• Title/Summary/Keyword: 쾌적지수

Search Result 60, Processing Time 0.027 seconds

The Spatial Variations in Sex Age Structure in the Kyonggi Province (경기지역의 성별 연령구조지수에 관한 공간적 연구)

  • Kwon, Yong-Woo
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.1
    • /
    • pp.35-50
    • /
    • 1997
  • The purpose of this research seeks to analyze the spatial variations in the sex age structure which have been shown to exist within the study atrea, the Kyonggi province in Korea. In this study it is desired to use the Age Structure Index developed by Coulson in order to describe thi sex age structure of each of 186 tracts that comprise the tracted portion of the Kyonggi province. The mechanics of computing the Age Structure Index are found in the equation describing a linear least squares trend line: y=a+bx. For each census tract, the percentage of the population in each age group(y) was plotted against the middle age of each age group(x). The a is a constant representing the value of y, when x equals zero. The b is the regression coefficient and is a measure of the angle of the slope of the least squares trend line. Thus the value of b is the Age Structure Index for each census tract. The major results of this investigation can be summarized as follows: The spatial distributions of sex age structures in the Kyonggi province are far from random. They have exhibited great regularity with the yonger sex age structures near Seoul and a sharp decline to the older sex age structures out in all derections towards rural region. The results of this investigation should have important general significance for the study of the Kyonggi province Age Structure Index is a flexible, operational definition shich allows sex age structure to be measured, mapped, and incorporated in a wide variety of methods of statistical analysis. Futurer, it has been demonstrated that sex age structure varies spatially within Seoul metropolitan finge and that this variation is relagfed to many other attributes of the population. Especially, Age Structure Index is strongly related to the variables-rate of population growth rate. density, rate of numbers of manufacturing, land price. At the same time, considerably more research is needed before a genmeral body of knowlege concerning sex age structure can be developed.

  • PDF

The Effect of The Index of Indoor Environment on The Productivity (실내환경지수가 생산성에 미치는 영향)

  • Kim, Myung-Ho;Lee, Ye-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.615-621
    • /
    • 2018
  • To enhance the energy saving and comfort of indoors, this study performed a stimulation of sound fluctuation, color temperature, and aroma. The experiment with EEG, HRV, and Vibra images was conducted in an environmental test room with a temperature of $25[^{\circ}C]$, relative humidity of 50[RH%], air current speed of 0.002[m/s], and illuminance of 1000[lux]. The stimulation experiment set up different sensory stimulation conditions, such as before exposure, single-sensory stimulation of fluctuation a=1.106 jazz music, single-sensory stimulation of RED color lighting, single-sensory stimulation of scent aroma, and multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma. After the multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting and scent aroma, the capacity for work and attention were increased, and the stress index and fatigue degree were decreased. In addition, multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma were effective in maintaining a stable heart and health. In addition, the Vibra image appeared to decrease tension/anxiety and stress. The multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma help increase the Neuro-energy more than that by no exposure and single-sensory stimulation.

Development of Thermal Comfort Evaluation Map by the Land Cover in Yeongnam Region (영남지역의 토지피복에 따른 열쾌적성평가도 구축)

  • Kang, Dong-Hyun;Choi, Chul-Hyun;Jung, Sung-Gwan
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.2
    • /
    • pp.136-155
    • /
    • 2014
  • The purpose of this study is to analyze the thermal comfort in Yeongnam area using climatic data and GIS data in order to determine regions necessary to improve thermal environment policies. The results of the calculated PET show that Daegu city is high and Bonghwa-gun is low compared to other regions. PET was compared with the typical classification according to regional characteristics. As a result, PET value of rural areas such as Changnyeong-gun, Haman-gun and Goryeong-gun was high but Green space was too low compared to other rural areas. Yeongnam area was classified according to the value of PET using cluster analysis. As a result, more low grade areas show that green space ratio was low and facility area was high. It is determined that there is a relationship between thermal comfort and land cover. The thermal comfort evaluation map in Yeongnam area will be useful for urban planning in order to establish a sustainable city in climate change.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

A Study on the Indoor Temperature effects on Neuro-energy (실내 온도가 뉴로에너지에 미치는 영향에 관한 연구)

  • Kim, Jung-Min;Kim, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2436-2442
    • /
    • 2014
  • In this study, EEG, HRV, and Vibra image were compared and analyzed in the environmental test room due to variation of temperature. The condition of the environmental test room was in relative humidity 50[RH%], air current speed 0.02[m/s] and illuminance 1000[lux] with setting up different temperatures from $18[^{\circ}C]$ to $31[^{\circ}C]$. At temperature $25[^{\circ}C]$, relative $M{\alpha}$ wave, relative $M{\beta}$ wave, $\frac{SMR}{\theta}$, and SDNN were revitalized, and both sides ${\alpha}$ wave asymmetry index $A_2$, HRT, stress index, and fatigue degree were decreased. Therefore, it was found that temperature $25[^{\circ}C]$ effects to increase the Neuro-energy like amenity, productivity, and concentration.

Algorithm for Air Conditioning Service Based on IR-UWB Sensor (IR-UWB 센서 기반의 에어컨 서비스 알고리즘)

  • Kim, Jong-Min;Kang, Tae-Hyung;Ryu, Gab-Sang
    • Journal of Internet of Things and Convergence
    • /
    • v.7 no.4
    • /
    • pp.1-7
    • /
    • 2021
  • Recently, technological differentiation(sensor, AI) of products using IoT technology to satisfy consumer needs in the mature market for smart home appliances has received a lot of positive responses. However, air conditioner products are in the early stages of convergence technology. Therefore, air conditioner products are fields that require ICT technologies for information production, collection, processing, storage, and service development beyond IoT. In this paper, we collect and store contactless bio-signal using IR-UWB radar technology. The blowing direction of the air conditioning is controlled according to bio-signal and user's sleep is monitored to provide an optimal sleep environment. In addition, we propose a service algorithm that can provide comfort with changes in the optimal conditions of air conditioning and emotional lighting depending on the discomfort index environment. Through this study, we developed an intelligent smart air conditioning service platform with ICT technology of bio-signal, discomfort index, and emotional lighting.

Analysis of Physical Characteristics of Sound Environment and the Subjective Reactions in Hanok Complexes (한옥주거단지 소리환경의 물리적 특성과 주관반응의 관계 분석)

  • Shin, Yong-Gyu;Park, Hyeon-Ku;Kook, Chan;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.2
    • /
    • pp.154-161
    • /
    • 2014
  • Demands for Korean Traditional Residence Complexes as a more humane resident space have recently been increasing for the purposes of users' health and convenience, built with the purpose of reflecting various trends. This study is aimed at examining the physical characteristics of design in residence complexes by analyzing the physical characteristics of the sound environment as auditory elements of Hanok Complexes and the relationship between spatial and visual test values. The results were shown as follows: In subjective evaluation at Hanok, Natural sounds were recognized higher but artificial sounds were lower. According to the interrelationship analysis between subjective evaluation and physical measurement values, entrance (regular-StdDev), yard (regular-NbEm, friendly-G), waterside (regular-articulation index(rooms), StdDev, $L_{min}$, Rem), etc had been shown highly related.

Evaluation of Aquatic Habitat Suitability (하천 수생 서식환경의 적합성 평가)

  • Kim, Kyu-Ho;Im, Dong-Kyun;Jung, Sang-Hwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1149-1153
    • /
    • 2007
  • 하천 개발 사업, 하천 취수량의 증가, 각종 오염원의 유입으로 하천수질 악화, 그리고 하천 구조 개선 등에 따른 수량과 수질, 서식 구조 측면에서 하천 생태계의 위협과 파괴가 이루어지고 있다. 최근에 보다 쾌적하고 자연에 가까운 하천 생태계의 서식 공간을 보전하고자 하는 노력이 증대하고 있다. 이 경우, 하천생태계 보전을 위해 무엇보다 중요한 것은 적정한 흐름 영역을 확보하여 생명이 살아 숨쉬는 하천상을 유지할 수 있어야 한다. 따라서 물 이용측면과 하천 수생 서식처 유지측면의 갈등을 해결할 수 있는 최적화된 유량설정 기법이 필요하다. 본 연구에서는 어류 서식환경을 평가하기 위해 가장 광범위하게 이용되고 있고 생태적 특성을 반영할 수 있는 점증 유량 방법론(IFIM: Instream Flow Incremental Methodology)의 물리적 서식처 모의 시스템(PHABSIM: Physical Habitat Simulation System)을 적용한다. 미시 서식 조건은 실측한 물리 자료를 이용하여 1차원 수리해석 프로그램을 적용하도록 한다. 대상 구간에 적합한 목표종을 설정하여 목표종에 적합한 서식처 적합도 지수를 산정한 후 물리 서식처 모의 시스템((PHABSIM: Physical HABitat SIMulation system)을 곡릉천 보(洑)구간에 적용하였다. 보로 인하여 주변의 물리서식처가 악화되어 있는 것을 확인할 수 있었다. 본 연구결과는 보에 의한 물리서식처의 영향을 분석함으로써, 보 철거 사업과 같은 하천환경 개선사업의 필요성을 제시하는 기본 자료로 활용될 수 있을 것으로 판단된다.

  • PDF

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Temporal Changes in the Physiological and Psychological Relaxation Effects of a Forest Environment during the Summer (시간 변화에 따른 여름철 산림환경의 생리ᐧ심리적 안정 효과)

  • Injoon Song;Juhyeon Kim;Choyun Kim;Dawou Joung;Yunjeong Yi;Bum-Jin Park;Chorong Song
    • Journal of Korean Society of Forest Science
    • /
    • v.113 no.1
    • /
    • pp.107-117
    • /
    • 2024
  • This study investigated temporal changes in forest physical variables and their effects on thermal comfort and physiological and psychological responses. Environmental factors (air temperature, mean radiant temperature, wind speed, and relative humidity), the predicted mean vote (PMV), and the predicted percentage of dissatisfied (PPD) visitors were continuously measured between 9:00 AM and 6:00 PM. We assessed the physiological and psychological responses (heart rate variability, heart rate, oral temperature, blood pressure, pulse rate, thermal sensation vote, comfort sensation vote, and subjective feelings) of 30 male university students (average age: 21.7±1.9 years), who closed their eyes and relaxed for 5 minutes every hour. Examination of correlations between environmental factors and physiological responses showed that ① the mean radiant temperature, wind speed, and relative humidity significantly changed with time; ② PMV and PPD also showed significant changes over time, and the thermal sensation vote corresponded with PMV; however, the comfort sensation vote did not correspond with PPD; ③ Among the physiological responses, parasympathetic nerve activity, sympathetic nerve activity, heart rate, and diastolic blood pressure significantly varied with time, with parasympathetic nerve activity having the lowest value and sympathetic nerve activity the highest at the highest air temperature (2:00-4:00 PM); and ④ Air temperature, mean radiant temperature, and wind speed showed a negative correlation with parasympathetic nerve activity and a positive correlation with sympathetic nerve activity. These findings indicate that the relaxation effects of the forest environment depend on what time of day people are exposed to it, and the changes occurring in forest environmental factors over time modulate these effects.