• Title/Summary/Keyword: 컴퓨터 촬영

Search Result 1,198, Processing Time 0.042 seconds

Emotion Recognition from Body Movement (신체움직임에 대한 컴퓨터비전 기반 실시간 감정인식)

  • 박한훈;박종일;우운택
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.157-160
    • /
    • 2001
  • 컴퓨터와 주변장치의 급속한 발전은 인간과 컴퓨터 사이의 인터페이스에 많은 변화를 가져왔다. 특히, 인간의 감정을 인식하는 기술은 컴퓨터를 보다 인간 친화적으로 만들기 위한 노력으로, 그 동안 꾸준히 진행되어 왔다. 본 논문에서는 한대의 카메라로 촬영한 영상으로부터 실시간으로 신체움직임이 표현하는 감정을 인식할 수 있는 방법을 제안하고, PC기반의 실시간 감정 인식 시스템을 구현한다.

  • PDF

Dynamic Computed Tomographic Characteristics of aColorectal Leiomyoma in a Dog (개에서 발생한 결장 평활근종에 대한 동적 컴퓨터 단층촬영 소견 1례)

  • Park, Noh-Won;Chung, Wook-Hun;Han, Jae-Woong;Eom, Ki-Dong
    • Journal of Veterinary Clinics
    • /
    • v.32 no.2
    • /
    • pp.200-204
    • /
    • 2015
  • A 12-year-old neutered male Shih Tzu presented with constipation and dyschezia. Abdominal radiographs showed distension of the descending colon and dorsal compression of the colon by a soft tissue mass. The mass was well-marginated with homogeneous soft tissue attenuation and showed no evidence of metastasis on computed tomography (CT). The dynamic CT showed a consistently mild contrast enhancement. The perfusion and capillary permeability were lower than those of the gluteal muscle. The tentative imaging diagnosis was a benign intrapelvic tumor, which rarely shows angiogenesis. The mass was excised, and a leiomyoma was confirmed by histopathologic examination.

Slow Sync Image Synthesis from Short Exposure Flash Smartphone Images (단노출 플래시 스마트폰 영상에서 저속 동조 영상 생성)

  • Lee, Jonghyeop;Cho, Sunghyun;Lee, Seungyong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.27 no.3
    • /
    • pp.1-11
    • /
    • 2021
  • Slow sync is a photography technique where a user takes an image with long exposure and a camera flash to enlighten the foreground and background. Unlike short exposure with flash and long exposure without flash, slow sync guarantees the bright foreground and background in the dim environment. However, taking a slow sync image with a smartphone is difficult because the smartphone camera has continuous and weak flash and can not turn on flash if the exposure time is long. This paper proposes a deep learning method that input is a short exposure flash image and output is a slow sync image. We present a deep learning network with a weight map for spatially varying enlightenment. We also propose a dataset that consists of smartphone short exposure flash images and slow sync images for supervised learning. We utilize the linearity of a RAW image to synthesize a slow sync image from short exposure flash and long exposure no-flash images. Experimental results show that our method trained with our dataset synthesizes slow sync images effectively.

Night Vision Pedestrian Detection using Contrast Enhancement Algorithm (대비 개선 기법을 이용한 야간 보행자 검출)

  • Han, Tae Young;Song, Byung Cheol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2016.06a
    • /
    • pp.222-223
    • /
    • 2016
  • 보행자 인식을 위한 컴퓨터 비전 알고리즘은 야간 상황과 같이 저조도 환경에서는 인식 성능이 떨어지고 있다. 이로 인하여 최근 저조도 환경에서 촬영된 영상으로 야간 상황에서 객체 인식 성능을 높이는 기법들이 연구되고 있다. 야간 환경은 주간 환경과는 다르게 광량이 적기 때문에 인간의 시각으로도 객체 인식에 어려움이 있고 일반적인 카메라로 촬영된 영상으로 객체 인식이 어렵다. 최근에는 NIR 카메라를 이용하여 촬영된 영상으로 야간 보행자 인식 알고리즘이 개발되고 있으나, 인식률과 객체 인식 가능 거리 및 범위가 한정적이다. 또한 기존의 야간 보행자 검출 기법들은 방대한 연산량이 필요하기 때문에 실시간 객체 인식이 불가능하다. 본 논문에서는 NIR 카메라로부터 촬영된 영상으로 preprocessing 후 ACF(Aggregated Channel Feature)를 이용하여 최근 연구되고 있는 카메라 움직임이 있는 야간 환경에서 보행자 인식 알고리즘을 PC 및 TK1 Board 환경에서 구현하고 객체 인식률을 높인다.

  • PDF

Missing tissue compensator modeling using a digital image technique in Radiation Therapy (디지털 영상을 이용한 방사선치료용 결손조직보상체 모델링)

  • Kim, Yonng-Bum;Choi, O-Hoon
    • Annual Conference of KIPS
    • /
    • 2005.05a
    • /
    • pp.907-910
    • /
    • 2005
  • 방사선치료에서 결손조직의 보호를 위해 사용되는 기존의 결손조직 보상체는 체표윤곽을 얻기위해 컴퓨터단층촬영영상이나 자기공명촬영영상등의 의료영상을 이용해 왔다. 하지만 이러한 촬영을 위해서는 고가의 비용이 소요되고 방사선치료에 따른 체표윤곽의 변화에 적절히 대응하지 못하는 등의 단점이 지적되고 있다. 따라서 본 연구에서는 사용이 간편한 디지털 카메라로 환자를 촬영한 후 얻은 2차원 이미지를 이용하여 결손조직 보상체를 제작하고 이의 유용성 평가를 위해 기하학적, 선량학적 평가를 수행하였다. 그 결과, 조직결손을 보정하고 정상조직을 보호할 수 있어 임상적용의 가능성을 확인 할 수 있었다.

  • PDF

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

Volumetric Estimation of the Prostate Gland using Computed Tomography in Normal Beagle Dogs (정상 비글견에서 컴퓨터단층촬영술을 이용한 전립선의 부피 평가)

  • Choi, Ji-Young;Choi, Soo-Young;Lee, Ki-Ja;Jeong, Woo-Chang;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2014
  • The purpose of this study was to determine and compare prostate size using ultrasound and computed tomography (CT). The prostate gland was evaluated in eight normal Beagle dogs. Length, depth, and width of the prostate gland were measured by ultrasound and volume of the prostate was obtained from the two ellipsoid formula (US1, US2). Height, length, width, area, and volume of the prostate gland were measured by CT. Ratios of prostatic height, length, and width to the sixth lumbar vertebral body length were calculated. There was no significant difference between the US1 and US2 method, and between US2 and CT method, respectively. The prostatic volume calculated by US1 method was significantly lower than those with CT (p=0.029). The Upper limits of ratios of prostate length, height, and width to the length of the sixth lumbar vertebra were 1.3, 1.1, and 1.7, respectively. Among these prostate dimensions, prostate length and height could be a useful index in estimating prostate size regardless of body weight.

Assessment of Allograft Function in Dog Single Lung Transplantation on CT (한국산 잡견에서 컴퓨터단층촬영을 이용한 이식폐의 기능평가)

  • 박기성;박창권
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1055-1061
    • /
    • 1997
  • In the field of the experimental lung transplantation, we analyzed the CT findings of acute rejection, infection in the left single allotransplanted lung of adult mongrel dogs, and the CT findings were compared with the histological findings obtained by the lung biopsy Twenty two adult mongrel dogs were divided into two groups(Donor and recipient group). Donor lungs were flushed with LPDG(low pota,ilium dextral glucose) solution(n=4) or modified Euro-collins solution(n=7) and preserved over 20 hours with $10^{\circ}C(1$ case preservation for 4hours). After left single lung transplantation, the chest X-ray and sequential computed tomogram were performed with concomitant hemodynamic study and arterial blood gas analysis on immediate postoperative period, postoperative 3rd day and postoperative 7th day. Two of eleven transplanted lungs had acute rejection which was represented as moderate infiltration at immediate or 1st postoperative d y but became extensive infiltration at postoperative 3rd day on CT. There were showed one case of bronchopleural fistula, six cases of pneumonia and two cases of pulmonary infarction. In one rejection cases, the opacity of transplanted lung was improved by injection of methylprednisolone 500mg daily during 3 days. We concluded that CT was a useful noninvasive evaluation parameter after lung transplantation and the serial CT scan enabled early detection of acute rejection.

  • PDF

The development of photo navigation app uses gps (사진의 GPS를 활용한 네비게이션 앱 개발)

  • Jang, Eun-Gyeom;Seo, Eun-Bok;Choi, Dong-Jun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.203-204
    • /
    • 2016
  • 본 프로젝트는 Tmap을 사용해서 사진의 GPS 정보를 활용한 네비게이션 App이다. 프로젝트의 핵심 기능 및 환경은 GPS가 탑재된 카메라 또는 스마트폰의 GPS를 활용한 사진 촬영의 경우, 사진에 포함된 경/위도 위치 값을 활용한 네비게이션 기능이다. 인터넷 및 디지털 사진의 경우 멋진 풍경이나 맛집, 행선지 등의 사진을 보고 장소가 어디인지? 또는 가보고 싶은 장소가 있다. 이러한 사진의 촬영 장소는 GPS 정보를 포함하는 사진의 경우, 정적인 위치가 지도상에 표시만 된다. 이렇게 정적인 지도의 위치 값을 네비게이션 기능을 활용하여 동적으로 쉽게 사진 속 장소를 쉽게 찾아 갈 수 있도록 네비게이션 기능을 제공한다. 또한 약속장소를 잘 못 찾을 때 현재의 네비게이션 주소를 알면 상대가 기존 네비게이션을 활용하여 쉽게 찾을 수 있다. 그러나 주소나 상점 등위치 정보를 모를 때 상대에게 약속 장소의 위치를 정확하게 전달하는 것은 어렵다. 이러한 문제는 현재 위치를 사진을 찍어 전송하면 그 사진에 포함된 경/위도 위치 값을 활용한 길 안내와 실제 촬영한 이미지를 함께 보면서 약속 장소를 찾아가는데 유용하게 활용될 수 있다.

  • PDF