• 제목/요약/키워드: 클립영상

검색결과 56건 처리시간 0.027초

Research on Effects of Three Different Designs and Implementations on Cyber Education (정보활용기술 발전에 따른 효과적 사이버 교육을 위한 설계 및 구현의 차이에 대한 연구)

  • Ha, Tai-Hyun;Kang, Jung-Hwa
    • The Journal of Korean Association of Computer Education
    • /
    • 제6권4호
    • /
    • pp.71-83
    • /
    • 2003
  • This study is aimed to develop and evaluate different approaches for cyber education. The project involved the development of sample cyber education programs using different design approaches, with built-in evaluation mechanisms. The different design approaches depend on what delivery technologies are involved. In the First Generation, the delivery technologies use text, flash and animation, whereas the synchronized content to video and audio are used in the Second and the Third Generations but the difference is the delivery method used by the videoclip. Tests were carried out through self-assessment to measure and analyze the efficient teaching. The results show that the Third generation technologies were the most effective method for cyber education. However, since the Third generation program is developed in multimedia, it tends 10 require higher development costs, and more advanced hardware and software as well as a higher bandwidth for network. Therefore, the research indicates that the development of technical supports, like loading speed, has to be solved simultaneously with the development of multimedia products for effective cyber education.

  • PDF

User-centric Immersible and Interactive Electronic Book based on the Interface of Tabletop Display (테이블탑 디스플레이 기반 사용자 중심의 실감형 상호작용 전자책)

  • Song, Dae-Hyeon;Park, Jae-Wan;Lee, Chil-Woo
    • The Journal of the Korea Contents Association
    • /
    • 제9권6호
    • /
    • pp.117-125
    • /
    • 2009
  • In this paper, we propose user-centric immersible and interactive electronic book based on the interface of tabletop display. Electronic book is usually used for users that want to read the text book with multimedia contents like video, audio, animation and etc. It is based on tabletop display platform then the conventional input device like keyboard and mouse is not essentially needed. Users can interact with the contents based on the gestures defined for the interface of tabletop display using hand finger touches then it gives superior and effective interface for users to use the electronic book interestingly. This interface supports multiple users then it gives more diverse effects on the conventional electronic contents just made for one user. In this paper our method gives new way for the conventional electronics book and it can define the user-centric gestures and help users to interact with the book easily. We expect our method can be utilized for many edutainment contents.

Optimal Channel Power Allocation by Exploiting Packet Semantics for Real-time Wireless Multimedia Communication (실시간 멀티미디어 통신을 위한 의미 기반 채널 파워 할당 기법)

  • Hong, Sung-Woo;Won, You-Jip
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • 제47권1호
    • /
    • pp.171-184
    • /
    • 2010
  • In this work, we develop a novel channel power allocation method for the real-time multimedia over the wireless network environment. Since each frame has different effect on the user perceivable QoS, improving packet loss does not necessarily coincide with perceivable improvements in QoS. A new channel power control scheme is suggested based on the quantified importance of each frame in terms of user perceivable QoS. Dynamic programming formulation is used to obtain optimal transmit power which minimizes power consumption and maximizes user perceivable QoS simultaneously. The experiment is performed by using publicly available video clips. The performance is evaluated using network simulator version 2 (NS 2) and decoding engine is embedded at the client node, and calculated PSNR over the every frame transmitted. Through the semantics aware power allocation (SAPA) scheme, significant improvement on the QoS has been verified, which is the result of unequal protection to more important packets. SAPA scheme reduced the loss of I frame by upto 27% and reduced power consumption by upto 19% without degradation on the user perceivable QoS.

Context-Dependent Video Data Augmentation for Human Instance Segmentation (인물 개체 분할을 위한 맥락-의존적 비디오 데이터 보강)

  • HyunJin Chun;JongHun Lee;InCheol Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • 제12권5호
    • /
    • pp.217-228
    • /
    • 2023
  • Video instance segmentation is an intelligent visual task with high complexity because it not only requires object instance segmentation for each image frame constituting a video, but also requires accurate tracking of instances throughout the frame sequence of the video. In special, human instance segmentation in drama videos has an unique characteristic that requires accurate tracking of several main characters interacting in various places and times. Also, it is also characterized by a kind of the class imbalance problem because there is a significant difference between the frequency of main characters and that of supporting or auxiliary characters in drama videos. In this paper, we introduce a new human instance datatset called MHIS, which is built upon drama videos, Miseang, and then propose a novel video data augmentation method, CDVA, in order to overcome the data imbalance problem between character classes. Different from the previous video data augmentation methods, the proposed CDVA generates more realistic augmented videos by deciding the optimal location within the background clip for a target human instance to be inserted with taking rich spatio-temporal context embedded in videos into account. Therefore, the proposed augmentation method, CDVA, can improve the performance of a deep neural network model for video instance segmentation. Conducting both quantitative and qualitative experiments using the MHIS dataset, we prove the usefulness and effectiveness of the proposed video data augmentation method.

Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques (유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가)

  • Ban, Tae-Joon;Jeon, Soo-Dong;Kwak, Jung-Won;Baek, Geum-Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제24권2호
    • /
    • pp.183-188
    • /
    • 2012
  • Purpose: The concern of improving the quality of life and reducing side effects related to cancer treatment has been a subject of interest in recent years with advances in cancer treatment techniques and increasing survival time. This study is an analysis of differing scattered dose to the contralateral breast using common different treatment techniques. Materials and Methods: Eclipse 10.0 (Varian, USA) based $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FiF (field in field) plan were established using CT image of breast phantom which in our hospital. Each treatment plan were designed to exposure 400 cGy using CL-6EX (VARIAN, USA) and we measured scattered dose at 1 cm, 3 cm, 5 cm, 9 cm away from medial side of the phantom at 1 cm depth using ionization chamber (FC 65G, IBA). We carried out measurement by separating effect of medial tangential field and lateral tangential field and analyze. Results: The evaluation of scattered dose to contralateral breast, $30^{\circ}$ EDW plan, $15^{\circ}$ wedge plan, $30^{\circ}$ wedge plan, Open beam plan, FIF plan showed 6.55%, 4.72%, 2.79%, 2.33%, 1.87% about prescription dose of each treatment plan. The result of scattered dose measurement by separating effect of medial tangential field and lateral tangential field results were 4.94%, 3.33%, 1.55%, 1.17%, 0.77% about prescription dose at medial tangential field and 1.61%, 1.40%, 1.24%, 1.16%, 1.10% at lateral tangential field along with measured distance. Conclusion: In our experiment, FiF treatment technique generates minimum of scattered dose to contralateral breast which come from mainly phantom scatter factor. Whereas $30^{\circ}$ wedge plan generates maximum of scattered doses to contralateral breast and 3.3% of them was scattered from gantry head. The description of treatment planning system showed a loss of precision for a relatively low scatter dose region. Scattered dose out of Treatment radiation field is relatively lower than prescription dose but, in decision of radiation therapy, it cannot be ignored that doses to contralateral breast are related with probability of secondary cancer.

  • PDF

Statistical Analysis of Operating Efficiency and Failures of a Medical Linear Accelerator for Ten Years (선형가속기의 10년간 가동률과 고장률에 관한 통계분석)

  • Ju Sang Gyu;Huh Seung Jae;Han Youngyih;Seo Jeong Min;Kim Won Kyou;Kim Tae Jong;Shin Eun Hyuk;Park Ju Young;Yeo Inhwan J.;Choi David R.;Ahn Yong Chan;Park Won;Lim Do Hoon
    • Radiation Oncology Journal
    • /
    • 제23권3호
    • /
    • pp.186-193
    • /
    • 2005
  • Purpose: To improve the management of a medical linear accelerator, the records of operational failures of a Varian CL2l00C over a ten year period were retrospectively analyzed. Materials and Methods: The failures were classified according to the involved functional subunits, with each class rated Into one of three levels depending on the operational conditions. The relationships between the failure rate and working ratio and between the failure rate and outside temperature were investigated. In addition, the average life time of the main part and the operating efficiency over the last 4 years were analyzed. Results: Among the recorded failures (total 587 failures), the most frequent failure was observed in the parts related with the collimation system, including the monitor chamber, which accounted for $20\%$ of all failures. With regard to the operational conditions, 2nd level of failures, which temporally interrupted treatments, were the most frequent. Third level of failures, which interrupted treatment for more than several hours, were mostly caused by the accelerating subunit. The number of failures was increased with number of treatments and operating time. The average life-times of the Klystron and Thyratron became shorter as the working ratio increased, and were 42 and $83\%$ of the expected values, respectively. The operating efficiency was maintained at $95\%$ or higher, but this value slightly decreased. There was no significant correlation between the number of failures and the outside temperature. Conclusion: The maintenance of detailed equipment problems and failures records over a long period of time can provide good knowledge of equipment function as well as the capability of predicting future failure. Wore rigorous equipment maintenance Is required for old medical linear accelerators for the advanced avoidance of serious failure and to improve the qualify of patient treatment.