• Title/Summary/Keyword: 코어 비저항

Search Result 68, Processing Time 0.027 seconds

Resistivity Monitoring of Saturated Rock Cores at Room Temperature (수포화 암석코어의 상온 전기비저항 모니터링)

  • Lee, Sang Kyu;Lee, Tae Jong;Yi, Myeong-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.105-114
    • /
    • 2015
  • A long-term resistivity monitoring system has been developed for saturated cores in room temperature and humidity condition. A 3-channel water-pump continuously drops the water onto the top of saturated core sample surrounded by shrinkable tube as well as on the paper filters of the electrodes at both sides of the core sample, by which one can monitor the resistivity changes with maintaining full saturation of the rock core for a week or longer. Monitoring the resistivity changes has been performed with 3 kinds of rock samples including biotite gneiss, andesitic tuff, and shale for 9 days using the system. Consequently, it is proposed two hypothesis that conversion speed of temperature coefficient has close relation to the thermal properties of the rock sample and that the ratio of resistance between dry and saturated conditions for a rock sample can be related to the effective porosity of the sample. The ratio between dry and saturated resistance for the three rock types are 48, 705, and 2, while effective porosity was 3.7%, 3.3%, and 13.0%, respectively.

Structural-Health Evaluation for Core Zones of Fill Dams in Korea using Electrical Resistivity Survey and No Water Boring Method (전기비저항 탐사와 무수보링을 이용한 국내 필 댐 코어존의 건전성 평가)

  • Lee, Sangjong;Lim, Heuidae;Park, Dongsoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.21-35
    • /
    • 2015
  • Electrical resistivity survey (2D and 3D) were employed for detection of possible weak zone of core zones of three central core earth-rockfill dams in Korea. In the 2D results, the core zones is lower resistivity zone with less than $50{\sim}400ohm{\cdot}m$, and the basement is relatively higher resistivity zone with over $1,000ohm{\cdot}m$. In the 3D results, especially, the weak zone with under $100ohm{\cdot}m$ was detected spatial distribution area in the dam. We also drilled boreholes to collect soil samples of core zones of each dam. Water was not used during boring, because water for rotary wash boring could cause structural damages in earth dams. We found that the soil samples of core zones from all of the boreholes correspond to CL (USCS), but we also found that the fluidized or water-saturated soil samples were found in lower resistivity zones. Therefore, the electrical resistivity survey and drilling method without water are a quick and efficient method for structural-health evaluation which is detection of possible weak zones in earth core rockfill dams.

Analyses of Structural Behaviors According to Core Location in the Building with Symmetric Plan (대칭 평면형 건물에서의 코어위치에 따른 구조거동 분석)

  • Kim, Jung-Rae;Kim, Jae-Yo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.116-124
    • /
    • 2020
  • In order to analyze the lateral-load resisting capability according to the core locations, three-dimensional structural analyses were performed for 20-story buildings with symmetric plan. Four analytical models for a center core, a single-axial eccentric core, and a double-axial eccentric core were constructed, and eigenvalue analyses, wind-load analyses, and earthquake-load analyses were performed. Torsion did not occur in the central core building, but the bending and torsion occurred in combination with the arrangement of the eccentric core, and the lateral-load resisting capability was degraded. The change in the wind load according to the eccentric core was small, but the maximum lateral displacement was found to increase greatly by the eccentric arrangement of the core. In addition, in case of the eccentric core, the seismic load was slightly reduced compared to the center core due to the decrease in the lateral stiffness, but it was found that the maximum story drift ratio increased significantly due to the torsional effect. Based on these results, the structural behavior according to the position of the core can be clearified and used as a guideline for core locations in the planning and design stage.

Electrical Resistivity at Room Temperature and Relation between Physical Properties of Core Samples from Ulleung Island (울릉도 시추 코어의 상온 전기비저항과 물성 간의 상관성)

  • Lee, Tae Jong;Lee, Sang Kyu;Yun, Kwan-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.4
    • /
    • pp.171-180
    • /
    • 2015
  • Electrical resistivity of 23 core samples from Ulleung Island at dry or saturated condition has been measured along with dry density and effective porosity, and the relations between the properties has also been discussed. Upper and lower bounds of electrical resistivity at room temperature can be provided by the dry- and saturated-resistivity, respectively. Injecting nitrogen gas to the pore space at the very end of drying process can prevent humid air from getting into the pore space, so that measurement of dry-resistivity can be less affected by humidity in the air. Dry density and porosity have very close correlation; the ratio between increase of porosity and the decrease of density showed distinct relation to the rock types, such that basaltic rocks showed higher ratio while trachytic rocks showed lower. Saturated resistivity showed close correlation to density and effective porosity of the rock sample, while dry resistivity didn't.

Experimental Verification on Factors Affecting Core Resistivity Measurements (II)-Characteristics of Time Series Data and Determination Method of Resistivity (코어비저항 측정에 미치는 영향요소에 대한 실험적 고찰(Ⅱ) - 시계열자료의 특성과 대표비저항 값의 결정)

  • Kim, Yeong Hwa;Choe, Ye Gwon
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.4
    • /
    • pp.269-276
    • /
    • 1999
  • As a part of trying to get the resistivity values correctly from laboratory core resistivity measurement, the effect of sample holders in resistivity measurement was analyzed and a better way to determine the representative resistivity value from the time series resistivity data was searched. Modified GS type and modified two-electrode type sample holders were devised and their effects have been compared with those of GS and two-electrode type sample holders. The modified two-electrode type sample holder has benefits both in repetition and simplicity in data acquisition. The analysis of distribution trend of the time series resistivity data obtained with different kind of sample holders and source frequencies shows that the maximum curvature point method gives the best result in determining representative resistivity value.

  • PDF

Experimental Verification on Factors Affecting Core Resistivity Measurements (코어 비저항 측정에 미치는 영향요소에 대한 실험적 고찰)

  • Kim, Yeong Hwa;Choe, Ye Gwon
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.225-233
    • /
    • 1999
  • Electrical resistivity of a rock-sample is dependant on not only formation factor of rock itself but also many parameters such as fluid type, measuring device, temperature, water saturation, electrical contact between electrode and core section, induced polarization, and frequency of electric source. In this study, we attempt to verify various affecting factors in core resistivity measurements and to find a better environment for core resistivity measurement. Particularly great attention has been paid to understanding the effects of temperature, water saturation, contact condition between sample and electrodes, and frequency of electric source. Precise measurement of resistivity can be achieved by utilizing silver paste for better contacts, taping samples for constant moisture contents, and using time-series resistivity data.

  • PDF

The Prototype Study of Resistivity and Porosity Measurement for the Samples Collected Near Marine Hydrothermal Deposit (해저열수광상 주변 암석 시료의 공극률과 전기비저항 측정 기초실험)

  • Lee, Sang-Kyu;Lee, Seong-Kon
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.378-387
    • /
    • 2010
  • We present the results of laboratory measurement of porosity and electrical resistivity for the samples collected near marine hydrothermal deposit to provide fundamental perspective of physical properties for future electromagnetic survey. The rock cores are sampled from the host rock, pumice, hydrothermal altered zone, and chimney. These samples are featured as easily brittle, rough surface with large pores, having components easily solvable in the water. We suggest systematic approach for measuring weights, volumes of core samples to calculate density and porosity. Measurements reveal that the resistivities of black host rock, gray host rock, pumice and chimney are 102, 39, 11, 0.1 ohm-m, respectively, when the core samples are saturated with saline water of $32,000\;{\mu}S$/cm (0.5 ohm-m) at temperature of $2.5^{\circ}C$ and these correspond to the factors of 5 for sea water, 110 for pumice and 390~1020 for host rocks with respect to the resistivity of chimney. We also confirm that resistivity of rock samples saturated with water decrease with temperature linearly over the temperature range of $20{\sim}80^{\circ}C$.

Comparison of Physical Properties obtained from Geophysical Well Log and Core Property Measurements in Gabsan Formation (갑산층 석회암지역에서의 코어물성과 검층물성 비교)

  • 김영화;김기주
    • The Journal of Engineering Geology
    • /
    • v.9 no.3
    • /
    • pp.253-265
    • /
    • 1999
  • Physical properties of Paleozoic sedimentary rocks in Gabsan formation in Jechon area were obtained by both geophysical well log methods and core property measurements, and the similarity and difference shown between the well log and core log responses were analyzed. The physical properties obtained are natural gamma, resistivity and density. From the difference in density response between the well log and core measurement, the need of correction for natural gamma effect on density log was strongly suggested. And fairly good correlation was obtained between well log and core properties, and among natural gamma, resistivity and density by applying natural gamma correction on density log. It is noted that shale in Gabsan formation reveals very high density, even higher than the density of adjacent non-porous limestone.

  • PDF

Electrical Resistivity Response Due to the Variation of Embankment Shape and Reservoir Level (제체형태와 수위에 따른 전기비저항 반응 연구)

  • Oh, Seok-Hoon
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.214-220
    • /
    • 2008
  • The distortion effect of electrical response for two-dimensional (2-D) DC resistivity method was verified in terms of 2-D inversion result of synthetic data obtained by three-dimensional (3-D) modeling, which is frequently applied to assess the safety of center core-type fill dam structure. The distortion effect is due to 2-D interpretation for 3-D structure. By the modeling analysis, we found that the water level is correctly described in the resistivity section around the middle part rather than each end side of the embankment due to the 3-D terrain effect, when the material of the embankment is assumed as horizontally uniform. And when we set the slope of outer rock fill part as uniform. the sharper the slope of the center core is, the more similar the resistivity section reflects. On the other hand, when the slope of the rock fill is steep, the resistivity section shows the water level at lower position than the real one, and the 3-D distortion effect at the end side of the embankment was enhanced.

Lithology Determination by Log Analysis from a Borehole-PABH1 in the Pungam Sedimentary Basin (풍암퇴적분지 내 시추공 PABH1에서의 물리검층에 의한 암상의 판정)

  • 김영화;장승익
    • The Journal of Engineering Geology
    • /
    • v.8 no.2
    • /
    • pp.163-173
    • /
    • 1998
  • Suite of log analysis techniques consisting of geophysical well log, geological core log, and physical core log have been made to understand the well log responses and to determine the lithology of a test borehole-PABH1 located in Pungam sedimentary basin, Sosok, Hongchon-gun, Kangwon Province. Geological core logging has been precisely made over the cores taken between 64 and 124 meters, and 11 groups of rock types were deduced. Using the core samples divided by 11 groups, geophysical property measurements consisting of resistivity, natural gamma and density were made. Each rock group in the area is shown to have its characteristic physical response from geophysical well log and geophysical core logs. The outstanding physical responses particularly shown from siltstone, coarse sandstone to conglomerate, and granitic gneiss in the area were effectively used as keybeds in correlating the geophysical well logs to the result of geological core logs.

  • PDF