Park, Mi-Ran;Choi, Nam-Ki;Lee, Young-Jun;Kim, Seon-Mi;Yang, Kyu-Ho
Journal of the korean academy of Pediatric Dentistry
/
v.31
no.2
/
pp.144-152
/
2004
The aim of this study was to evaluate the resistance to degradation of three commercial compomers in an alkaline solution. Dyract(Dentsply), Elan(Kerr) and F-2000(3M) polyacid modified resin composites(compomers) were used in this study. The resistance to degradation was evaluated on the basis of mass loss(%), degradation $depth({\mu}m)$ and Si, Al, Ba loss(ppm). The results were as follows : 1. The mass loss of each brand was $1.42%{\sim}2.14%$ and there was no statistically significant difference of mass loss among Dyract, F2000 and Elan. 2. The degradation layer depth of each brand was $182.92{\sim}227.7{\mu}m$ and there was no statistically significant difference of degradation layer depth among Dyract, F2000 and Elan. 3. There was statistically significant differences in Si-loss and Al-loss among three compomers (p<0.05). Si loss was the highest value in Dyract and Al loss was the highest value in F2000. 4. There was statistically significant correlation between mass loss and degradation layer depth (r=0.60, p<0.05). 5. In SEM finding, there was some destruction of compomer matrix-filler interface in post-exposure specimen to NaOH solution. As the matrix decreased, the filler particles distinguished and the periphery of the filler particles appeared whitish color due to degradation.
Journal of the korean academy of Pediatric Dentistry
/
v.29
no.4
/
pp.592-599
/
2002
Objective : The purpose of this study was to evaluate the effects of several light curing methods and several adhesives on the microleakage of composite resin restorations in primary teeth. Materials and methods : In 150 extracted human primary anterior teeth, O-shaped cavities were prepared in the labial surface ; the cavity diameter and depth were 1.6mm. The cavities were filled with light-activated composite resin, Compoglass. Four kinds of adhesives were used. Each filling materials were polymerized with three light cure methods. The restorations were polished using Sof-Lex discs(3M Co., USA). The samples were thermocycled 1,000 times between $5^{\circ}C$ and $55^{\circ}C$ with a 1-minute dwell time. Then, they were immersed in a 2% methylene blue solution(pH 7) for 12hours. Subsequently they were sectioned labio-lingually through the center of the restoration with a diamond saw at low speed with a water coolant, and evaluated by stereomicroscopy. Microleakage analyses were done, using scores from 0 to 4. Results : Results showed the least microleakage in Compoglass group(P<0.05). There were less microleakage in SBMP group among the adhesive groups, but no significant difference was observed(P>0.05). And there were no significant differences among the groups depending on curing methods(P>0.05).
Journal of the korean academy of Pediatric Dentistry
/
v.30
no.1
/
pp.161-170
/
2003
The aesthetic restorative materials are widely used in recent dentistry, showed not only the different quality between each component but also showed that the environment of the material has important effect on the physical properties of the material. Especially, when the restoratives are restored in the mouth, and since saliva is existing, the restoratives are always exposed to water and affected by the saliva. The purpose of this study was to research and compare the change of the degree of water sorption after water immersion of three types of the resin-based materials and the compressive strength, and observe the relation between the change of the water absorbing degree and the compressive strength. Z-100(3M, U.S.A) as a composite resin, F-2000(3M, U.S.A) as a compomer and Vitremer Restoratives(3M, U.S.A) as a resin-modified GIC were used, and each specimen was made to measure the water sorption and to evaluate the compressive strength. The specimens for measurement of the water sorption and the compressive strength were divided into 4 groups(1 day, 2 weeks, 4 weeks, and 8weeks). Each specimen was filled in the 30cc vial with 20cc of distilled water during the fixed amount of period in $37^{\circ}C$. The water sorption is decided by dividing the difference of weight before and after the immersion by the volume, and the compressive strength was measured by using the instron after the immersion. The following results were obtained ; 1. The more the water sorption increased, the more the immersion period of three restorative materials was long. And the most of water sorption was obtained during the first 2 weeks(P<0.001). 2. The water sorption of resin-modified GIC was higher than composite resin and compomer. 3. The more the compressive strength decreased, the more the immersion period of three restorative materials increased(composite resin and compomer: P<0.001, resin-modified GIC: P<0.05). Especially, the amount of the reduction in compressive strength of the composite resin was the highest. 4. The more the water sorption of all materials increased, the more the compressive strength decreased(P<0.05).
Kim, Sang-Hoon;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Park, Jeong-Yeol
Journal of the korean academy of Pediatric Dentistry
/
v.35
no.3
/
pp.418-426
/
2008
The objectives of this study were to examine the properties of fluoride-releasing resin composite restorative materials. Four commercially available compomer materials (Compoglass F: CF, $Dyract^{(R)}$ AP: DA, $Dyract^{(R)}$ flow: DF, F2000: FT) and one fluoride-releasing composite resin ($Tetric^{(R)}$ Ceram: TC) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. Disk-shaped specimens were fabricated in the split teflon mold with diameter of 15mm and thickness of 1mm. After curing for an hour, specimens were immersed in deionized water at $37^{\circ}C{\pm}1^{\circ}C$ for 30 days. All specimens were thermocycled for 10,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Toothbrush abrasion test was conducted under a load of 1.5 N and the abraded surfaces were examined with surface roughness tester (SV-3000, Mitutoyo Co, Japan) and SEM (JSM-5800, JEOL, Japan). Fluoride recharging was done by toothbrushing for 3 min. using a fluoride toothpaste (Perio Alpine Herb, LG Household & Health Care, Korea). The results obtained were summarized as follows; 1. The highest tensile strength value of 32.3 MPa was observed in TC group and the lowest value of 16.8 MPa was observed in CF group. The tensile strength of TC group was significantly higher than those of CF and DF groups (P<0.05). 2. The lowest Ra value of 0.287 was observed in TC group and the highest value of 1.516 was observed in FT group. The Ra value of FT group was significantly higher than other groups (P<0.05). 3. The abraded surfaces revealed the increase of surface roughness due to the protrusion and missing of filler particles. 4. The release of fluoride of compomers after tooth brushing by Perio Alpine Herb was initially large and then followed by small and continuously. But it remains small and constant in fluoride-releasing composite resin of TC. 5. The highest value of fluoride release after toothbrushing by Perio Alpine Herb was $2.064{\mu}g/cm^2$ in CF group and the lowest value was $0.1119{\mu}g/cm^2$ in TC group. The amount of fluoride release of CF group was significantly higher than other groups (P<0.05).
Restoration materials used to investigate effects of fluorine such as enamel strengthening and anti-caries effects in several types of dental restoration materials were five kinds including Ionoseal(VOCO GmbH, Cuxhaven, Germany), Fuji Filling LC(GC Co. Tokyo, Japan), Quadrant Universal LC(CAVEX Holland BV, Netherlands), PermaCem$^{(R)}$(DMG, Hamburg, Germany) and Dyract$^{(R)}$ AP(Dentsply GmbH, Germany), and the amount of fluorine-releasing was measured with ICS-5000 Reagent-FreeTM Ion Chromatography(RFICTM, Dionex, U.S.A.). The results of this study are as follows. 1. In all types of restoration materials, the amount of fluoride-releasing was reduced with time passage and it was declined sharply to show significance in four weeks. Fuji Filling LC(12.445PPM) or resin-reinforced glass ionomer and PermaCem$^{(R)}$(16.121PPM) or compomer were found to release fluorine for a long term(P<.001). 2. Ionoseal(0.887PPM) or glass ionomer and Quadrant Universal LC(0.957PPM) or composite resin released a few fluorine of 1PPM or less than 1PPM after one week, and Dyract$^{(R)}$ AP or compomer released fluorine of 8.631PPM in one week and its amount of releasing decreased dramatically in two and four week by recording 0.175PPM and 0.116PPM, respectively. Therefore, the effect of releasing fluorine in four weeks was observed to be poor (P<.001). 3. Fuji Filling LC or resin-reinforced glass ionomer and PermaCem$^{(R)}$ or compomer released fluorine of 33.372 and 1.902PPM, respectively in one week and their amount of releasing increased to be 36.371 and 18.223PPM, respectively in two weeks. So, their amount of fluorine-releasing recorded the highest levels in two weeks(P<.001).
복합레진에 의한 구치부 2급 와동의 수복에서 치은부 변연이 법랑-백아 경계 하방에 위치하는 경우 복합레진의 중합 수축에 의한 응력은 변연부의 폐쇄능력을 저하시키고 이로인한 미세누출은 2차적인 우식이나 술후과민증을 일으켜 임상에서의 성공을 위협한다. 본 연구에서는 2급 와동에서 복합레진으로 수복하기 전에 치은 변연부를 중합수축에 의한 응력을 완화시킬 수 있는 것으로 알려진 몇가지 재료들을 중간층으로 먼저 충전한 후 충전용 복합레진으로 충전한 뒤 치은부 변연에서 이들 중간층과 치질 사이의 미세누출의 정도를 비교하였다. 20개의 발거된 구치의 근, 원심면에 각각 상자 모양의 2급 와동을 형성하고 40개의 와동을 무작위로 10개씩, 4개의군으로 나누었다. 1군은 중간층의 수복없이 Clearfil SE Bond과 Clearfil AP-X로 충전하였으며 2, 3 및 4군은 중간층으로 각각 Revolution, Dyract그리고 FujiII LG를 먼저 충전한 후 1군과 동일한 방법으로 복합레진을 충전하였다. 충전된 시편은 열순환후 2% methylene blue 용액에 12시간 침잠시킨 후 색소의 침투도를 stereomicroscope로 관찰하였으며 실험결과는 Kruskal-Wallis non-parametric independent analysis 및 Mann-Whitney U test로 통계분석하여 다음의 결론을 얻었다. 1. 레진강화형 글라스아이오노머를 중간층으로 먼저 수복하고 복합레진으로 충전한 경우에서 더 적은 미세누출을 보였다(p<0.05). 2. 유동성 레진과 콤포머를 중간층으로 수복한 경우와 복합레진만으로 수복한 경우는 미세누출에 있어서 유의한 차이를 나타내지 않았다(p>0.05).
The aim of this study was to evaluate the effect of various polymerization techniques on the microleakage of compomer restorations. Fifty extracted human premolars and molar were used and randomly divided into 5 groups. After cavity preparation, compomer (F2000$^{\circledR}$) was filled according to the manufacturer's directions. All groups, except group 5, were filled using an incremental technique. Group 1 was polymerized for 40 seconds at a continuous 485mW/$\textrm{cm}^2$ with a VIP$^{\circledR}$(Bisco, USA) light cure unit. Group 2 was polymerized for 20 seconds at 345mW/$\textrm{cm}^2$ and then for 20 seconds at 645mW/$\textrm{cm}^2$ with the VIP equation omitted light cure unit. Group 3 was polymerized at 400mW/$\textrm{cm}^2$, gradually increased to 50mW/$\textrm{cm}^2$ 10 seconds until 550mW/$\textrm{cm}^2$ was reached; total 40 seconds with a Spectrum 800$^{\circledR}$ (Dentsply Caulk, USA) light cure unit. Group 4 was polymerized for 3 seconds using an incremental technique with a Flipo$^{\circledR}$ (LOKKi, France) light cure unit. Group 5 was polymerized for 3 seconds using a bulk fill technique with the Flipo$^{\circledR}$ light cure unit. The specimens were embedded with acrylic resin, and were sectioned with diamond saws in a mesiodistal direction along the longitudinal axis of the tooth so as to pass through the center of the restoration, and three surfaces (occlusal, pulpal, and gingival) were examined with SEM. The results were as follows ; 1. Group 5 showed a significantly larger gaps compared to other groups on the gingival, occlusal, and pulpal walls. 2. All groups except group 5 had no statistically significant gap on the gingival, occlusal, and pulpal walls. 3. There was no significant correlation between the amount of enamel on the gingival and occlusal walls and polymerization shrinkage.
The color of an esthetic restorative material is controlled primarily by thickness of the material and background color. Although the effects of the two factors on the color coordinates of esthetic dental materials have been reported, the mechanism has not been clarified well enough to explain the effects quantitatively. The purpose of this study was to evaluate the effect of thickness and background color on the color of tooth colored restorative materials quantitatively. One hundred sixty samples were fabricated from two commercial light-cured composite resins and two commercial compomers. The color characteristics and changes in the color coordinates were measured by a tristimulus colorimeter (Model TC-6FX, Tokyo Denshoku Co. Japan) using the CIELAB system. The results were as follows: 1. As thickness increased from 1.0 to 4.0mm, values of $L^*$$a^*$$b^*$ changed irregulary for white and dentin color background, but showed no obvious difference in color for black background. 2. The colors of composite resins and compomers were significantly influenced by background color. 3. The color difference was recognized even the same shade name in four representative kinds of composite resins and compomers. 4. As thickness changed, values of color difference for same products and same background color showed constancy, but showed difference for different background color.
In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.
Kim, Young-Jin;Lee, Ju-Hyun;Seo, Hyun-Woo;Park, Ho-Won
Journal of the korean academy of Pediatric Dentistry
/
v.33
no.4
/
pp.653-660
/
2006
Fuji VII is a glass-ionomer cement specially targeted for early protection in erupting first and second molars. Properties of Fuji VII such as very high level of fluoride release, low viscosity and no need to preliminarily etch the substrate would be useful to erupting molars with primary pit and fissure caries or hypoplastic area for preventive goal or remineralization. The purpose of this study were to evaluate remineralization of Fuji VII glass ionomer cement and to compare with one of other restorative materials such as conventional glass ionomer cement, resin-modified glass ionomer cement, compomer and composite resin. Forty-two extracted human molars were used for this study. All teeth were immersed in demineralizing solution for 48 hours after Class V cavity preparation was made on sound proximal surface. The teeth were randomly divided into six groups and restored with Fuji VII, Fuji II, Fuji II LC improved, F2000, $Filtek^{TM}$ Z250 and control group was unrestored. The middle area with $130{\pm}20{\mu}m$ thickness was separated from specimen using microtome and demineralized area was photographed under polarized microscope. Separated area was relocated to specimen and stored in artificial saliva, After four weeks, changes of demineralized area were observed and compared to them restorated immediately. The results from the this study can be summarized as follows ; 1. Fuji VII, Fuji II, Fuji II LC improved have more prominent remineralization effect than F2000, $Filtek^{TM}$ Z250, control group. 2. No significant differences in remineralization effect are seen between Fuji VII and Fuji II, Fuji II LC improved.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.