• Title/Summary/Keyword: 쿨링센터

Search Result 4, Processing Time 0.018 seconds

A Study on the Cooling Center Manual of Facility and Maintenance for Extreme Heat Disaster (폭염재난에 대응하는 Cooling Center 시설 및 운영기준에 관한 연구)

  • Kim, Jin-Wook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.17-22
    • /
    • 2008
  • Including heat wave, Climate change caused 150,000 casualty in 2000 and heat waves are meteorological events that pose a serious threat to human health. A heat wave is defined as "a period of abnormally and uncomfortably hot and usually humid weather". There is a need for the prevention of health effects due to weather and climate extremes. This study intends to propose the necessity of Response System to correspond to extreme heat. And this research focused on Cooling Center manual of facility and maintenance for extreme heat disaster. It would be useful to be planned based on community and to be taken a role as an E.O.C.(Emergency Operating Center). As a conclusion elderly watching system and the requirements regional cooling center facility was proposed.

A Study on Foreign Cases for the Management of Extreme Heat Response Plan in Korea (우리나라 폭염종합대책의 효율적 운영에 관한 외국사례 연구)

  • Kim, Ji-Young;Kim, Jung-Ok;Yu, Ki-Yun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.2 s.25
    • /
    • pp.25-33
    • /
    • 2007
  • In most developed countries, Extreme heat alter system operates every summer and the response plan to be issued according to this system is composed of some government agencies sub-plans. The National Emergency Management Agency in Korea develops response plan but it is not composed of the definition of the heat vulnerability and the concrete agency roles. Therefore, this study analyses foreign cases in three processing: preparedness, response, recovery and reviews the status of heat response plan. As a conclusion, the study suggests two ways of Extreme heat management into Korean heat response plan such as strengthening its institutional position and complementing its context.

Analysis and Improvement of Cooling System for Energy Saving in Data Center Building (데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안)

  • Jung, Yong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

Energy Saving Effect of CCHP System Using High Temperature Polymer Electrolyte Fuel Cell for Data Centers (고온 고분자 연료전지를 이용한 데이터 센터용 CCHP 시스템의 에너지 절감 효과)

  • SEONGHYEON HAM;TAESEONG KANG;WON-YONG LEE;MINJIN KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.187-195
    • /
    • 2023
  • Data centers not only consume significant electricity to operate IT equipment, but also use a lot of electricity to cool the heat generated by IT equipment. The waste heat of a high-temperature polymer electrolyte fuel cell (HT-PEFC) is capable of producing cooling , so it can be effectively applied to data centers that require cooling throughout the year. The energy-saving effects of the proposed combined cooling, heat and power (CCHP) system using HT-PEFC. That was analyzed based on the annual energy consumption data of a specific data center. When the system was running at 100% of the year, It was shown that the installation of 1 MW of the proposed system can save 3,407 MWh of electrical energy per year. In addition, compared to the existing system, the annual power usage effectiveness can be improved from 2.0 to 1.57 and 6,293 MWh of extra heat energy per year can be produced to sell. Furthermore, sensitivity analysis was performed on the fuel cell operating temperature and current density to guide the appropriate installation capacity of the proposed system.