• Title/Summary/Keyword: 코발트60

Search Result 91, Processing Time 0.033 seconds

Producibility of Aflatoxin by Aspergillus parasiticus in Barley and Their Radiosensitivity (Aspergillus parasiticus에 의한 보리의 Aflatoxin 생성(生成)과 감마선(線)의 영향(影響))

  • Chang, Hak-Gil;Markakis, Pericles
    • The Korean Journal of Mycology
    • /
    • v.9 no.1
    • /
    • pp.1-6
    • /
    • 1981
  • The effect of gamma irradiation on production and accumulation of aflatoxin on natural substrate (barley) by Aspergillus parasiticus NRRL 2999 has been studied in some detail. Gamma irradiation at five doses, 0, 50, 100, 200 and 400 Krad was applied to the grain either soon after moisture equilibration (3 days after inoculation) or 10 days later (13 days after inoculation). And the results were as in the followings. 1. Increase in moisture content from 17% to 25% greatly increased the aflatoxin concentration, especially at zero irradiation dose. 2. Prolongation of the incubation period prior to irradiation from 3 to 13 days resulted in greater accumulation of aflatoxin. 3. Two hundreds Krad applied 13 days after inoculation on barley stored at 25% moisture (100% RH) and $25^{\circ}C$ led to higher aflatoxin production than 100 Krad or even 50 Krad. 4. The relative proportion of the principal aflatoxins in relation to irradiation showed that aflatoxin G was elaborated at a significantly higher rate than aflatoxin B.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

Preparation of Polypropylene Fabric Adsorbent Containing Phosphoric Acid by Radiation-Induced Graft Copolymerization, and Adsorption of $Cu^{2+}$, $Pb^{2+}$ and $Co^{2+}$ (방사선 그라프트 공중합에 의한 인산기를 갖은 폴리프로필렌 부직포 흡착제의 제조 및 구리, 납, 및 코발트 이온의 흡착)

  • Park, Keun-Su;Chang, Choo-Hwan;Kim, Hak-Jin;Choi, Seong-Ho;Nho, Young Chang
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.7-12
    • /
    • 1999
  • The cation-exchange adsorbent (CEA) was prepared by radiation-induced grafting of glycidyl methacrylate (GMA) onto polypropylene (PP) fabric and its subsequently phosphonation. The adsorption characteristics of $Pb^{2+}$, $Cu^{2+}$ and $Co^{2+}$ for the CEA were discussed. In the grafting of GMA onto PP fabric, the degree of grafting (%) increased with increasing reaction time, reaction temperature, and pre-irradiation dose. The maximum grafting yield was observed around 60% GMA concentration. The content of phosphoric acid ranges from 2.5 to 3.5 mmol/g with the 85% phosphoric acid. The adsorption of $Pb^{2+}$, $Cu^{2+}$ and $Co^{2+}$ by the CEA was enhanced with increasing phosphoric acid content. The order of adsorption capacity of CEA was $Pb^{2+}$>$Co^{2+}$>$Cu^{2+}$.

  • PDF

Radiolysis of Paraffin Encapsulation Wax (파라핀 고화체의 방사선적 가수분해)

  • Kim, Chang-Lak;Lee, Myung-Chan;Park, Won-Jae;Suk, Tae-Won;Burns William G.
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • An estimate is made on the potential generation rate of H: from radiolysis of the Paraffin-wax encapsulant Proposed for the solidified liquid concentrate wasteform. The results show that the radiolytic Production of $H_2$ from paraffin-wax-encapsulated waste is dominated by the radiation energy released from $^{60}Co$. The radiolytic production of $H_2$ will proceed at an initial rate equivalent to aproximately $4.4{\times}10^2cm^3yr^1$ in 200 litre drums that are partly filled with 120 litres of encapsulated waste. The gas production rate will fall to a value of $7.2cm^3yr^1$ after 100 years. The lower flammable limit for $H_2$ in air will be reached in about 25 years and the lower explosive limit for $H_2$ in air would not be reached in 1000years. The timescale in which these safety-related limits are reached is strongly dependent on the level of filling of each waste drum. A reduction of the air space inside each drum would reduce the time required to reach the lower flammable limit.

  • PDF

Cytokinesis-blocked micronuclei in the human peripheral lymphocytes following low dose γ-rays irradiation (저선량의 감마선 피폭된 사람 말초 임파구의 미소핵을 이용한 방사선 생물학적 피폭선량 측정법 연구)

  • Kim, Tae-hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.1
    • /
    • pp.99-104
    • /
    • 2001
  • To determine if micronucleus (MN) assay could be used to predict the absorbed dose of victims after accidental radiation exposure, we carried out to assess the absorbed dose depending on the numerical changes of MN in human peripheral blood lymphocytes after $^{60}Co\;{\gamma}-rays$ exposure in the range of 0.25 to 1 Gy, respectively. The MNs were observed at very low doses, and the numerical changes according to doses. Satisfactory dose-effect calibration curve is observed after low dose irradiation of human lymphocytes in vitro. When plotting on a linear scale against radiation dose, the line of best fit was $Y=(0.02{\pm}0.0009)+(0.033{\pm}0.010)D+(0.012{\pm}0.012)D^2$. The dose-response curve for MN induction immediately after irradiation was linear-quadratic and has a significant relationship between the frequencies of MN and dose. These data show a trend towards increase of the numbers of MN with increasing dose. The number of MN in lymphocytes that were observed in the control group is $0.1610{\pm}0.0093/cell$. Accordingly, MN assay in human peripheral lymphocytes could be a useful in viva model for studying radio-protective drug sensitivity or screening test, microdosimertic indicator and radiation-induced target organ injury. Since MN assay is simple, rapid and reproducible, it will also be a biodosimetric indicator for individual dose assessment after accidental exposure.

  • PDF

Recovery of Copper from Synthetic Leaching Solution of Manganese Nodule Matte by Solvent Extraction-electrowinning Process (망간단괴 매트상 모의 침출용액으로부터 용매추출-전해채취 공정에 의한 구리의 회수)

  • Kim, Hyun-Ho;Park, Kyung-Ho;Nam, Chul-Woo;Yoon, Ho-Sung;Kim, Min-Seuk;Kim, Chul-Joo;Park, Sang-Woon
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.60-67
    • /
    • 2016
  • A scale-up test with a continuous solvent extraction and electro-winning system was carried out to separate and recover copper from a synthetic sulfuric acid solution (Cu 10.5 g/L, Co 2.0 g/L, Ni 15.0 g/L, Fe 0.2 g/L). The solution was introduced into mixer-settlers with four stages of extraction and two stages of stripping for continuous countercurrent solvent extraction to separate copper from nickel and cobalt. The loading was carried out using 40% LIX 84-I(v/v) as extractant with a phase ratio of A : O = 1 : 1. Meanwhile, the stripping was undertaken at a phase ratio of A : O = 1 : 1.5 using depleted electrolyte containing 35.0 g/L Cu and 180 g/L $H_2SO_4$ as stripping solution. The extraction and stripping efficiencies were found to be 96.7% and 91.0%, respectively. The copper composition of the stripped solution (pregnant electrolyte) was 50.0 g/L Cu with impurities of 25 ppm nickel, 5 ppm cobalt and 3 ppm iron. In the electro-winning process, copper metal of 99.833 purity was yielded with current efficiency of 98.9% and current density of $1.50A/dm^2$.

High-purity Lithium Carbonate Manufacturing Technology from the Secondary Battery Recycling Waste using D2EHPA + TBP Solvent (이차전지 폐액으로부터 D2EHPA + TBP solvent를 활용한 탄산리튬 제조기술)

  • Dipak Sen;Hee-Yul Yang;Se-Chul Hong
    • Resources Recycling
    • /
    • v.32 no.1
    • /
    • pp.21-32
    • /
    • 2023
  • Because the application of lithium has gradually increased for the production of lithium ion batteries (LIBs), more research studies about recycling using solvent extraction (SX) should focus on Li+ recovery from the waste solution obtained after the removal of the valuable metals nickel, cobalt and manganese (NCM). The raffinate obtained after the removal of NCM metal contains lithium ions and other impurities such as Na ions. In this study, we optimized a selective SX system using di-(2-ethylhexyl) phosphoric acid (D2EHPA) as the extractant and tri-n-butyl phosphate (TBP) as a modifier in kerosene for the recovery of lithium from a waste solution containing lithium and a high concentration of sodium (Li+ = 0.5 ~ 1 wt%, Na+ = 3 ~6.5 wt%). The extraction of lithium was tested in different solvent compositions and the most effective extraction occurred in the solution composed of 20% D2EHPA + 20% TBP + and 60% kerosene. In this SX system with added NaOH for saponification, more than 95% lithium was selectively extracted in four extraction steps using an organic to aqueous ratio of 5:1 and an equilibrium pH of 4 ~ 4.5. Additionally, most of the Na+ (92% by weight) remained in the raffinate. The extracted lithium is stripped using 8 wt% HCl to yield pure lithium chloride with negligible Na content. The lithium chloride is subsequently treated with high purity ammonium bicarbonate to afford lithium carbonate powder. Finally the lithium carbonate is washed with an adequate amount of water to remove trace amounts of sodium resulting in highly pure lithium carbonate powder (purity > 99.2%).

Effects of Cobalt-60 Gamma Ray Irradiation on Blood Cells and Enzyme Activity of Albino Rats (코발트-60 감마선(線) 조사(照射)가 흰쥐의 혈액성분(血液成分) 및 수종(數種) 효소(酵素)의 활성(活性)에 미치는 영향(影響))

  • Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.47-63
    • /
    • 1985
  • This paper was aimed to study the effects of Cobalt-60 gamma ray irradiation on Albino rat blood cells and the activity of enzymes were measured using blood cell auto analyzer (Cell-Dyn 900) and enzyme autoanalyzer (Gilford 3500) respectively. Cobalt-60 gamma rays those are grouped into 200R, 400R, 600R, 800R, 1,000R, 1,200R, 1,300R, 1,400R, 1,500R and 1,600R to the rats of male and female and measured the numeral varieties of blood corpuscles of the rats and the active varieties of enzyme of acid, alkaline phosphatase (ACP, ALP), lactic acid dehydrogenase (LDH), glutamic oxaloacetic transaminase (GOT) and glutamic pyruvic transaminase. (GPT) those came out after 1, 3, 5 or 7 days. The results are summarized as follows: 1. In both case of male and female, the numeral varieties of the erythrocytes, in the 200R group of irradiation showed the minimum value in the 3 days group and a tendency of increase in the 5 and 7 days groups, while the numeral varieties of the leucocytes in every groups of irradiation showed a tendency of a rapid decrease after a day. The numeral varieties of the blood platelet in both case of male and female didn't show generally any great change in a day and 3 days groups, but showed a rapid decreasing appearance after the 5 days. 2. In both case of male and female, the activities of ACP were on the decrease gradually after 3 days of the irradiation and the activities of ALP were on the decrease after 5 days. Similarly in both case of mate and female, the activities of LDH showed the decrease after 3 and 5 days, and the phenomenous of GOT showed an appearance of increase in a day, but decreased after 3 days. As for the GPT activities couldn't find any great change in the male rats in comparison with the control groups, but in the female rats a tendency of the increase in 600R, 800R, 1,000R groups after 3 days. 3. In the case of the irradiation of high quantity of ray more than 1,200R, all rats died after 4 days, and by the irradiation of 1,600R all rats died after 3 days, and it showed the sensitive response of a living body to the irradiation of high quantity.

  • PDF

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.