• Title/Summary/Keyword: 컴퓨터 방사선

Search Result 430, Processing Time 0.042 seconds

Comparative Analysis of Patterns of Care Study of Radiotherapy for Esophageal Cancer among Three Countries: South Korea, Japan and the United States (한국, 미국, 일본의 식도암 방사선 치료에 대한 PCS($1998{\sim}1999$) 결과의 비교 분석)

  • Hur, Won-Joo;Choi, Young-Min;Kim, Jeung-Kee;Lee, Hyung-Sik;Choi, Seok-Reyol;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.83-90
    • /
    • 2008
  • Purpose: For the first time, a nationwide survey of the Patterns of Care Study(PCS) for the various radiotherapy treatments of esophageal cancer was carried out in South Korea. In order to observe the different parameters, as well as offer a solid cooperative system, we compared the Korean results with those observed in the United States(US) and Japan. Materials and Methods: Two hundreds forty-six esophageal cancer patients from 21 institutions were enrolled in the South Korean study. The patients received radiation theraphy(RT) from 1998 to 1999. In order to compare these results with those from the United States, a published study by Suntharalingam, which included 414 patients[treated by Radiotherapy(RT)] from 59 institutions between 1996 and 1999 was chosen. In order to compare the South Korean with the Japanese data, we choose two different studies. The results published by Gomi were selected as the surgery group, in which 220 esophageal cancer patients were analyzed from 76 facilities. The patients underwent surgery and received RT with or without chemotherapy between 1998 and 2001. The non-surgery group originated from a study by Murakami, in which 385 patients were treated either by RT alone or RT with chemotherapy, but no surgery, between 1999 and 2001. Results: The median age of enrolled patients was highest in the Japanese non-surgery group(71 years old). The gender ratio was approximately 9:1(male:female) in both the Korean and Japanese studies, whereas females made up 23.1% of the study population in the US study. Adenocarcinoma outnumbered squamous cell carcinoma in the US study, whereas squamous cell carcinoma was more prevalent both the Korean and Japanese studies(Korea 96.3%, Japan 98%). An esophagogram, endoscopy, and chest CT scan were the main modalities of diagnostic evaluation used in all three countries. The US and Japan used the abdominal CT scan more frequently than the abdominal ultrasonography. Radiotherapy alone treatment was most rarely used in the US study(9.5%), compared to the Korean(23.2%) and Japanese(39%) studies. The combination of the three modalities(Surgery+RT+Chemotherapy) was performed least often in Korea(11.8%) compared to the Japanese(49.5%) and US(32.8%) studies. Chemotherapy(89%) and chemotherapy with concurrent chemoradiotherapy(97%) was most frequently used in the US study. Fluorouracil(5-FU) and Cisplatin were the most preferred drug treatments used in all three countries. The median radiation dose was 50.4 Gy in the US study, as compared to 55.8 Gy in the Korean study regardless of whether an operation was performed. However, in Japan, different median doses were delivered for the surgery(48 Gy) and non-surgery groups(60 Gy). Conclusion: Although some aspects of the evaluation of esophageal cancer and its various treatment modalities were heterogeneous among the three countries surveyed, we found no remarkable differences in the RT dose or technique, which includes the number of portals and energy beams.

Multiple Daily Fractionated RT for Malignant Glioma (악성 성상세포종과 다형성 교아종 치료에 있어서 다분할 방사선 치료와 단순분할 방사선치료에 대한 성적비교)

  • Yang Kang Mo;Chang Hye Sook;Ahn Seoung Do;Choi Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.151-158
    • /
    • 1994
  • Since Jan. 1992, authors have conducted a pilot study to treat malignant glioma with multiple daily fractionated(MDF) radiation therapy and this paper presents the outcome compared MDF to conventional factionated(CF) radiation therapy Between Sep. 1989 and Jan. 1993, forty three patients with high grade glioma of brain except brain stem glioma were treated: nineteen patients were treated with CF radiation therapy and 24 patients were treated with MDF radiation therapy. In CF radiation therapy, total dose was 6300cGy/35fx in 7 weeks, which 5040cGy was delivered to the initial target volume and 1260cGy to reduced target volume. And in MDF radiation therapy, total dose was 6400cGy/40fx in 4 weeks, which 3200cGy was delivered to the initial target volume as 160cGy 2 times daily 6hr apart. All patients had histologically confirmed anaplastic astrocytoma(AA) of glioblastoma multiforme (GBM) with stereotactic biopsy or craniotomy for subtotal or gross tumor resection. The range of follow-up was 7 months to 4 years with a median follow-up of 9 months. The Median survival from surgery was 9 months for all patients. The median survival was 9 months and 10 months for MDF group and CF group and 10 months and 9.5 months for glioblastoma multiforme and anaplastic astrocytoma, respectively. In 36 patients with follow-up CT scan or MRI scan, disease status was evaluated according to treatment groups, Four patients(GBM:3, AA:1) of 21 patients in MDF group, were alive with no evidence of disease, while none of patient was alive with no evidence of disease in CF group. The progression of disease had occurred in 20 patients, 11 patients and 9 patients in MDF group and CF group, respectively All of these patients showed in-field progression of disease, Four of 11 patients($27\%$) in MDF group showed the new leasion outside of the treatment field, while 5 of 9 patients($56\%$) in CF group. In our study the prognosis was not influenced by age, KPS, grade, extent of surgery and different fractional scheduled radiation therapy. Authors concluded that MDF regimen was well tolerated and shortened the treatment period from 7 weeks to 4 weeks without compromising results. We believe that further follow-up is needed to assess the role of MDF.

  • PDF

Response Evaluation after Stereotactic Ablative Radiotherapy for Lung Cancer (초기 폐암의 정위방사선치료후 반응평가 분석)

  • Choi, Ji Hoon
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.229-233
    • /
    • 2015
  • We retrospectively reviewed lung cancer patients who were treated with stereotactic ablative radiotherapy (SABR). We investigated the value of response evaluation after treatment by measuring the volume change of tumors on serial chest computed tomography (CT) examinations. The study included 11 consecutive patients with early-stage (T1-T2aN0M0) non-small cell lung cancer (NSCLC) who were treated with SABR. The median dose of SABR was 6,000 cGy (range 5,000~6,400) in five fractions. Sequential follow-up was performed with chest CT scans. Median follow-up time was 28 months. Radiologic measurement was performed on 51 CT scans with a median of 3 CT scans per patient. The median time to partial response ($T_{PR}$) was 3 months and median time to complete remission ($T_{CR}$) was 5 months. Overall response rate was 90.9% (10/11). Five patients had complete remission, five had partial response, and one patient developed progressive disease without response. On follow-up, three patients (27.2%) developed progressive disease after treatment. We evaluated the the response after SABR. Our data also showed the timing of response after SABR.

Ghosting Artifacts in Digital Radiography (디지털 방사선영상에서 고스팅 아티팩트)

  • Jung, Wonhee;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.377-382
    • /
    • 2014
  • Because of using computer system in the field of medical radiology, many artifacts which can not be seen in film/screen system are being created, especially ghosting artifacts. This artifacts could be yielded by taking advantage of a flat panel Thin-Film Transistor array detector. Ghosting artifacts can be rarely seen in clinical practice when an image that has a high-contrast object within a region of high exposure is quickly followed by another image that puts the high-contrast ghosting image in an area of lower radiation exposure. In this experiment, the ghosting artifacts were minimized for approximately 3 minutes with the unaided eye and almost disappeared for 6 minutes quantitatively between exposures. Moreover, the artifacts were influenced by more tube voltage than current and those depended not upon the number of readout cycles, but upon time.

A Study on Characteristics of A Diode Radiation Sensor for Portal Image of Therapy Radiation (치료방사선 Portal Image를 위한 다이오드 방사선 센서의 특성에 관한 연구)

  • Lee, Dong-Hun;Kwon, Jang-Woo;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.11-20
    • /
    • 1996
  • In this paper, the characteristics of therapy radiation diode sensors have been studied by using therapy radiation from the MM22 microtron accelerator. The linearity, reproducibility and error ratio were measured for feasibility as a radiation detector. Energy dependence, sensitivity change after a amount of irradiation and output value according to a number of diodes were also measured for same purpose. We have formed pulse shaping of diode signal with nuclear instruments for portal image reconstruction. The percent depth dose ratio according to field size and depth was compared with that of the detector of a ion chamber. Using thirteen silicon diodes, we can directly read diode outputs on a computer monitor after A/D conversion with 16 channels analog to digital conversion board with 12 bit resolution. The possibility for portal image with diodes has been suggested from output comparison between output value with a human phantom and that without a human phantom.

  • PDF

Volumetric Bone Mineral Density Measurement: for Surgery Specific Bone Volumes (체적골밀도 측정법 동향: 수술부위 골밀도 분석)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.53-59
    • /
    • 2022
  • DEXA, as the standard areal bone mineral density (aBMD) measurement method, often shows an insuficient correlation between aBMDs of the measured bones and referring bones and is inaccurate due to the mass effect. In contrast, quantitative computer tomography (QCT), as a volumetric BMD (vBMD) measurement method, is being advanced so that it uses less radiation before, owing to improved CT device and computer imaging technology. Because dual-energy CTs can modulate the image signals showing tumor or specific chemicals as well as the ability to measure vBMD, they are expanding their application. For pre-checking vBMD of surgeon-specific bone volume at implantation candidate sites, a finite element creation-based local vBMD measurement technique was developed. The local vBMD measurement function for surgeon-specific shape volumes will be added to clinical imaging systems.

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.

Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging (방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.207-215
    • /
    • 1998
  • There have been many radiation measurement methods so far among which film dosimetry, TLD, and ion chamber are the most frequently used methods. But this study describes a new radiation measurement method which uses polymer gel and magnetic resonance imaging(MRI). The objective of this study is to fabricate a polymer gel sensitive to radiation and to generate a dose to MRI contrast relationship, and to apply this results to the radiation measurement for the brachytherapy. To do this, 12 cm diameter cylindrical gel phantom was made, and the phantom was irradiated using the 30 mm diameter circular collimator which was used for radiosurgery. And this irradiated phantom was scanned with MRI. To find out the relationship between the radiation dose and the transversal relaxation time, an image processing software(IDL) was used. From this study it is found out that the radiation dose showed linear relationship to the transversal relaxation time of the gel up to 17 Gy($R^2$=0.993) and they had a different relationship above 17 Gy. The dose distributions were calculated using these results for the Ir-192 sources, one for the HDR afterloading system and the other for a 2 mCi seed source. And these calculated dose distributions were compared to the ones from the treatment planning computers. From this study the dose to the irradiated gel's transversal relaxation time relationship was examined, and this result was tried for the measurement of the brachytherapy.

  • PDF

Development of Film Verification as the QA of IMRT for Advanced Hepatoma Patients (간암 환자의 세기조절 방사선치료에서 임상적응 가능한 QA 기법의 개발)

  • Kim Myung-Se
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.40-46
    • /
    • 2006
  • Hepatoma is one of 3 most common malignancies in Korea, the survival rate is not improved since last decades because of delayed diagnosis and limited treatment conditions. Radiation was one of treatment options but the impact on the survival is not remarkable. High dose exposure to target area was suggested for improved effect but low tolerance dose of normal liver tissue is the main limited factor. IMRT is the advanced form of 3DCRT, for focusing high dose on target with minimal dose to surrounding normal tissues. Motion of the tumor by respiration, cardiac pulsation and peristalsis is the main treatment harrier of IMRT for treatment of hepatoma patients. Development of QA technique for acceptable geometrical uncertainties and dose error on target volume is essential for IMRT in clinical treatment but proper QA technique is not yet developed. This study compared the verification film dosimetry with measured dose in phantom and calculated dose in planning computer on exactly same conditions of patient treatments. Within 3% dose differences between 3 groups were confirmed. We suggest that our verification QA technique is easy, economic, iterative and acceptable in clinical application for advanced hepatoma patients.

  • PDF