• Title/Summary/Keyword: 코발트 크롬 합금

Search Result 22, Processing Time 0.037 seconds

Dental Co-Cr alloys fabricated by selective laser melting: A review article (선택적 레이저 용융 방법으로 제작한 치과용 코발트 크롬 합금에 대한 문헌고찰)

  • Kang, Hyeon-Goo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.248-260
    • /
    • 2021
  • Cobalt-chromium alloys are used to fabricate various dental prostheses, and have advantages of low cost and excellent mechanical properties compared to other alloys. Recently, selective laser melting, which is an additive manufacturing method, has been used to overcome the disadvantages of the conventional fabrication method. A local rapid heating and cooling process of selective laser melting induces fine microstructures, grain refinement, and reduction of porosities of the alloys. Therefore, it can improve mechanical properties compared to the alloys fabricated by the conventional method. On the other hand, layering process and rapid heating and cooling cause accumulation of a large amount of residual stresses that can adversely affect the mechanical properties. A heat treatment for removing residual stresses through recovery and recrystallization process caused complicated changes in mechanical properties induced by phase transformation, precipitate and homogenization of the microstructures. The purpose of this review was to compare the manufacturing methods of Co-Cr alloys and to investigate the characteristics of Co-Cr alloys fabricated by selective laser melting.

Leaching of CMSX-4 Superalloy in Hydrochloric Acid Solutions (염산(鹽酸)에 의한 CMSX-4 초내열합금(超耐熱合金)의 침출(浸出))

  • Kim, Min-Seuk;Lee, Jae-Chun;Kim, Eun-Young;Yoo, Young-Soo
    • Resources Recycling
    • /
    • v.19 no.5
    • /
    • pp.25-30
    • /
    • 2010
  • Leaching of CMSX-4 superalloy was done in hydrochloric acid solutions. The leaching behaviors of main alloy components, such as Ni, Co, Cr, Al, was investigated by controlling acid concentration, temperature, leaching time and pulp density. Increasing acid concentration enhanced the leaching rate till the rate decreased over 3 M acid concentration. Raising temperature increased the leaching amount of the metal components. After the leaching for 60 minutes at $90^{\circ}C$ and 10 g/L pulp density in 4 M acid solution, 93.2% nickel, 89.9% aluminum, 80.4% cobalt, and 79.1% chromium were leached. Nickel and aluminum were preferentially leached out, while the leaching rate of cobalt and chromium were relatively high only after 60 minutes, Increasing pulp density lowered the leaching rate and especially serious on cobalt and chromium, The optimum leaching condition for CMSX-4 was obtained at $90^{\circ}C$, 120 minutes, and less than 125 g/L in 4 M hydrochloric acid solution.

Electro-deposition of Sn-Fe plating containing Fe3+ (3가 철이온을 함유한 주석도금)

  • Kim, Yu-Sang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.287-287
    • /
    • 2012
  • 주석합금도금 피막은 약한 전류가 흐르는 전자제품, 휴대전화, 자동차 공업용, 장식용으로 사용되고 있다. 현재까지 공업적으로 사용되고 있는 주석합금도금의 합금원소로서 은, 코발트, 니켈 등의 높은 가격의 금속과 납과 같이 ELV 및 RoHS 유해환경물질규제지침에 따라 수출제한을 받는 6가 크롬, 카드뮴 등이 알려져 있다.

  • PDF

Effect of Contact Pressure on the Variations in Coefficients of Friction Between Porcine Knee Joint Cartilage and Co-Cr Alloy in a Repeat Pass Sliding Motion (반복 회전운동에서 코발트 크롬 합금과 미끄럼 접촉하는 돼지 무릎 관절연골의 접촉압력이 마찰계수 변화에 미치는 영향)

  • Lee, Kwon-Yong;Kim, Hwan;Lee, Young-Ze
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.231-235
    • /
    • 2009
  • In this study, the influence of contact pressure on the variation in coefficients of friction between porcine knee joint cartilage and Co-Cr alloy in a repeat pass sliding motion was investigated. Flat-ended cartilage pin specimens(9 mm diameter, 8 mm long) were prepared from porcine(6 months old) knee joints by a drill-type punch. Friction tests were conducted by using a pin-on-disk type friction tester for an hour in PBS lubricated condition under the contact pressures of 0.5, 1 and 2 MPa with 50 mm distance per a cycle at ambient condition. As a result, coefficients of friction increased as the test duration increased for all contact pressures. The maximum coefficients of friction were 0.082, 0.06 and 0.098 for 0.5, 1, and 2 MPa, respectively. It showed that coefficients of friction of porcine knee joint cartilage against Co-Cr alloy depended on the level of contact pressure and related to squeeze film lubrication mechanism.

Evaluation of fitness of metal-ceramic crown fabricated by cobalt-chrome alloy (코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가)

  • Kim, Jae-Hong;Kim, Won-Soo;Kim, Ki-Baek
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.2
    • /
    • pp.361-368
    • /
    • 2013
  • Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${\alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${\mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${\mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.

The Effect of Titanium on the Castability of Cobalt-Chrome Alloy (코발트 크롬 합금의 주조성에 미치는 타이타늄의 효과)

  • Ryu, Su-Kyoung;Chung, Hee-Jeong;Vang, Mong-Sook;Yang, Hong-So;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose of this experiment is to evaluate the effect of titanium on the castability when the titanium is added to the Co-Cr alloy. Raw materials Cobalt, Chrome, Molybdenum, Silicon, Manganase, Carbon, Nitrogen, Titanium were weighted and prepared. $Biosil^F$ (Degudent, Germany) was the control group. To the experimental group, different weight percent of titanium was added from 1 wt% to 4 wt%. The wax pattern is $30{\times}40$ cm in size, rectangular in shape and has total of 160 grids. Centrifugal machine (Neutrodyne Easy Ti: Manfredy) was used for casting. For evaluation of the castability, the number of complete grids was counted by visual inspection and X-ray inspection. The test showed similar castability with the control group in the titanium addition of 1 wt% to 3 wt%. The titanium addition of 4 wt% showed poor result. With titanium lower than 4 wt%, the experiment metals showed proper castability with high expectation of successful clinical use.

Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy (레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향)

  • Jung, Hong-Taek;Campana, Shiela A.;Park, Jin-Hong;Shin, Joo-Hee;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (${\mu}TBS$) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. Materials and methods: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting ($6mm\;ength{\times}1mm\;width{\times}1mm\;thick$). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide ($125{\mu}m$ grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the ${\mu}TBS$ test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (${\alpha}=.05$) using SPSS software. Results: The mean ${\mu}TBS$ of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. Conclusion: The ${\mu}TBS$ of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the ${\mu}TBS$ of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.