling of Pressurized MF process (가압펌프에 의해 해체된 플럭이 가압식 막여과 공정의 제거효율 및 막오염에 미치는 영향)

  • Kim, Junhyun;Moon, Baeksu;Park, Jongsu;Cho, Yoonho;Kim, Jinho
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.460-468
    • /
    • 2013
  • This study reviewed optimum dosage rate of coagulant and ability to remove dissolved organic carbon without sedimentation in conventional water purification plant. It was confirmed that floc formated by pre-treatment process was broken by impeller of booster pump. Optimum dosage rate of coagulant was 4 mg/L (as PACl 17%) for floc formation through blend, coagulation and after passing through the pump when turbidity of raw water was less than 10 NTU. And average removal rate of dissolved organic carbon was 43% at that time. Maximum removal rate of dissolved organic carbon was 48%, even though coagulation rate was increased gradually until 8 mg/L (as PACl 17%). So removal rate of dissolved organic carbon is not much improved even if dosage rage of coagulant increase. TMP of PVDF (polyvinylidene flouride) pressurized MF process without pre-treatment operated at 0.54 bar and TMP of PVDF pressurized MF process with pre-treatment operated at 0.41 bar.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of GAC Packing Fraction (세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 입상 활성탄 충전율에 의한 영향)

  • Park, Jin-Yong;Lee, Hyuk-Chan
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • In this study, we used hybrid module that was composed of packing granular activated carbon (GAC) between module inside and outside of ceramic microfiltration membrane for advanced drinking water treatment. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, synthetic water was prepared with humic acid and kaolin. Packing fraction of GAC was changed from 0 to 24.05% to see effect of packing fraction. As a result, changing curves of resistance of membrane fouling ($R_f$) and permeate flux (J) during 3 h operation were almost overlapped independent of packing fraction of GAC. Treatment efficiencies of turbidity were very high above 99.46% at all packing fractions of GAC. And treatment efficiency of NOM, which was measured by $UV_{254}$ absorbance, was the highest value of 99.43% at packing fraction of 24.05%. Then, we operated the hybrid process during 13 h at packing fraction of 24.05%. As a result, J was rapidly dropped according to increase of membrane fouling within initial 1 h of operation, and almost constant after 3 h. And treatment efficiencies of turbidity and NOM were stable and high values of 99.52% and 96.63%, respectively.

Characteristics of Goroshoe (Acer mono Max.) Sap with Different Collection Times After Ultra Filtration (한외여과 처리에 따른 채취시기별 고로쇠 수액의 품질특성)

  • Jeong, Su-Jeong;Lee, Chang-Hyeon;Kim, Hyun-Young;Hwang, In-Guk;Shin, Chang-Seob;Park, Eui-Seok;Lee, Jun-Soo;Jeong, Heon-Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.5
    • /
    • pp.753-758
    • /
    • 2011
  • We investigated the effects of ultra filtration (UF) of Goroshoe (Acer mono Max.) sap collected in March and April. The total bacteria and turbidity of the sap collected in April were higher than in March. However, after UF, the turbidity decreased and bacteria were not detected. The total acidity and total sugar of the sap collected in April were lower than that collected in March. After UF, total acidity and total sugar decreased slightly in sap from both of the collection times. The crude ash and mineral content of the sap collected in April were higher than in March. In particular, the calcium and potassium content of the sap collected in April were 166.38 and 29.47 mg/L, respectively, which was much higher than in March. Again, after UF, the crude ash and mineral content were decreased in the sap from both collection times. We concluded that UF of Goroshoe sap increased its quality regardless of collection time.

The Effect of Floating Wetland on Water Quality Improvement in a Eutrophic Lake (부유습지를 이용한 부영양수계 현장 수질개선 효과)

  • Park, Chae-Hong;Park, Myung-Hwan;Choi, Dong-Ho;Choi, Hyung-Joo;Lee, Joon-Heon;Lee, Myung-Hoon;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.116-127
    • /
    • 2013
  • At weekly intervals, we monitored continuous changes in water quality by constructed floating wetland equipped with the four different filter media (sponge, volcanic stone, activated carbon and magnesium hydroxide) in a eutrophic lake from March 2011 to May 2012. We also investigated phyto- and zooplankton communities both in the influent and the effluent water through the floating wetland. Over a 10-month time period, average turbidity (66%), suspended solids (79%) and chlorophyll-a (80%) concentrations were remarkably reduced in the effluent water compared to the influent (P<0.001). The average removal rates of $NO_2-N$ and $NH_3-N$ were 24% and 20%, respectively (P<0.05). The average removal rates of $NO_3-N$ and TN were less than 10% (P>0.05). On the other hand, the average removal rates of $PO_4-P$ and TP were more than 65% (P<0.01). Interestingly, the abundance of phytoplankton in the effluent was decreased about 2.6 times compared to that of the influent, whereas the abundance of zooplankton in the effluent was increased about 3.5 times compared to that of the influent. Overall, particulate matters (SS, Chl-a and TP) and dissolved nutrients ($NO_2-N$, $NH_3-N$ and $PO_4-P$) were particularly reduced at high rates. Therefore, application of our constructed floating wetland in a eutrophic lake improved the water quality and demonstrated a potential for algal bloom mitigation.

Characteristics of Coagulation Treatment for Wood Tar Waste Water in a Biomass Gasification Plant (바이오매스 가스화 발전설비의 목질계 타르폐수 응집 처리 특성)

  • Kim, I tae;Ahn, Kwangho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.573-577
    • /
    • 2015
  • There are difficulties in removing wood tar wastewater coming from the power plants that use wood-based fuels due to its intermittent occurrences and severe changes in the amount and concentration. This study investigated the treatment characteristics through physicochemical treatment, an improved method from the existing ones using bag filters and activated carbons to treat wood tar wastewater. In the case of chemical properties of wood tar wastewater, the content of phenols was found to be more than two times higher than that of guaiacols and carbohydrates. Installation is done to ensure that NaOH and PAC are injected automatically according to the change of pH, and then pH, turbidity and SS of the final treated water were examined. The results were 5.9, 12.6 NTU and 15.1 mg/L respectively, which confirmed the possibility of the treated water as circulation water of power plants. In the physical treatment process using a conventional bag filter, removal efficiency of chemicals was about 20%, but the treatment efficiency was improved to show chemical removal efficiency of about 80% through flocculation and sedimentation.

Variation of Natural Organic Matter Characteristics through Water Treatment Processes (정수공정별 천연유기물질의 특성 변화)

  • Hwang, Jeong-Eun;Kang, Lim-Seok;Kim, Seung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1253-1261
    • /
    • 2000
  • Natural organic matter (NOM) which occurs ubiquitously in both surface and ground waters, consists of both humic (i.e., humic and fulvic acids) and nonhumic components. NOM in general as well as certain constituents are problematic in water treatment. From a regulatory perspective, concerns focus upon the role of NOM constituents as disinfection byproduct (DBP) precursors. The fractionation of NOM through water treatment processes can provide insight into treatment process selection and applicability. Problematic NOM fractions can be targeted for removal or transformation. Significant source-related differences in NOM were observed among various source waters. This study found that bulk Dissolved Organic Carbon (DOC) concentration was hardly removed by oxidation process. Oxidation transformed high Molecular Weight (MW) hydrophobic fraction into low MW hydrophilic fraction. Ozone reduced s-pecific Ultraviolet Absorbance (SUVA) value more than chlorine. High MW hydrophobic fraction was effectively removed by coagulation process. About 50% of Trihalomethane Formation Potential (THMFP) was removed by coagulation process.

  • PDF

Derivation of Optimal Conditions and Effect of Treated Water Quality for Treatment of Drinking Water using Inorganic Membrane (무기막을 사용한 먹는물 처리 시 최적의 조건 도출 및 처리수질에 미치는 영향)

  • Won, Chan-Hee
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.543-549
    • /
    • 2018
  • In this study, the treatment efficiency of inorganic membrane according to the flux that blending raw water was investigated at the laboratory level. Based on the results of each blending and flux, we obtained the best efficiency according to each measurement item. The treatment efficiencies were different depending on the raw water and treatment amount of the treated water. Especially, turbidity removal efficiency was high. In the case of $UV_{254}$, the removal efficiency according to the concentration of the raw water and the removal efficiency according to the flux of the treated water showed a maximum of 69 % to minimum of 48 %. In the case of TOC and DOC, the processing efficiency was 22 % and 28 %, respectively, because the organic value of the raw water was low. These results suggest that there is an optimal process to effectively remove contaminants from the inorganic membrane process, and it is necessary to optimize it according to operating conditions.

Study of back surface field for orientation on Crystalline Silicon solar cell (결정방향에 따른 결정질 실리콘 태양전지 후면전계 특성 연구)

  • Kim, Hyunho;Park, Sungeun;Kim, Young Do;Song, Jooyong;Tark, Sung Ju;Park, Hyomin;Kim, Seongtak;Kim, Donghwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.41.2-41.2
    • /
    • 2010
  • 최근 태양전지 제조비용 절감을 위해 초박형 실리콘 태양전지 개발이 활발히 이루어지고 있다. 이에 따라 후면전계(Back Surface Field, BSF) 특성에 대한 관심이 높아지는 추세이다. 이에 본 연구에서는 후면의 결정방향 및 표면구조에 따라 형성되는 후면전계(BSF)의 특성에 대해 알아보고자 하였다. 후면이 절삭손상층 식각(Saw damage etching) 후 (100)면이 드러난 실리콘 기판과 텍스쳐링(Texturing) 후 (111)면이 드러난 실리콘 기판에 후면 전극을 스크린 인쇄 후 Ramp up rate을 달리 하여 소성 공정(RTP system)을 통해 후면전계(BSF)를 형성하여 비교하였다. 후면전계(BSF)의 형상과 특성만을 평가하기 위하여 염산을 이용하여 후면 전극층을 제거하였다. 후면 전극 제거 후 주사전자현미경(Scanning Electron Microscopy)과 3차원 미세형상측정기(Non-contacting optical profiler)로 후면전계(BSF)의 형상을 비교하였다. 또한 후면전계(BSF)의 특성을 평가하고자 Quasi-Steady-State Photo Conductance(QSSPC)를 사용하여 포화전류(Saturation current, $J_0$)을 측정하였고, 면저항 측정기(4-point probe)로 면저항을 측정하여 비교하였다. 후면 전계(BSF)는 (100)면과 (111)면에서 모두 Ramp up rate이 빠를수록 향상된 특성을 보였고, (111)면에서 더 큰 차이를 보였다.

  • PDF