• Title/Summary/Keyword: 코마수차

Search Result 21, Processing Time 0.02 seconds

The Effect of Myopic Degree on the Change of Higher-order Aberrations Induced by Aging (근시도가 나이에 따라 유발되는 고위수차의 변화에 미치는 영향)

  • Ryu, Nam-Yul;Park, Kyoung-Hee;Kim, So-Ra;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.353-362
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the change of higher-order aberrations induced by aging and the effect of myopic degree on the correlation between age and higher-order aberrations. Methods: The higher-order aberrations in 931 eyes aged from 20 to 60 were measured by using a LADARWave device employing Hartmann-Shack system to analyze the effect of myopic degree measured by manifest refraction test on higher-order aberrations. Results: Coma and vertical coma aberrations were significantly decreased by the increase of myopic degree while vertical astigmatic aberration was significantly increased. The correlations of age and coma, vertical coma, spherical, vertical trefoil, horizontal trefoil, vertical astigmatic, horizontal astigmatic and vertical tetrafoil aberrations depended on the myopic degree, except for horizontal coma and horizontal tetrafoil aberrations. Conclusions: It is suggested to consider the myopic degree for the refractive correction including the laser surgery based on the present result that higher-order aberrations are affected by the myopic degree.

Computation of the ERF from the OTF (OTF계산값을 이용한 ERF계산)

  • 심상현
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.140-144
    • /
    • 1993
  • A computer program for computing the edge response function(ERF) from the optical transfer function( 0TF) was developed. The ERFs of un-aberrated optical system and aberrated optical system were studied by the use of that program. We calculated the ERFs of the optical systems with a single aberration and with a combined aberration. In sagittal case, the ERE of the optical system with defocus or spherical aberration was worse than that with coma. In tagential case, the ERF of the optical system with coma was worse than that with defocusing or spherical aberraion. Both the shape and the position of ERF were varied with coma, but only the position of ERF was varied with distortion, in tangential case.

  • PDF

Curvature Linear Equation of a Coma Corrected Two-Mirror System with Finite Object Distance (유한 물체거리를 갖는 코마수차가 보정된 2 반사경계의 곡률선형방정식)

  • Hwang, Seok-Ju;Rim, Cheon-Seog;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.19-23
    • /
    • 2007
  • We derived analytically the generalized curvature linear equation useful in the initial optical design of a two-mirror system with finite object distance, including an infinite object distance from paraxial ray tracing and Seidel third order aberration theory for coma coefficient. These aberration coefficients for finite object distance were described by the curvature, the inter-mirror distance, and the effective focal length. The analytical equations were solved by using a computer with a numerical analysis method. Two useful linear relationships, determined by the generalized curvature linear equations relating the curvatures of the two mirrors, for the cancellation of each aberration were shown in the numerical solutions satisfying the nearly zero condition ($<10^{-10}$) for each aberration coefficient. These equations can be utilized easily and efficiently at the step of initial optical design of a two-mirror system with finite object distance.

Changes in Spherical Aberration and Coma Aberration after Wearing Aspheric Soft Contact Lens in Young Myopes (젊은 성인 근시안에서 비구면 소프트 콘택트렌즈 착용 후 구면수차와 코마수차의 변화)

  • Lim, Dong-Kyu;Kwon, Hyeok;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.469-482
    • /
    • 2018
  • Purpose : We investigated the change of spherical and comma aberrations after wearing aspheric soft contact lens (ASCL) in young myopes. Methods : Fifty young myopes ($23.15{\pm}1.70years$, spherical equivalent: $-2.90{\pm}1.75D$) were recruited and refractive errors were corrected using ASCL (Biotrue, Bausch+Lomb, USA). High order aberrations were measured in the 4 mm pupil size using the wavefront analyze and pupil sizes were measured with a pupillometer at the modes of scotopic condition (light off) at 3.5 m in the 100 lx illuminance condition. Results : Spherical aberrations and coma aberration of the 20s myopes were $0.026{\pm}0.031{\mu}m$ and $0.078{\pm}0.039{\mu}m$ respectively, and $0.019{\pm}0.026{\mu}m$ and $0.082{\pm}0.038{\mu}m$ after ASCL wear that spherical aberration was decreased and coma aberration was increased. However, spherical aberration was decreased in the 68% of the subject have positive spherical aberration, and increased in the 11% of the subject have negative spherical aberration. Coma aberration was increased in the 53% of the subject, did not change in the 19% of the subjects, and decreased in the 28% of the subject. Spherical aberration was not different with the refractive errors in low and moderate myopies, however, coma aberrations was higher in the higher myopes. Conclusion : In a scotopic condition without accommodation stimuli, spherical aberration is decreased after wearing ASCL, however in the subject have negative spherical aberration spherical aberration could be increased, and which is thought to be the influence of contact lens design and pupil size.

Performance Criterion of Bispectral Speckle Imaging Technique (북스펙트럼 스펙클 영상법의 성능기준)

  • 조두진
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.28-35
    • /
    • 1993
  • In the case of an imaging system affected by aberrations which are not precisely known, the effect of aberrations can be minimized and near-diffraction-limited images can be restored by introducing artificial random phase fluctuations in the exit pupil of the imaging system and using bispectral speckle imaging. In order to determine the optimum value of the correlation length for Gaussian random phase model, computer simulation is performed for 50 image frames of a point object in the presence of defocus, spherical aberration, coma, astigmatism of 1 wave, respectively. In terms of the criterion of performance, the FWHM of the point spread function, normalized peak intensity, MTF and visual inspection of the restored object are employed. The optimum value for the rms difference $\sigma$ of aberration on the exit pupil in the interval of Fried parameter ${\Upsilon}_0$ is given by 0.27-0.53 wave for spherical aberration, and 0.24-0.36 wave for defocus and astigmatism, respectively. It is found that the bispectral speckle imaging technique does not give good results in the case of coma.

  • PDF

Design and Aberration Analysis of Four-Spherical Mirror System Corrected for 4 Aberrations (4개의 수차가 보정된 유한 물체점을 갖는 4-구면 반사경계의 설계 및 수차해석)

  • 김종태;공홍진;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.127-132
    • /
    • 1991
  • We have obtained the analytic solutions of the four spherical mirror system free from the Seidel third order aberratios which are spherical aberration, coma, astigmatism, and distortion, Vignetting. Petzval field curvature, and optical properties according to the design parameters are numerically investigated and optimized. The numerical aperture of this system is 0.2 and the half field angle is $1.5^{\circ}$.

  • PDF

Correlations between Higher-order Aberrations and Myopic Degree (근시도와 고위수차와의 상관관계)

  • Ryu, Nam-Yul;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the correlation between higher-order aberration and myopic degree by the analysis of fluctuation of high-order aberration according to the change of myopic degree in certain ranges of myopia and astigmatism. Methods: The high-order aberration in a total of 992 eyes was analyzed by using a LADARWave device employing Hartmann-Shack system, and the relation between high-order aberration and myopia by the change of myopic degree through manifest refraction test. Results: In all subjects, spherical aberration and total coma aberration were significantly increased by the increase of myopic degree, however, trefoil aberration and astigmatic aberration and tetrafoil aberration were decreased. With the group of lower myopic degree, the change of coma aberration was greater by myopic degree and its change was significantly different. The change of spherical aberration by myopic degree was greatly large in the a group of -3.00 D or more and the group of -6.00 D or more where as its change was not large in the group of lower than -3.00 D. The significant decrease of coma aberration was observed only in the group of astigmatic degree of -1.00 D or less when analyzing the correlation between the higher-order aberrations and myopia in the certain groups of astigmatic degree. In the case of spherical aberration, the significant change was shown in all astigmatic groups, however, its increase was larger with the increase of myopic degree in lower degree of astigmatism. The consistent relationship in variations of horizontal and vertical coma aberration in certain myopic and astigmatic groups was neither established nor statistically significant. Conclusions: It is concluded that the correlation between the higher-order aberration and low-order aberration obtained from the results of the present study can help the understanding related to vision quality and the improvement of vision quality.

Korea Astronomy Observatory 1 m Telescope Its Opto-mechanical Characteristics and Performance (한국천문연구원 1 m 망원경 광학 기계부 설계 제작 및 성능 소개)

  • 한인우;장정균;김한철
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.210-211
    • /
    • 2000
  • 한국천문연구원에서는 1 m 망원경을 국내 기술로 설계 제작하여 현재 시험 관측을 수행하고 있다. 이 망원경은 가대는 경위도식이고 광학계는 Ritchey-Chretien 형 망원경이다. Ritchey-Chretien 형은 구면 수차와 코마 수차가 없는 광학계로서 대부분의 천문 연구 망원경이 Ritchey-Chretien 형으로 제작되고 있다. 원래의 광학계 설계는 합성초점비가 F/10, 주경 곡률 반경이 5,700 mm로 설계하였으나 주경 가공 과정에서 주경의 곡률 반경과 원뿔상수 (conic constant)가 설계치와 차이가 발생하여, 이에 맞추어 전체 시스템 설계를 변경하였다. 최종 완성된 망원경의 광학계 설계 수치는 아래 표와 같다. (중략)

  • PDF

Four Spherical Mirror Stepper Optics for Deep UV Micro-Lithography (Deep UV 마이크로 리소그라피용 Stepper를 위한 4구면 반사경계)

  • 조영민;이상수;박성찬
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.186-192
    • /
    • 1991
  • For the micro-lithography using a excimer laser beam $(\lambda\leq0.248$\mu\textrm{m})$. a mirror system consisting of four spherical surfaces with reductlon magnification 5X is designed. Initially the aplanat, flat field and the distortion free condition of the system are analytically investigated within Seidel 3rd order aberrations. And the computer-aided optimization technique has been employed for the further improved performance of the system. The final system has N.A. of 0.15 and image field diameter 3.3 mm, and has the diffraction-limited performance for KrF eximer laser beam.

  • PDF