• Title/Summary/Keyword: 컴퓨터 촬영

Search Result 1,195, Processing Time 0.037 seconds

Lower Extremity Edema in Terminal Cancer Patients (말기 암 환자에서의 하지 부종)

  • Shim, Byoung-Yong;Hong, Seok-In;Park, Ji-Chan;Hong, Sug-Hui;Choi, Gang-Heun;Cho, Hong-Joo;Kim, Seon-Young;Han, Sun-Ae;Lee, Ok-Kyung;Kim, Hoon-Kyo
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.2
    • /
    • pp.152-155
    • /
    • 2005
  • Purpose: The lower extremity edema (LEE) is a common distressful symptom in advanced cancer patients and is hard to manage. We analyze the characteristics of LEE in patients with advanced cancer to provide the basic information of causes and adequate management. Methods: Physical examination, assessment of the location and severity of edema, blood chemistry (albumin, creatinine), Doppler Sono for patients with suspecting deep vein thrombosis (DVT), and abdomen CT scan for patient with suspecting lymph edema were performed. Severity of edema was classified according to NCI lymph edema scaling and improvement was defined as lowering at least 1 grade of edema after management. Results: Among 154 patient who had been admitted to Hospice Ward from Mar 2003 to Jan 2004, 33 had LEE, and 6 had both upper extremity edema and LEE except generalized edema. Their underlying cancers were stomach (7), lung (6), biliary tract (5), liver (5), colorectal (5), pancreas (2), and others (9). There were 12 patient with grade I, 20 patients with grade II, and 7 patients with grade III edema. The causes were hypoalbuminemia (11), lymph edema (10), DVT (7), obstruction of inferior vena cava (IVC) or portal vein (6), and dependent edema (5). The common managements were including leg elevation and diuretics. Elastic stocking was applied for patients with DVT and leg massage and pneumatic compression was used for lymph edema. The 2/3 patients were improved after management. Conclusion: The incidence of LEE in terminal cancer pts was high (25.3%) and their causes were variable including lymph edema, DVT, hypoalbuminemia and dependent edema. Active noninvasive management according to causes could result in good palliation.

  • PDF

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

Stress Patterns in the Reconstructed Double Bundles of the Anterior Cruciate Ligament in Response to an Anterior Tibial Load and Rotatory Load: an Analysis using a 3-Dimensional Finite Element Model (삼차원 유한 요소 모델을 이용한 전방십자인대 이중다발 재건술 후 전방 전위 및 회전 부하에 따른 이식건 응력 양상 분석)

  • Seo, Young-Jin;Song, Si Young;Ahn, Jung Tae;Kim, Yoon-Sang;Ko, Jun Ho;Jang, Seong-Wook;Yoo, Yon-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.160-166
    • /
    • 2012
  • Purpose: The aim of this study was to determine the patterns of the stress distribution within the reconstructed anterior cruciate ligament (ACL) double bundles in response to an anterior tibial load and rotatory load at $45^{\circ}$ flexed knee model by use of a 3-dimensional finite element analysis (FEM). Materials and Methods: The $0^{\circ}$ and $45^{\circ}$ flexed 3-D knee model were reconstructed based on the high resolution computed tomography (CT) images from the right knee of a healthy male subject. To simulate double bundle ACL reconstruction, in $0^{\circ}$ analytic model, four 7 mm diameter tunnels were created at the center of each anteromedial (AM) and posterolateral (PL) footprints on the femur and tibia. The grafts were inserted into the corresponding bone tunnels and then reconstructed knee model was flexed to $45^{\circ}$. As a next step, the 5 mm anterior tibial load and internal rotational load of $10^{\circ}$ were applied on the final Computer aided design (CAD) model. And then stress patterns of each bundle were assessed using a finite element analysis. Results: In response to the 5 mm of anterior tibial load, the AM bundle showed increased stresses around the tibial and femoral attachment sites; especially in the anterior aspect of the bundle. In the PL bundle, the highest stress concentration was also noticed on the anterior aspect of the bundle. Under $10^{\circ}$ internal rotational load, the stress concentration was predominant around the anterior aspect of the tibial attachment site within the AM bundle. The PL bundle also showed highest stress concentration on the anterior aspect of the bundle. Conclusion: Although the stress patterns were not identical among the AM and PL bundle, there were common trends in the stress distribution. The stress concentration was predominant on the anterior aspect of both bundles in response to the anterior tibial load and rotatory load.

  • PDF

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Analysis of disease mechanism of subacute necrotizing lymphadenitis in children (소아 아급성 괴사성 림프절염의 임상적, 방사선학적, 면역조직화학적 소견)

  • Kim, Hyun Jung;Yeom, Jung Suk;Park, Ji Suk;Park, Eun Sil;Seo, Ji Hyun;Lim, Jae Young;Park, Chan Hoo;Woo, Hyang Ok;Cho, Jae Min;Lee, Jeong Hee;Youn, Hee Shang
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1198-1204
    • /
    • 2008
  • Purpose : The cause of subacute necrotizing lymphadenitis, a rare disease in children, has not been completely clarified. This study was aimed to investigate the disease mechanism by examining clinical, radiologic, and immunohistochemical findings in children diagnosed with subacute necrotizing lymphadenitis after an excisional biopsy. Methods : We examined 19 lymph node tissue specimens from 17 children diagnosed with subacute necrotizing lymphadenitis at Gyeongsang National University Hospital from March, 1998 to July, 2006. A retrospective survey of the medical records was performed. CT findings were analyzed. Immunohistochemical staining was done on tissues obtained by excisional biopsy from all patients. Results : The patient's age ranged from 5 to 19 years (average age :11.8 years). The main symptoms included a neck mass (17/19), pain in the mass (6/17), and fever (12/19). The palpable lymph nodes were mostly cervical in location; the maximum diameter, which was measured radiologically, was less than 3 cm in all 10 cases. The masses were pathologically divided into proliferative, necrotic, and xanthomatous types. With immunohistochemical staining the masses were divided into lesion (L), perilesion (PL), and necrosis (N). The CD8 staining was stronger than the CD4 staining for all regions in three types. The CD4 staining intensity was mainly increased in the perilesion, and CD8 was mainly increased in the lesion. Conclusion : We compared the radiologic findings, clinical symptoms, and pathology to help understand the cause of disease in patients with subacute necrotizing lymphadenitis.

The Effect of Green Coffee Bean Extract Supplementation on Body Fat Reduction in Overweight/Obese Women (과체중 여성에서 생커피두 엑기스의 섭취가 체지방 개선에 미치는 영향)

  • Park, Ju-Yeon;Kim, Ji-Young;Lee, Sung-Pyo;Lee, Jong-Ho
    • Journal of Nutrition and Health
    • /
    • v.43 no.4
    • /
    • pp.374-381
    • /
    • 2010
  • This study was performed to examine the diet effect of green coffee bean extract on body fat reduction. Overweight/obese women (body mass index > $23\;kg/m^2$ or body fat > 27%) who were not diagnosed any type of disease were included in this study and subjects were randomly assigned to green coffee bean extract group (n = 23) or placebo group (n = 20). We measured anthropometric parameters, abdominal fat distribution by computed tomography and blood components before and after the 8-weeks intervention period. After supplementation, green coffee bean extract group showed a significant reduction of body weight (p < 0.01), body fat percent (p < 0.01), total fat area at L1 vertebra (-4.8%, p < 0.05) and visceral fat area at L4 vertebra was(-4.7%, p < 0.05). In addition, total fat area and visceral fat area at L1 vertebra decreased significantly in green coffee bean extract group compared with placebo group (p < 0.05, p < 0.05 respectively). The result of present study demonstrated that the supplementation of green coffee bean extract for 8 weeks can give beneficial effects on body fat reduction and visceral fat accumulation.

High-resolution computed tomography findings of lung parenchyme changes in very low birth weight infants treated with oxygen (산소 치료를 받은 극소저출생 체중아에서 폐 실질변화에 관한 고해상컴퓨터 단층촬영술 소견에 관한 연구)

  • Jin, Young Man;Chung, David Chanwook;Chang, Young Pyo;Lee, Yung Suk;Lee, En Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.3
    • /
    • pp.255-261
    • /
    • 2007
  • Purpose : The objective of this study is to observe high-resolution computed tomography (HRCT) findings of lung parenchyme in very low birth weight (VLBW) infants between the corrected age of 38-42 weeks who were treated with oxygen after birth, and to compare them to the clinical severity of bronchopulmonary dysplasia (BPD). Methods : The lungs of fourty-four VLBW infants with gestational ages of less than 32 weeks and birth weights of less than 1,500 g who were treated with oxygen after birth were examined using HRCT taken when the corrected age was between 38-42 weeks. Common findings among the infants and the frequency of their occurrences were noted. Total CT scores obtained by the summation of air trapping and actelectasis scores and the ratio of bronchus-to-pulmonary artery diameter were used to quantitatively evaluate HRCT findings and correlate them with the clinical severity of BPD as defined by Jobe-Bancalari diagnostic criteria. Results : 1) The most common findings in HRCT images of the lungs were air trapping (56%), atelectasis (70.5%), linear opacity (77%), and distortion of the bronchopulmonary bundle (65.9%). These findings were more commonly observed in infants with BPD in a mixed pattern than those without (P<0.05). However, abnormal findings were also found in HRCT images of some infants without BPD. In infants with BPD, air trapping, atelectasis and total CT scores were higher than those without BPD. Also infants with BPD had a lower bronchus-to-pulmonary artery diameter than those without BPD (P<0.05). 2) The total CT scores (r=0.799, P<0.0001) and the ratio of bronchus-to-pulmonary artery diameter (r=0.576, P<0.0001) showed a linear correlation with the clinical severity of BPD. Conclusion : HRCT findings in VLBW infants between the corrected age of 38-42 weeks who had been treated with oxygen after birth are useful in revealing pathologic changes in the lung parenchyme and show a good correlation with the clinical severity of BPD.

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

Comparison of Stereotactic Radiosurgery and Whole Brain Radiotherapy in Patients with Four or More Brain Metastases (4개 이상의 다발성 전이성 뇌종양의 정위적 방사선수술과 전뇌 방사선조사의 비교)

  • Kim, Cheol-Jin;Baek, Mi-Young;Park, Sung-Kwang;Ahn, Ki-Jung;Cho, Heung-Lae
    • Radiation Oncology Journal
    • /
    • v.27 no.3
    • /
    • pp.163-168
    • /
    • 2009
  • Purpose: This study was a retrospective evaluation of the efficacy of stereotactic radiosurgery (SRS) in patients with >4 metastases to the brain. Materials and Methods: Between January 2004 and December 2006, 68 patients with $\geq$4 multiple brain metastases were included and reviewed retrospectively. Twenty-nine patients received SRS and 39 patients received whole brain radiotherapy (WBRT). Patients with small cell lung cancers and melanomas were excluded. The primary lesions were non-small cell lung cancer (69.0%) and breast cancer (13.8%) in the SRS group and non-small cell lung cancer (64.1%), breast cancer (15.4%), colorectal cancer (12.8%), esophageal cancer (5.1%) in the WBRT group. SRS involved gamma-knife radiosurgery and delivered 10~20 Gy (median, 16 Gy) in a single fraction with a 50% marginal dose. WBRT was delivered daily in 3 Gy fractions, for a total of 30 Gy. After completion of treatment, a follow-up brain MRI or a contrast-enhanced brain CT was reviewed. The overall survival and intracranial progression-free survival were compared in each group. Results: The median follow-up period was 5 months (range, 2~19 months) in the SRS group and 6 months (range, 4~23 months) in the WBRT group. The mean number of metastatic lesions in the SRS and WBRT groups was 6 and 5, respectively. The intracranial progression-free survival and overall survival in the SRS group was 5.1 and 5.6 months, respectively, in comparison to 6.1 and 7.2 months, respectively, in the WBRT group. Conclusion: SRS was less effective than WBRT in the treatment of patients with >4 metastases to the brain.

Bladder And Rectum Dose Define 3D Treatment Planning for Cervix Cancer Brachtherapy Comparison of Dose-Volume Histograms for Organ Contour and Organ Wall Contour (자궁경부암의 고선량률 근접치료시 장기묘사 방법에 따른 직장과 방광의 선량비교 분석)

  • Kim, Jong-Won;Kim, Dae-Hyun;Choi, Joon-Yong;Won, Yeong-Jin
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.327-333
    • /
    • 2012
  • Purpose: To analyze the correlation between dose volume histograms(DVH) based on organ outer wall contour and organ wall delineation for bladder and rectum, and to compare the doses to these organs with the absorbed doses at the bladder and rectum. Material and methods: Individual CT based brachytherapy treatment planning was performed in 13 patients with cervical cancer as part of a prospective comparative trial. The external contours and the organ walls were delineated for the bladder and rectum in order to compute the corresponding dose volume histograms. The minimum dose in 0.1 $cm^3$, 1 $cm^3$, 2 $cm^3$, 5 $cm^3$, 10 $cm^3$ volumes receiving the highest dose were compared with the absorbed dose at the rectum and bladder reference point. Results: The bladder and rectal doses derived from organ outer wall contour and computed for volumes of 2 $cm^3$, provided a good estimate for the doses computed for the organ wall contour only. This correspondence was no longer true when large volumes were considered. Conclusion: For clinical applications, when volumes smaller than 5 $cm^2$ are considered, the dose-volume histograms computed from external organ contours for the bladder and rectum can be used instead of dose -volume histograms computed for the organ walls only. External organ contours are indeed easier to obtain. The dose at the ICRU rectum reference point provides a good estimate of the rectal dose computed for volumes smaller than 2 $cm^2$ only for a midline position of the rectum. The ICRU bladder reference point provides a good estimate of the dose computed for the bladder wall only in cases of appropriate balloon position.