• Title/Summary/Keyword: 콘덴싱 가스보일러

Search Result 19, Processing Time 0.026 seconds

A Study on Prevention of Accidents of Carbon Monoxide Leak from Gas Boilers (가스보일러 일산화탄소 누출사고 경감에 관한 연구)

  • Song, Jaechang;Kwon, Hweeung;Lee, Younghee;Moon, Il
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.277-281
    • /
    • 2012
  • This work is concerned with a plan for preventing accidents of CO gas leak from gas boilers, involving the enforcement of installations of both CO alarm system and condensing boilers, and financial support of government grants. If amongst 1,460,000 beneficiaries of basic livelihood security, one million households in use of gas boilers receive 3-year support of 200,000 won, the difference of prices between common and condensing boilers, the government grants would be 2,000 billion won. If 3 million common householders are in 3-year support of 100,000 won, government grants would be 3,000 billion won. Therefore, 3-year grand total of government grants would be 5,000 billion won. Finance for government grants can be purveyed from energy saving; yearly 2,000 billion won of energy saving by enforcing to replace one million existing boilers with condensing boilers, leading to 2 trillion won of energy saving for 10 years. In this way, 6,000 billion won of 3-year grand total of government grants for CO alarm system and condensing boilers can be purveyed. The rest amount would be fundraised for energy savings. We claim that our proposal can make an achievement of more than 50% reduction of CO leak accidents during 10 years.

Development of the Catalytic Combustion Condensing Boiler of Lower Emission Type for Domestic Use (저공해형 촉매연소식 소형 콘덴싱보일러 개발)

  • Kim Hoyeon;Lee Seungho;Cho Wonihl;Baek Youngsoon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.45-51
    • /
    • 2001
  • Catalytic combustion is the environmental-friendly technology, which has been applied to a variety of areas for industrial and domestic use in recent years. Accordingly, this study performed the development of the catalytic manufacturing technology for the high temperature and of the catalytic combustor in priority, which were aimed to be aimed to a commercialized condensing boiler. Palladium(Pd) of a noble meta] was used as a catalyst for the high temperature and supported on $alumina(Al_{2}O_{3})\;and\;zirconia(ZrO_2)$ in constant weight ratio. Activity of Pd catalysts is compared and analysed in the catalytic combustion of natural gas. The ratio of $Pd/Al_{2}O_{3}\;=\;4$ was found to be better than any other weight ratios in activity and durability. The performance examination of catalysts and of combustion through the plate-type combustor made it possible to be developed the cylindrical-type combustor which has increased combustion area. Catalytic combustion condensing boiler of 25,000 kcal/hr class was also developed, which had the optimum combustion condition at the no221e of 5.95mm and the orifice of 21mm. This condition was determined through the performance experiments of catalytic combustion condensing boiler to which the cylindrical-type catalytic combustor was applied.

  • PDF

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

The Optimization of Cylindrical Perforated Burner for Condensing Gas Boiler (콘덴싱 가스보일러용 원통형 다공버너의 최적화 연구)

  • 이창언;장기현;이강주;정영식
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • The objective of performing this study is to develop low emission condensing gas boiler. To reduce NOx and CO, three reasonable distances between burner and heat exchanger were decided through the experiments of model plane burner. Three burners with different diameter were made and then emission characteristics were examined. The optimum burner geometry was determined from flame stability, pollutant emission characteristics and applicability to the practical boiler system. In the domain of equivalence ratio 0.68~0.85, turn-down ratio of the burner designed by this research was extended to a wider range of 5 : 1. Thermal efficiency of the boiler developed by this study reached to 97% (LHV basis) of heating water efficiency at heating load of 20,000 kcal/hr when fueled by both of LNG or LPG. Emission ($O_2$=0%, wet basis) of NOx and CO concentration was 26 ppm and 85 ppm when fueled by LNG, 41 ppm and 113 ppm when fueled by LPG respectively.

The Supply Water Algorithm for a Condensing Gas Boiler Control (콘덴싱가스보일러 제어를 위한 공급수알고리즘)

  • Han, Do-Young;Yoo, Byeong-Kang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.441-448
    • /
    • 2011
  • The energy consumption of a condensing gas boiler may be greatly reduced by the effective operation of the unit. In this study, the supply water algorithm for a condensing gas boiler control was developed by using the fuzzy logic. This includes the supply water set temperature algorithm, and the control algorithms of a gas valve, a blower and a pump. For the set temperature algorithm, the outside air temperature and the return water temperature were used as input variables. The supply water temperature difference and its slope were used as input variables of the gas valve and blower control algorithm. And the supply water temperature and the return water temperature were used as input variables of the pump control algorithm. In order to analyse performances of these algorithms, the dynamic model of a condensing gas boiler was used. The initial start-up test, the supply water set temperature change test, the outside air temperature change test, and the return water temperature change test were performed. Simulation results showed that algorithms developed in this study may be practically applied for the effective control of a condensing gas boiler.

Characteristics of Combustion and Thermal Efficiency for Premixed Flat Plate Burner Using a Porous Media (다공성 소재 종류에 따른 예혼합 평판버너의 연소 및 열효율 특성에 관한 연구)

  • Kum, Sungmin;Yu, Byeonghun;Lee, Chang-Eon;Lee, Seungro
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.385-392
    • /
    • 2012
  • The purpose of this study is investigated on the combustion and the thermal characteristics of porous media burners which are many using for a condensing boiler recently. In addition, results of this study will be used the fundamental information to decide the burner type which will be applied to the future development of EGR(Exhaust gas recirculation) condensing boiler. Two flat type of burners made of a the metal fiber(MF) and the ceramic(CM) were selected and examined, experimentally. As experimental results, the emitted CO concentration of CM was higher than that of MF. However, the NO concentration of MF was higher than that of CM. The efficiencies of both burners were increased as increasing the burner capacity. While the efficiency of MF was higher than that of CM, regardless of the burner capacity. In the experimental range, MF is appropriated for the burner material and 0.8 of equivalence ratio is an optimal operation condition, regarding of the proportional control, the thermal efficiency and emitted NO and CO concentration based on the regulations of KS B standard and EN 677 standard.

The Study on the Optimization of Premixed Gas Burner and Heat Exchanger (예혼합 가스버너와 열교환기의 최적화 연구)

  • Lee Kang Ju;Jang Gi Hyun;Lee Chang Eon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.4 s.21
    • /
    • pp.7-13
    • /
    • 2003
  • This study was carried out to optimize premixed burner and heat exchanger of the condensing gas boiler which can save energy by utilizing latent heat of combustion gas and reduce pollutant in exhaust gas. The heat exchanger of the gas boiler was composed of three parts, which were an upper, lower, and coil heat exchanger. The upper heat exchanger was placed outside of the premixed burner and a lower heat exchanger was located under the upper heat exchanger. And, coil heat exchanger rounded the outer surface of an upper and lower heat exchanger. The boiler designed by this research reaches turn-down ratio 4:1 in the domain of equivalence ratio 0.75${\~}$0.8 and thermal efficiency of $97\%$. Emission of NOx and CO concentration was under 20ppm and 140ppm at equivalence ratio 0.8. When diameter of the burner is replaced from 60mm to 50mm, emission of CO was reduced about 50ppm remarkably.

  • PDF

Boiler Supply Water Temperature Setting by Outside Air Temperature and Return Water Temperature (외기온도와 환수온도를 이용한 보일러의 공급수온도설정)

  • Han, Do-Young;Yoo, Byeong-Kang
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.161-166
    • /
    • 2009
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a boiler unit, the effective operation is necessary. In this study, the supply water temperature algorithm of a condensing gas boiler was developed. This includes the setpoint algorithm and the control algorithm of the supply water temperature. The setpoint algorithm was developed by the fuzzy logic and the control algorithm was developed by the proportional integral algorithm. In order to analyse the performance of the supply water temperature algorithm, the dynamic model of a condensing gas boiler system was used. Simulation results showed that the supply water temperature algorithm developed for this study may be practically applied for the control of the condensing gas boiler.

  • PDF