• Title/Summary/Keyword: 콘 칼로리미터

Search Result 158, Processing Time 0.022 seconds

A Combustion Characteristic Analysis of PMMA by Cone Heater of the flexible Heat Flux (콘 히터의 유동적인 열선속을 적용한 PMMA의 연소 특성 분석)

  • Moon, Sung-Woong;Ryu, Sang-Hoon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.39-44
    • /
    • 2010
  • The cone calorimeter method which is currently used to measure the heat release rate has a fixed rate of radiation. However, in the real fire, when flame combustible material burns, it releases the identical heat flux. We measured the changes of temperature of a fire using FDS in order to analyze flexible heat flux of combustion characteristics. In this study, the rate of radiation of cone calorimeter was adopted by using FDS. Follow those results, it produce between the rate of radiation in the growth period and decline period have a significant impact on heat release rate of PMMA.

A Fire Resistance Property Study of Architectural Fabric using Cone Calorimeter (콘칼로리미터를 이용한 건축용 막재의 내화 특성 연구)

  • Kim, Ji-Hyeon;Shin, Hyeon-Uk;Song, Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.158-159
    • /
    • 2015
  • Architectural fabrics are now used in membrane structure with the merits of free shape, lightness and opened up new possibility for the design of new building structures. Recently PVC, PVF, PVDF, PTFE coated fabric for using the membrane structures. However, clear standards for the design and construction is not exist because of the lack of Architectural fabric research. In this paper, Flammable properties of PVDF, PTFE coated fabrics are obtained through the Flammability test using the Cone Calorimeter. Based on these results, identify the fire resistance property of the Architectural fabric.

  • PDF

Comparison with Combustion Properties of Wood-Plastic Composites (Wood-Plastic Composite의 연소특성 비교)

  • Song, Young-Ho;Shin, Baek-Woo;Lee, Dong-Ho;Chung, Kook-Sam
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.251-256
    • /
    • 2010
  • 주거 건축 및 가구산업의 자재로써 합성목재(Wood-Plastic Composites)는 점차 각광받고 있다. 본 연구에서는 합성목재의 연소특성을 살펴보기 위하여 한계산소지수 측정(ASTM D2863) 및 콘칼로리미터 시험(ISO 5660-1)을 실시하였으며 또한 일반목재인 적송(red pine)과 방부 처리를 한 방부목에 대하여도 동일한 시험을 통하여 합성목재와 연소특성을 비교 검토하였다. 한계산소지수 측정결과 합성목재가 적송 및 방부목에 비해 가장 낮게 측정되었다. 콘칼로리미터 시험결과 합성목재의 열방출률값이 가장 빨리 피크치에 도달하였고 점차적으로 감소하였다. 합성목재의 최대 열방출률 값 및 평균 열방출률 값은 적송 및 방부목에 비해 가장 높게 나타났으며 총 방출열량 또한 가장 높게 나타났다.

  • PDF

Flame Retardancy and Foaming Properties of the NBR/Ground Tire Rubber Foams Containing Expandable Graphite (팽창 흑연을 포함한 NBR/GTR 발포체의 난연 및 발포특성)

  • Moon Sung-Chul;Choi Jae-Kon;Jo Byung-Wook
    • Polymer(Korea)
    • /
    • v.28 no.5
    • /
    • pp.412-425
    • /
    • 2004
  • The influence of expandable graphite (EG) on flame retardancy and foaming properties of the NBR/GTR foams was studied. The foaming properties were similar to those of NBR/GTR foams without EG when the EG contents were 10$\~$30 phr. The LOI values were increased with the EG content. For cone-calorimeter test, the data showed the trend similar to that from experiment. When the composition ratios of the compounds of NBR/GTR were 100$\~$0/80$\~$20 (w/w), and the EG contents were 10$\~$30 phr, we obtained high flame retardancy foams with low heat release rate (HRR), total heat release (THR), effective heat of combustion (EHC) and carbon monoxide yield (COY). The smoke density is similar to CO yield values obtained by the cone-calorimeter test. TGA analysis also showed the results approximately similar to those from the LOI and cone-calorimeter experiments.

A Study on the Cone Calorimeter Evaluation Method of Sandwich Panels (복합자재 콘칼로리미터평가방법에 대한 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.74-82
    • /
    • 2017
  • Fires in buildings built using sandwich panels are difficult to extinguish, and the damage caused by the fire spreading through the inner core material is extensive. Sandwich panels consist of a nonflammable material on both sides of an insulation material. The types of insulation material include organic and inorganic insulation materials, but the former are used in more than 80% of the case. Organic insulation is economically advantageous compared to inorganic insulation, but it is vulnerable to fire. Therefore, the damage caused by sandwich panel fires is higher than that for general fires. In the case of the noxious gas analyzer test, the panel is tested with three round holes having a diameter of 25 mm, in order to determine the risk of the core material, but the cone calorimeter test is carried out using a sandwich panel. In this study, the cone calorimeter test was conducted to examine the fire risk of the composite material when heated on a nonflammable surface, exposed to the core material through a hole, and heated directly the core material. The type of organic insulation employed was flame retardant EPS (Expanded Polystyrene), and the test specimens were tested in three types of sandwich panel, a perforated sandwich panel and single core material. The purpose of this study is to propose a method of measuring the fire risk of the core materials of composite materials using the cone calorimeter test.

Fire Resistance Study of PP Thermoplastic Composites with Particulate Reinforcements and Br Flame Retardants (무기 입자 강화제와 브롬(Br) 난연제에 따른 폴리프로필렌 복합재료의 난연성 향상에 관한 연구)

  • 곽성복;황성덕;남재도;고재송;최형기
    • Polymer(Korea)
    • /
    • v.26 no.2
    • /
    • pp.260-269
    • /
    • 2002
  • The fire resistance of particulate polypropylene composite systems were investigated by using various reinforced particles such as zeolite, talc, $CaCO_3$ particles. In this study, The effect of particle size on the thermal properties of composite and the effect of reinforced particles on the fire resistance were studied. The inorganic reinforced particles used in this study were recycled zeolite(average particle diameter=85.34 $mu extrm{m}$), $CaCO_3$ (33.93 $mu extrm{m}$), and talc (18.51 $mu extrm{m}$). The fire resistance of composite systems was thoroughly examined by measuring limited oxygen index (LOI, ASTM D2863) and cone calorimetry (ASTM E1354, ISO 5660). Thermal stability of composite systems was thoroughly examined by measuring TGA. The flame retardants (DBDPO) and reinforced particles reduce the maximum heat release rate (M-HRR) in the order of Talc > $CaCO_3$ > recycled Zeolite. Comparing the cone calorimetry experimental results of the particle reinforced polymer composite system exhibited twice higher efficiency than DBDPO in polypropylene systems, and the LOI also showed similar trends to the cone calorimetry experiments. The optical and scanning electron microscopy techniques were used to investigate the composites ash layer and the core fracture surfaces in the burning process. The reinforcing inorganic particles seemed to accumulate at the surface of ash layer, and subsequently intercept the oxygen transport and heat transfer into the core area.

Evaluation of the Burning Properties of Various Carpet Samples by using the Cone Calorimeter and Gas Toxicity Test (콘칼로리미터와 가스유해성 시험법을 이용한 카페트류의 연소특성 평가)

  • Lee, Bong-Woo;Kwon, Seong-Pil;Lee, Jang-Won;Lee, Byoung-Ho;Kim, Hee-Soo;Kim, Hyun-Joong
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.1-9
    • /
    • 2009
  • In this study, the burning behaviours of five different kinds of carpet samples covered with nylon, PP (polypropylene), PTT (poly(trimethylene terephthalate)), wool fabric and NW (nylon and wool) were evaluated by using the cone calorimeter having a radiant flux of 50kW/$m^2$. And the combustion gas toxicity was evaluated according to KS F 2271 test method. As a result of the cone calorimeter test (KS F ISO 5660-1), nylon carpet samples were ignited most easily. In ignition ability or initial flammability, NW carpet samples showed the highest value. In heat release rate (HRR), fire intensity, PP carpet samples were larger than any other samples. Nylon carpet samples were the highest smoke production rate, while N/W carpet samples the lowest. The following were in mass loss rates: NW > wool > nylon > PP > PTT. CO (carbon monoxide) was one of the most toxic gases released from the combustion. PTT carpet samples gave rise to the highest CO concentration, while NW carpet samples the lowest. In addition, PP carpet samples caused the highest $CO_2$ (carbon dioxide) concentration, while NW carpet samples the lowest. Toxicity of the gas produced from carpet samples was determined by the mouse stop motion, and it resulted in the fact that the combustion gas of PTT carpet samples was more toxic than that of any other samples.