• Title/Summary/Keyword: 콘크리트용 앵커

Search Result 35, Processing Time 0.03 seconds

Pullout Tests on M12&M20 Stainless Steel Post-Installed Expansion Anchor for Seismic Design in Cracked Concrete (균열 콘크리트에 설치된 M12, M20 내진용 스테인리스스틸 확장식 후설치 앵커 인장 실험)

  • Kim, Jin-Gyu;Chun, Sung-Chul;An, Yeong-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.29-38
    • /
    • 2022
  • Recently, seismic design for anchors is required, which are used for connecting structural members and non-structural and structural members. In this study, pull-out tests on the new expansion anchors which have been developed for cracked concrete. The anchors of 12 mm and 20 mm diameters were tested which are commonly used. Experiments were conducted on non-cracked concrete and cracked concrete to evaluate the seismic performance of the post-installed anchor. The experimental method complies with the specified test protocol (KCI, 2018). Three experimental variables are included in this study: presence of cracks, concrete compressive strength, and effective embedment depth. The strength of the anchors was evaluated with the characteristic capacity K5% determined from the test results incorporated with the safety of 5% fractile. The characteristic capacity K5% of the non-cracked and cracked concrete specified in KDS 14 20 54 are 9.8 and 7.0, respectively. Test results show that all groups except the three groups have higher characteristic capacity K5% than the KDS code and the nominal strengths of the tested anchors can be determined with the obtained characteristic capacity K5%.

An Experimental Study on Pullout Characteristics of Post-installed Set Anchor for Concrete under Edge Distance, Anchor Interval and Concrete Strength (연단거리, 앵커간격 및 콘크리트 강도에 따른 콘크리트용 후설치 세트앵커의 인발특성에 관한 실험적 연구)

  • Suth, Ratha;Yoo, Seung-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2469-2475
    • /
    • 2014
  • In 1990s, with the increase of domestic building renovation but also increase the amount of anchor. The 45-degree cone failure theory has been used in concrete anchor bolts design, but the CCD (concrete capacity design) method was adopted as a new design method since 2000. However, the method has some problems because it is based on the experimental results of pre-installed concrete anchor bolts. In this study, the objective is to investigate the effects of anchor edge distance, anchor interval and concrete strength on pullout characteristics of post-installed concrete set anchor embedded in plain concrete.

An Experimental Study on the Shear Failure Behavior of Post-installed Set Anchor for Concrete (콘크리트용 후설치 세트앵커의 전단파괴거동에 관한 실험적 연구)

  • Um, Chan-Hee;Yoo, Seung-Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.367-375
    • /
    • 2014
  • Recently the use of concrete post-installed set anchors has been increasing because this constructing method is flexible and easy to attach or fix structural members when we repair, reinforce, or remodel a concrete structures. Depending on the shear strength of steel, the strength of concrete, edge distance and anchor interval, etc, the anchor loaded in shearing exhibits various failure modes such as steel failure, concrete failure, concrete pryout. In this study, the objective is to investigate the effects of the variations like anchor embedment depth, anchor interval, edge distance and concrete strength on the shear failure behavior of post-installed concrete set anchor embedded in concrete. The results of embedment depth experiments show that concrete strength has much effection on the shallow embedment depth. Steel failure occur to all results of the anchor interval experiments, but concrete is failed when edge distance experiments that less than the embedment depth. Through the comparision of the same parameters experiments results show that as strong as concrete strength are the displacement results are small.

A Fundamental Study on the Pullout Strength Equation of High Strength Anchor for Asphalt Pavement (아스팔트용 고강도 앵커시스템의 인발강도식 검토에 관한 기초적 연구)

  • Choi, Jaemin;Lee, Seungyong;Sung, Kitae;Han, Youngdoo
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.313-321
    • /
    • 2017
  • In order to investigate the basic performance of the high strength anchor for asphalt road subjected to tensile load, the static pullout test was carried out and the pullout strength of the asphalt anchor was analyzed. In the pullout test, the depth of anchor, depth of pavement, diameter of anchor, type of anchor, experimental temperature, epoxy type and amount of anchor were used as test variables. As a result, the steel strength of asphalt anchor was 1.08 times higher than that of conventional concrete anchor, therefore it is considered appropriate to use the steel strength formula of concrete anchor for asphalt anchor. Compared with the proposed formula, the pullout load obtained from the test of the asphalt anchor was within ${\pm}10%$. The ratio of the projected area of the asphalt anchor is similar as that of the concrete anchor.

Tensile and shear test method for post-installed mechanical anchors embedded in concrete (콘크리트 매입 후설치 앵커의 인장 및 전단시험방법)

  • Lee, Kwang-Myong;Lee, Chin-Yong;Jung, Sang-Hwa;Choi, Seul-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.97-98
    • /
    • 2009
  • In this study, tensile and shear test method for post-installed mechanical anchors embedded in concrete was proposed and the verification test was carried out to evaluate the design strength of anchor.

  • PDF

Nonlinear Tensile Behavior Analysis of Torque-controlled Expansion Anchors Using Finite Element Analysis (유한요소해석을 활용한 비틀림 제어 확장앵커의 비선형 인장거동 특성 분석)

  • Bang, Jin Soo;Youn, Ilro;Kwon, Yangsu;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.91-99
    • /
    • 2020
  • Post-installed anchors were widely used due to its workable benefits. Regarding the resistance performance of anchors, the critical edge distance is presented to minimize the impact of concrete splitting. In the case of actual anchors, however, it is difficult to obtain the ideal edge distance. The purpose of this study is to identify resistance performance and behavior characteristics that contain complex elements such as concrete crack occurring under tensile load. Tensile tests were conducted based on the standard method. Failure shape and the resistance characteristics that do not have the critical edge distance were derived by tensile load. Parametric analysis according to the boundary condition was performed to simulate the actual tensile behavior, through a nonlinear finite element model based on the specimen. Consequently therefore, verifying analysis results the resistance mechanism can be applied through boundary conditions.

A Parameter Study on the Shear Failure Behavior of Post-installed Set Anchor for Light Load (저하중용 후설치 세트앵커의 전단파괴거동에 관한 매개변수 연구)

  • Um, Chan-Hee;Yoo, Seung-Woon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.55-63
    • /
    • 2015
  • Post-installed concrete set anchors are installed after the concrete hardened. These anchors increasing usage in development of construction equipment and flexible construction. The anchor loaded in shearing exhibits various failure modes such as steel failure, concrete failure, concrete pryout, depending on the shear strength of steel, the strength of concrete, edge distance and anchor interval, etc,. In this study, the objective is to investigate the effects of the variations like anchor embedment depth, edge distance and concrete strength on experimental and finite element analysis of shear failure behavior of post-installed concrete set anchor for light load embedded in concrete. The results of embedment depth experiments show that concrete strength has much affection on the shallow embedment depth. Concrete strength has no much affection with anchor interval and edge distance parameter and both experimental results occurred same failure mode. By comparing the experimental results that occurred steel failure mode show that as strong as concrete strength are the displacement results are small.

A Study on the Concrete Breakout Capacity Evaluation of Medium-to-Large size CIP Anchor Bolts under Tension Loading (인장하중을 받는 중대형급 선설치 앵커볼트의 콘크리트파괴강도 평가를 위한 연구)

  • Park, Yong-Myung;Jeon, Myeong-Hui;Lee, Kun-Jun;Kim, Cheol-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.493-501
    • /
    • 2011
  • The $45^{\circ}$cone failure theory has been used for concrete anchor bolt design, but the CCD (concrete capacity design) method was adopted as a new design method in 2000. The method was allowed to be used, however, only for anchors with a diameter of less than 50 mm and an embedment depth of less than 635 mm because it is based on the experiment results from medium-sized to small anchor bolts. Therefore, it is necessary to develop a rational concrete breakout capacity equation for medium-sized to large anchor bolts. In this study, tension tests on an M56 cast-in-place single anchor bolt with an effective embedment depth of 400-450 mm were carried out for the five test specimens. Based on the test results together with the other recent test results, the applicability of the concrete breakout capacity equation in the current design code to the large to medium-sized anchor bolts with an embedment depth of 280-1,200 mm was estimated.