• Title/Summary/Keyword: 크로스실린더

Search Result 13, Processing Time 0.019 seconds

Expectation of Astigmatism by Spherical Equivalent Visual Acuity (등가구면 시력으로부터 난시량의 예측)

  • Kim, Sang-Yoeb;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.167-170
    • /
    • 2011
  • Purpose: This study was tried whether expectation of astigmatism from spherical equivalent visual acuity was possible. Methods: For 54 men and women (108 eyes) corrected to emmetropia, average age of 23.3, changes of visual acuity (5m) were measured with an increasing the powers at every ${\pm}$0.25D when the (-) axis of cross cylinder is $180^{\circ}$, $90^{\circ}$, and $45^{\circ}$, respectively. Results: As the power of cross cylinder was increased, visual acuity was decreased. When the powers of cross cylinder were ${\pm}$2.50D ($180^{\circ}$ and $90^{\circ}$) and ${\pm}$2.25D ($45^{\circ}$), visual acuity was 0.05 which is the minimum measurement possible. Conclusions: The diagram on astigmatism dealing with each spherical equivalent visual acuity was able to tabulate.

Changes of Corrective Astigmatism Values Depending on Position of Circle of Least Confusion in Astigmatic Refining Test Using Cross Cylinder (크로스실린더를 이용한 난시정밀검사에서 검사 전 최소착란원 위치에 따른 난시교정값의 변화)

  • Kim, Sang-Yeob;Lee, Min Jae;Lee, Kang Cheon;Lee, Tae Hui;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.349-354
    • /
    • 2015
  • Purpose: To investigate the changes of corrective values of astigmatism caused by the position of circle of least confusion on retina in refining astigmatic test using cross cylinder. Methods: 62 subjects (115 eyes) aged $22.24{\pm}2.48$ years participated for this study. After astigmatic test using a radial chart, refining test was performed using a cross cylinder in a condition of maximum plus to maximum visual acuity (MPMVA). Astigmatic refining test was repeatedly performed in each condition of which S+0.75 D, S+0.50 D, S+0.25 D, S-0.25 D, S-0.50 D, and S-0.75 D are added to spherical lenses of MPMVA. The measured values were compared with the values in MPMVA condition. Results: As compared with values in condition of MPMVA, change of astigmatic axis was increased with add the power of (+) spherical lenses and (-) spherical lenses. In same spherical condition, change of astigmatic axis was decreased with increment of astigmatic power (p<0.05). The corrective power of astigmatism was reduced with increment of (+) spherical lenses (p<0.05), and was raised with increment of (-) spherical lenses compared with the power in MPMVA condition. In case of adding (+) spherical lenses, difference of astigmatic power increased with increment of corrective astigmatism power in same test condition. Conclusions: In order to obtain a proper values for corrective astigmatism, position of circle of least confusion should be accurately adjusted before the performing an astigmatism's refining test.

Repeatability of Monocular Spherical Endpoints Test (단안 구면 끝점검사의 반복성 검증)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.209-213
    • /
    • 2012
  • Purpose: To assess the repeatability of the monocular spherical endpoints, a test was performed with four methods which are the retinoscopy, the MPMVA (maximum plus maximum visual acuity) method, the R/G duochrome method, and the crossed cylinder method. Methods: The monocular spherical endpoints was measured by four kinds of method (Retinoscopy, MPMVA method, R/G duochrome method, Crossed cylinder method) on 20 subjects (40 eyes) of average age 23.0 year-old men and women. After a week, retest was performed by same procedure and the test-retest repeatability was assessed by using the Bland-Altman plot analysis. Results: The test-retest mean difference of retinoscopy was the smallest diopters of -0.03 and that of R/G duochrome method was the largest diopters of -0.19. The upper/lower 95% limits of agreement for repeatability was the narrowest in retinoscopy and was the widest in crossed cylinder method. When compared the spherical endpoints of each eye between by retinoscopy and by other three methods, the error rate of ${\pm}0.25D$ in total eyes was 85% in MPMVA method, 80% in R/G duochrome method, and 24% in crossed cylinder method. Conclusions: Test-retest repeatability is the highest in the retinoscopy, and the retinoscopy, the MPMVA method, and R/G duochrome method are suitable for monocular spherical endpoints test.

Presbyopic Addition of Using Method of Cross Cylinder (크로스실린더 검사법을 이용한 노안의 근용 가입도)

  • Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.71-75
    • /
    • 2007
  • This research was conducted from 1 March 2005 to 28 February 2007. We collected data from optician stores around Kwang-Ju city, 208 people aged 40 to 80 years using the cross cylinder method to find out age and gender dependence of near addition. 1. Age dependence of Refractive error shows 5% of emmetropia 34% of myopia and 43% of hyperopia. These results reveal that rate of hyperopia is higher than emmetropia and myopia. Mixed Astigmatism rate was 18%. 2. Near addition required to correct Presbyopia is analyzed as functions of gender and ages. In case of man: 40-44 (+0.75D), 45-49(+1.25D), 50-54(+1.41D), 55-59(+1.92D), 60-64(+2.35D), 65-69(+1.97D), 70(+3.12D), In case of woman: 40-44 (+1.08D), 45-49 (+1.38D), 50-54 (+1.67D), 55-59(+2.05D), 60-64 (+2.50D), 65-69 (+2.57D), $70{\leq}(+3.18D)$. Result shows it's Adding power higher than man. 3. Age dependence of Axis of Astigmatism. In case of horizontal astigmatism 61.2%, vertical 2.8% and rest else for 36%. Setting point from Binocular vision tells that average adding power of 40-44 (+0.75D) or (+1.00D), 45-49 (+1.25D) or (+1.50D), 50-54 (+1.50D), 55-59 (+2.00D), 60-64 (+2.50D), 65-69 (+2.50D) or (+2.75D), over $70{\leq}(+3.00D)$ or (+3.25D) of average adding power.

  • PDF

Face Texture Generation using an Image Alignment Algorithm based on Variable-Sized Blocks of Cylindrical Prototype Model (실린더형 원형모델의 가변적 블록크기를 기반으로 하는 영상정렬 알고리즘을 이용한 얼굴 텍스쳐 생성)

  • Lee, Joong-Jae;Choi, Hyung-Il
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.11
    • /
    • pp.855-863
    • /
    • 2001
  • We propose an image alignment algorithm based on variable-sized blocks of cylindrical prototype model to generate a face texture for a realistic 3D face model. This is a block matching algorithm which aligns 2D images of a 3D cylindrical model using th correlation between them. While matching blocks, it does not use same sized blocks with considering a curvature of 3D model. And we make a texture of aligned images using a technique of image mosaic. For this purpose, we stitch them with assigning linear weights according to the overlapped region and using the cross-dissolve technique.

  • PDF

A Clinical Study on Presbyopia in Wearing the Near Spectacle for the First Time (근용 안경을 최초 장용하는 노안에 대한 임상적 연구)

  • Yoo, Jong-Sook;Lim, Hyeon-Seon;Lee, Soo-Cheon;Hwang, Jung-Hee;Kim, Hyo-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.103-107
    • /
    • 2008
  • Purpose: This research measured the near addition powers of presbyopia in wearing the near spectacle for the first time. Methods: We evaluated age, sex, working group, spherical power and cylindrical power and measured the power of refractive error performed the both eyes (310 eyes) of 155 subjects subjectively noncycloplegic and power of addition using the cross cylinder method. Results: There were measured the near addition powers in the range of +0.75D ~ +1.75D. In case of the average addition, they were measured with +1.06D in subjects under 43 years of age, +1.08D in 44 to 46 years, +1.23D in 47 to 49 years and +1.46D in over 50 years of age. The average age in subjects was 47.6 years old and 74 male, 81 female, 71 near sighted working group and 83 far sighted working group. Conclusions: Near addition was correlated with age, working group and cylindrical power (P<0.05, P<0.05, P<0.05).

  • PDF

The Study of Accommodation Assessment in Binocular Functional Test (양안시검사의 조절평가 연구)

  • Cho, Young-Rae;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.61-67
    • /
    • 2007
  • The binocular functional test was performed in test of both accommodation and convergence. The balance of accommodation and convergence was important. Objects were 100 adults in 18-36 years old ages. The used apparatus was vision tester(Shinnippon VT10)and visual chart(Shinnippon CT30). Accommodative lag test by fused cross cylinder were that in case of high 39.0%, in case of low 14.0%. Negative relative accommodation were that in case of high 23.0%, in case of low 38.0%. Positive relative accommodation were that in case of high 29.0%, in case of low 23.0%. In 18% were case of low accommodation.

  • PDF

Face Texture Generation using Geometric Characteristics of Ellipsoid Prototype Model (타원체형 모텔의 기하학적인 특성을 이용한 얼굴 텍스쳐 생성)

  • 노명우;이중재;김계영;최형일
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.346-348
    • /
    • 2003
  • 본 논문에서는 얼굴 형태와 유사한 타원체형 모텔의 가변적 블록크기를 기반으로 하는 영상정렬 알고리즘을 제안한다. 실린더형 모델을 사용한 기존의 방법은 블록정합 수행 시 좌우 곡률을 고려하므로 좌우영상은 정확히 정렬하지만 상하 부분은 사람의 두상모양이나 턱 구조와 다르기 때문에 상하 영상을 정렬할 때 오류가 발생한다. 본 논문에서 제안하는 알고리즘은 얼굴 모델의 상하좌우의 곡률에 따라 가변적인 블록크기론 사용하고 영상의 상관관계를 이용하여 정확한 정렬을 할 수 있도록 한다. 그리고 얼굴 텍스쳐영상을 생성하기 위하여 영상 모자익 기법을 사용하며 영상들이 서로 잘 융합하도록 크로스디졸브(Cross dissolve) 기법을 적용하여 영상을 스티칭한다.

  • PDF

Characteristics of Accommodative Lags Determined by Objective and Subjective Methods and Their Correlation (타각적 및 자각적으로 결정된 조절래그의 특성과 상관관계)

  • Yu, Dong-Sik;Kwak, Ho-Weon;Roh, Byeong-Ho;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.333-339
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate clinical characteristics of subjective accommodative lags determined by fused cross-cylinder (subjective method), and an open-field autorefractor (objective method) under uncorrected and corrected conditions. Methods: Thirty three healthy subjects (26 males and 7 females aged $23.73{\pm}1.35$ years from 22 to 27 years) participated. Four methods were used to determine accommodative lag: (1) a subjective method with the fused cross-cylinder (FCC) under +2.00 D fogging lenses condition, (2) an objective method with the autorefractor under uncorrected condition (3) a corrected method (effective accommodative lag) using equations presented by Gwiazda et al. in objective methods, and (4) a corrected method using equations presented by Mutti et al. in objective methods. Results: The mean accommodative lags were 0.72 D for subjective method, 0.82 D for uncorrected objective method, 0.88 D for corrected method with Gwiazda's equations, and 0.78 D for corrected method with Mutti's equations. There were significant differences between the objective accommodative lags, but no significant differences between the objective and subjective accommodative lags. The effective accommodative lags showed significant correlations between phorias and refractive errors. The effective accommodative lag by Mutti's equations had a high correlation with uncorrected accommodative lags (r=0.99, p<0.001). Conclusions: The objective accommodative lag correlated with phorias and refractive errors. Especially, The effective accommodative lag using Mutti's equations may be considered for clinical availability and qualitative evaluation associated with symptoms.

The Accommodative Lag and Refractive Error in Early Adults (초년 성인의 굴절이상과 조절래그 분포의 연관성)

  • Baarg, Saang-Bai;Jeong, Youn Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.59-65
    • /
    • 2012
  • Purpose: The purpose of this study was to determine the distribution and correlation of accommodative lag with refractive error. Method: We had tested the clinical refraction and the accommodative lag in clinically normal 49 young adults (total 98 eyes) aged 18 to 25 years without abnormal binocular function. Monocular and binocular accommodative lag were tested with 0.50 D cross-cylinder lens and near vision test chart which had cross-hairs after full correction of LogMAR visual acuity over 0.05. Results: There was no statistical differences in monocular accommodative lag between right ($0.64{\pm}0.64$ D) and left eye ($0.63{\pm}0.64$)(p=0.858). The accommodative lag of male was higher than female and the range of the value was broader than female in binocular accommodative lag (p=0.015). The wider the inter-pupillary distance was, the higher the accommodative lag was (p=0.003). However, there were no differences with age (p=0.800) and dominant eye (p=0.402). The ranges of accommodative lag of low, middle, and high myopia were 0.75 ~ -0.25 D, 1.25 ~ -0.50 D, and 1.50 ~ -0.75 D, respectively, and the regression was 'y = -0.03953x+0.09205'. Conclusions: These data suggest that clinically normal young adults with high amounts of refractive error have more variable accommodative lag and increased spherical equivalent refraction.