• Title/Summary/Keyword: 쾌적도

Search Result 1,755, Processing Time 0.026 seconds

A Study of Walkway Level of service reckon with Pedestrian Characteristic on Complex-transit center (복합환승센터 인근 보행자도로의 시간대별 보행특성을 고려한 서비스수준에 관한 연구)

  • Lee, Gwang-Seon;Choe, Byeong-Mu;Geum, Gi-Jeong
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.5
    • /
    • pp.7-15
    • /
    • 2010
  • The walkway level of service (LOS) is conceptualized using pedestrian flow rate, speed, and density according to the Korean Highway Capacity Manual (KHCM). However, as it is based on the data of commuters at peak hours, it needs to be reevaluated considering various trip purposes and a pleasant pedestrian environment. Thus, the authors aimed to investigate and analyze the characteristics of each group: pedestrians during the peak hour and those during the non-peak hour. Then they were verified statistically for the walkway evaluation criteria. In this study, the authors investigated pedestrian speed and flow in a complex transit center walkway with diverse trip purposes by peak and non-peak hour. Then the authors statistically verified the differences between the groups. A model was built for estimating pedestrian density by speed and flow; it was used to calculate the walkway capacity (67.3p/m/m) corresponding to LOS E. The authors established new criteria for LOS, applying the LOS from the HCM. These standards can then be used as the design standards for pedestrian walkways.

A Study on the Neuro-fuzzy for the setup of convenient bathroom environment. (뉴로-퍼지를 통한 스마트 욕실 환경 구축 연구)

  • Kim, YuJeong;Kim, Hyun;Oh, SooKyeong;Youn, Yeumin;Choi, SeoYoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.299-302
    • /
    • 2019
  • 스마트홈 구축을 위한 다양한 IoT 기술 발전과 더불어 IoT 장비들의 저전력, 고효율, 편리성에 대한 사용자 니즈에 대한 관심이 급증하고 있다. 이러한 사용자 니즈를 반영하듯이 최근 아두이노 및 라즈베리 파이등 저비용으로 IoT 장비를 구축할 수 있는 다양한 연구들이 진행되고 있다. 우리는 본 연구를 통해 뉴로-퍼지기술을 이용해 저전력, 고효율, 편리성을 겸비한 저렴한 IoT 장비 및 솔루션을 제안하고자 한다. 뉴로-퍼지를 이용하게 되면 기존의 단순한 센싱에 대한 제어와 다르게 다양한 환경변수를 분석하고 고려해 효율적인 제어가 가능할 수 있다. 본 논문에서는 욕실 환경에서의 발생할 수 있는 다양한 환경변수를 추출하고 사용자가 편리하게 사용할 수 있도록 실시간 발생하는 상황과 온도, 습도 등을 뉴로-퍼지를 통해 제어할 수 있는 알고리즘을 설계한다. 그리하여 뉴로-퍼지를 이용하여 설계된 욕실환경 제어 시스템은 사용자의 욕실 이용에 효과적인 영향을 줄 수 있을 것이다. 우리는 본 연구에서 저비용 고효율의 효율적 시스템을 구성할 수 있는 IoT 센서와 아두이노 및 라즈베리 파이를 활용해 다양한 IoT 장비들을 모니터링하고 분석하여 쾌적한 스마트 홈을 구축할 수 있는 방향을 제시하였다. 또한 그러한 IoT 장비들을 제어할 수 있는 IoT gateway system을 설계하고 구현하였다.

A study on the Residential Satisfaction of Environmental Condition for Housing Complexes located in Coastal Areas (연안역에 입지하는 주거단지 생활자의 거주환경 만족도에 관한 연구)

  • Lee, Myung-Kwon
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.505-513
    • /
    • 2008
  • Regarding the developmental plans for the coastal areas and marine architectures, this study deal with the overall planning of apartment complexes in waterfront areas, focusing upon the analysis of their comfort and convenience factors from the perspective of the potential residence. It also analysis the intra-complex comfort and satisfaction conditions in terms of their floor-by-floor, directional. and location factors. The results of the study are as follows: 1) The order of respondents' preference on directional factor has been found to be: South > Southeast > Southwest > East > others. 2) 67% of the people surveyed on scenery responded that outward view is considered more significant than the directional factor. 3) A comprehensive analysis of floor zone-specific view preference shared that there were only minor differences among quay wall, arc, and river-seashore types. The impact of the characteristics of the marine environments turned out to be a greater point of consideration; showing that the other of floor-preference is: high-level > ultra-high level > middle level > low level.

A Basic Study on the District Cooling System of LNG Cold Thermal Energy (LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.36-43
    • /
    • 2003
  • This paper provides the possibility of the district cooling system by using a LNG cold thermal energy. A liquefied natural gas provides a plenty of cooling source energy during a gasification of a liquefied natural gas. In recent, an ice thermal storage system is used for cooling a building, and a deep water source cooling system has been introduced as a district cooling system in which is used to cool the office towers and other large buildings in old and new downtown. LNG cooling energy refers to the reuse of a large body of naturally cold fluids as a heat sink for process and comfort space cooling as an alternative of conventional, refrigerant based cooling systems. Coincident with significant clean energy and operating cost savings, LNG cold energy cooling system offers radical reductions in air-borne pollutants and the release of environmentally harmful refrigerants in comparison to the conventional air-conditioning system. This study provides useful information on the basic design concepts, environmental considerations and performance related to the application of LNG cold thermal energy.

  • PDF

Analysis for Characteristics of Driver's Legibility Performance Using Portable Variable Message Sign (PVMS) (운전자 인적요인을 고려한 PVMS 메시지 판독특성 분석)

  • Song, Tai-Jin;Oh, Cheol;Kim, Tae-Hyung;Yeon, Ji-Yoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.4
    • /
    • pp.25-35
    • /
    • 2008
  • Variable Message Sign(VMS) is one of the subsystem of Intelligent Transportation Systems (ITS), which is useful for providing real-time information on weather, traffic and highway conditions. However, there are various situations such as incidents/accidents, constructions, special events, etc., which would be occurred on segments, it is unable to control traffic with only the VMS. Thus, it is essential to use of PVMS(Portable Variable Message Signs), which can move to the location needed traffic control and provide more active traffic information than VMS. This study developed a legibility distance model for PVMS messages using in-vehicle Differential Global Positioning Data(DGPS). Traffic conditions, drivers' characteristics, weather conditions and characteristics of PVMS message were investigated for establishing the legibility model based on multiple linear regression analysis. The factors such as height of PVMS characters, spot speed, age, gender and day and night were identified as dominants affecting the variation of legibility distances. It is expected that the proposed model would play a significant role in designing PVMS messages for providing more effective real-time traffic information.

  • PDF

A Case Study on the Characteristics of Cultural Expression in Contemporary Commercial Architecture Design in China (중국 현대 상업건축 실내 공간의 문화적 표현특성에 대한 사례연구)

  • Yu, DeSheng
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.32-44
    • /
    • 2019
  • Based on the characteristics of cultural expressions, this paper compares and analyzes the cases of representative commercial architectural spaces of six largest cities in China.In order to promoting the sustainable development of the indoor space culture of modern commercial buildings in China.Six cases were analyzed from the viewpoints of cultural tradition, locality, popularity, technology, and ecology. The results are as follows. First, the tradition of culture requires the emphasis on the traditional elements of specific areas in the interior space of commercial architecture.Second, the regional character of culture is closely related to the social and natural environment factors such as the economic development of the interior space of commercial architecture, historical intrinsic space, geographical environmental conditions, and climate.Fourth, the technicality of culture is to integrate construction method, structure form, and material with local culture into commercial architecture interior space.Fifth, cultural ecology places attention to placing plants in the interior space of commercial architecture and creating a healthy, pleasant and safe environment.

Smart Home Service System Considering Indoor and Outdoor Environment and User Behavior (실내외 환경과 사용자의 행동을 고려한 스마트 홈 서비스 시스템)

  • Kim, Jae-Jung;Kim, Chang-Bok
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.473-480
    • /
    • 2019
  • The smart home is a technology that can monitor and control by connecting everything to a communication network in various fields such as home appliances, energy consumers, and security devices. The Smart home is developing not only automatic control but also learning situation and user's taste and providing the result accordingly. This paper proposes a model that can provide a comfortable indoor environment control service for the user's characteristics by detecting the user's behavior as well as the automatic remote control service. The whole system consists of ESP 8266 with sensor and Wi-Fi, Firebase as a real-time database, and a smartphone application. This model is divided into functions such as learning mode when the home appliance is operated, learning control through learning results, and automatic ventilation using indoor and outdoor sensor values. The study used moving averages for temperature and humidity in the control of home appliances such as air conditioners, humidifiers and air purifiers. This system can provide higher quality service by analyzing and predicting user's characteristics through various machine learning and deep learning.

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Cheong, Seong-Ir;Sheng, Nai-Li;Kim, Doo-Hyun;Lee, Jae-Keun;Hwang, Yu-Jin;Park, Jong-Hoon;Seo, Seok-Jang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.402-408
    • /
    • 2009
  • In this paper, the effects of ventilation and humidification on thermal comfort and indoor air quality(IAQ) were evaluated in a classroom when a heat pump system was operated in winter. Thermal comfort parameters, such as temperature, relative humidity, globe temperature and air velocity, were measured at 9 points in the classroom. The concentration of $CO_2$ and total suspended particles(TSP) in the classroom were measured in order to analyze IAQ. Temperature distribution in the classroom was decreased by $2{\sim}5^{\circ}C$ when the ventilation system and the humidifier were operated. When the relative humidity was adjusted to 60% by operating the humidifier and the ventilation system, the predicted mean vote(PMV) in the classroom was within the comfortable range of $-0.5{\sim}0.5$. When the ventilation system was operated, the average concentration of $CO_2$ and TSP were decreased by 645 ppm and 0.17 $mg/m^3$, respectively. This paper suggests the humidification and ventilation conditions to maintain the comfortable environment in the school classroom in winter experimentally.

Analysis of Indoor Air & thermal environment with Hybrid Ventilation system during summer (하계 공동주택 하이브리드 환기시스템 적용에 따른 실내공기 및 열 환경 평가)

  • Kim, Sang-Jin;Kim, Eun-Soo;Kim, Tae-Yeon;Leigh, Seung-Bok
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.387-392
    • /
    • 2006
  • The recent on indoor air problem has led to many studies on the methods and effects of ventilation for better indoor air quality. Although natural ventilation is the most effective and energy-saving method in residental housings, the small size of openable window has been a problem in high-rise residential buildings to ventilate only through natural ventilation. Consequently, the installation of mechanical ventilation system has been a requirement in residential buildings, and has caused other problems such as increase of energy consumption and SBS. Hybrid ventilation which uses forces of both natural and mechanical power has been introduced to solve the problem of increase in energy consumption with natural ventilation. In this paper, two types of hybrid ventilation systems in residential building were introduced. One type was with natural ventilation through vent grille in the window, and another type was with natural ventilation through ceiling duct while both types used mechanical ventilation system with the outlets. The indoor temperature distribution and pollution density distribution in summer while operating the ceiling air conditioner were analyzed through CFD simulation. In this paper, the optimal location of diffusers to achieve thermal comfort would be proposed.

  • PDF

A Study on the Structural Relationships among Physical Environment of Coffee Shops, Brand Image and Revisit Intention : Focusing on the Moderating Effect of Emotional Responses (커피전문점의 물리적 환경, 브랜드 이미지 및 재방문의도 간의 구조관계 연구 : 고객 감정반응의 조절효과를 중심으로)

  • Kim, Young-Ja
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.7
    • /
    • pp.351-362
    • /
    • 2021
  • The purpose of this study is to examine the structural relationships among physical environment of coffee shops, brand image and revisit intention and to analyze the moderating effects of emotional responses. The results of this study are as follows: First, among physical environment, spatiality, cleanliness, comfortability and attractiveness had significant influences on brand image. Second, physical environment had significant influences on revisit intention. Third, brand image had significant influences on revisit intention. Fourth, emotional responses had moderating effects in the relationship between attractive factor and brand image. Finally, the conclusion section suggested strategic implications to induce physical environment, brand image, revisit intention and emotional responses based on the research findings.