Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample (저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.123-131
    • /
    • 2018
  • This study compared PENELOPE with measured values from low energy peak to high energy peak to reduce peak to compton ratio and continuum background spectrum using $^{60}Co$, $^{137}Cs$ and mixed volume source. In addition, the change in backscattering and compton edge efficiency was compared with that of PENELOPE through changes in the vicinity of low energy. The results from the mixed volume source are applied to the soil samples to determine how much the minimum detection limits of the soil samples are reduced in the suppression and unsuppressed mode. The compton suppression of the low energy region of $^{60}CO$ (1,173 keV) was considerable, and the Compton edge RF for the $^{137}Cs$ (661 keV) peak was 2.8. In particular, the $^{60}Co$ source emits coincidence gamma rays of 1,173.2 keV and 1,332.5 keV, so compton inhibition was reduced by approximately 21%. RF of compton edges of 1,173 keV and 1,332 keV emitted from a $^{60}Co$ source was 3.2 and 3.4, and the peak to compton edge ratio was improved to 8: 1. And Compared with Penelope, the uncertainty was well within 2%. In compton unsuppressed mode, MDA values of 661 keV, 1,173 keV and 1,332 keV were 0.535, 0.173 and 0.136 Bq/kg, respectively, but decreased in compton suppressed mode to 0.121, 0.00826 and 0.00728 Bq/kg. Thus, Compton suppressed could reduce the background radioactivity and the radioactivity contained in the detector itself.

Study of 4π Compton Suppression Spectrometer by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 4π 컴프턴 억제 분광기 연구)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.123-129
    • /
    • 2017
  • Compton suppression apparatus using the Compton scattering response, by inhibiting part of the spectrum Compton continuum Compton continuum in the area of the peak analysis of the gamma rays that enables a clearer device. In order to find out the geometry structure of high-purity germanium detector(HPGe) -NaI(TI) and to optimize the effect of movement, Monte Carlo simulation was used to grasp the behavioral characteristics of Compton suppression and compare several layout structures. And applied to the cylinder beaker used for the environmental measurement by using the efficiency according to the distance. For the low-energy source such as 81 keV, the Compton continuum is scarcely developed and the suppression effect is also insignificant because the scattering cross-section of the Compton effect is relatively low. In the spectrum for the remaining energy, it can be seen that the Compton continuum part is suppressed in a certain energy range. Compton suppression effect was not significantly different from positional shift. average reduction factor(ARF) value was about 1.08 for 81 keV and about 1.23 for 1332.4keV energy at the highest value. It can be seen that suppression over the Compton continuum region of the energy spectrum is a more appropriate arrangement. Therefore, it can be applied to various environmental sample measurement through optimized structure.