• Title/Summary/Keyword: 컴퓨터 모의 실험

Search Result 1,320, Processing Time 0.029 seconds

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Measuring a Range of Information Dissemination in a Traffic Information System Based on a Vehicular ad hoc Network (Vehicular ad hoc network 기반 교통 정보 시스템에서 차량간 통신에 의한 정보 전달 범위 측정)

  • Kim, Hyoung-Soo;Shin, Min-Ho;Nam, Beom-Seok;Lovell, David J.
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.6
    • /
    • pp.12-20
    • /
    • 2008
  • Recent wireless communication technologies are envisioned as an innovative alternative to solve transportation problems. On ad hoc networks, as a wireless communication technology, nodes can communicate data without any infrastructure. In particular, vehicular ad hoc networks (VANETs), a specific ad hoc network applied to vehicles, enable vehicles equipped with a communication device to form decentralized traffic information systems in which vehicles share traffic information they experienced. This study investigated traffic information dissemination in a VANET-based traffic information system. For this study, an integrated transportation and communications simulation framework was developed, and experiments were conducted with real highway networks and traffic demands. The results showed that it took 3 minutes in the low traffic density situations (10 vehicle/lane.km) and 43 seconds in the high traffic density condition (40 vehicle/lane.km) to deliver traffic information of 5km away with 10% market penetration rate. In uncongested traffic conditions, information seems to be disseminated via equipped vehicles in the opposite direction. In congested traffic conditions, the sufficient availability of equipped vehicles traveling in the same direction reduces the chance to use vehicles in the opposing direction even though it is still possible.

  • PDF

Magnetic Resonance Imaging of Lumen Wall using Quadrature-typed Inside-out Receiver Coil (회전자계 역수신 코일을 이용한 관벽의 자기공명 영상)

  • 문치웅;조종운
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.385-392
    • /
    • 2001
  • This study Proposes a quadrature-typed inside-out receiver coil to obtain magnetic resonance(MR) images of lumen wall. This means that the coil should receive the signals from out-side of receiver coil. This coil has wide and uniform sensitive region to compare with previous coils such as anti-solenoid coil, octal-pole coil and so on. These coils have the disadvantages that sensitive region is narrow and inhomogenous. The proposed coil is consist of two saddle coils of which directions are orthogonal to one another. The sensitivity maps of octal-Pole coil single-saddle coil and quadrature-typed inside-out coil were obtained by computer simulation. And phantom images for each coil were obtained to evaluate the performances of the coil using both 1.5T superconducting and 0.3 Permanent magnet MRI system. The uniformity of quadrature coil's sensitivity map was superior to that of octal-polel coil. Experimentally measured SNR of quadrature coil is also 36% higher than that of single-saddle coil This study shows the possibility of quadrature-typed inside-out receiver coil for the MR lumen wall images.

  • PDF

Estimation of Medical Ultrasound Attenuation using Adaptive Bandpass Filters (적응 대역필터를 이용한 의료 초음파 감쇠 예측)

  • Heo, Seo-Weon;Yi, Joon-Hwan;Kim, Hyung-Suk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.43-51
    • /
    • 2010
  • Attenuation coefficients of medical ultrasound not only reflect the pathological information of tissues scanned but also provide the quantitative information to compensate the decay of backscattered signals for other medical ultrasound parameters. Based on the frequency-selective attenuation property of human tissues, attenuation estimation methods in spectral domain have difficulties for real-time implementation due to the complexicity while estimation methods in time domain do not achieve the compensation for the diffraction effect effectively. In this paper, we propose the modified VSA method, which compensates the diffraction with reference phantom in time domain, using adaptive bandpass filters with decreasing center frequencies along depths. The adaptive bandpass filtering technique minimizes the distortion of relative echogenicity of wideband transmit pulses and maximizes the signal-to-noise ratio due to the random scattering, especially at deeper depths. Since the filtering center frequencies change according to the accumulated attenuation, the proposed algorithm improves estimation accuracy and precision comparing to the fixed filtering method. Computer simulation and experimental results using tissue-mimicking phantoms demonstrate that the distortion of relative echogenicity is decreased at deeper depths, and the accuracy of attenuation estimation is improved by 5.1% and the standard deviation is decreased by 46.9% for the entire scan depth.

Development of the Real-Time Multiplex Channel Media Player to Heighten the Dramatic Effect of an Advertisement (광고 효과 증대를 위한 실시간 다중 채널 미디어 재생기의 개발)

  • Kim, Sung-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.50-55
    • /
    • 2011
  • This paper describes methodology which enables user in order to play multiplex channel media at realtime to augment a various advertisement effect efficiently. This method implemented from the computer environment where DirectX SDK, DirectShow and MS Visual Studio 2008 etc. are established. This media player have or hide the menu interface for reads the media. The experimental data which are used in the media player is mostly video. We added the area where has the function of Banner Ticker and GIF Animation in the media player in order augmenting an advertisement effect. All medias come to separate with video and audio by Splitter. Then that respectively execute Decoder and Render. Also the media player are possible video mixing using an alpha channel. This paper used VMR-9 of DirectShow for this. The player which sees to use multiplex channel, to remake the various medias simultaneously. Therefore, this player which sees advertisement effect of the form which is various positively in the users, has the advantage which is the possibility to recognize. This paper use tried the media player using experimental data and compare the existing media player and the media player which proposes from functional differences for an advertisement effect.

A Performance Improvement Scheme for a Wireless Internet Proxy Server Cluster (무선 인터넷 프록시 서버 클러스터 성능 개선)

  • Kwak, Hu-Keun;Chung, Kyu-Sik
    • Journal of KIISE:Information Networking
    • /
    • v.32 no.3
    • /
    • pp.415-426
    • /
    • 2005
  • Wireless internet, which becomes a hot social issue, has limitations due to the following characteristics, as different from wired internet. It has low bandwidth, frequent disconnection, low computing power, and small screen in user terminal. Also, it has technical issues to Improve in terms of user mobility, network protocol, security, and etc. Wireless internet server should be scalable to handle a large scale traffic due to rapidly growing users. In this paper, wireless internet proxy server clusters are used for the wireless Internet because their caching, distillation, and clustering functions are helpful to overcome the above limitations and needs. TranSend was proposed as a clustering based wireless internet proxy server but it has disadvantages; 1) its scalability is difficult to achieve because there is no systematic way to do it and 2) its structure is complex because of the inefficient communication structure among modules. In our former research, we proposed the All-in-one structure which can be scalable in a systematic way but it also has disadvantages; 1) data sharing among cache servers is not allowed and 2) its communication structure among modules is complex. In this paper, we proposed its improved scheme which has an efficient communication structure among modules and allows data to be shared among cache servers. We performed experiments using 16 PCs and experimental results show 54.86$\%$ and 4.70$\%$ performance improvement of the proposed system compared to TranSend and All-in-one system respectively Due to data sharing amount cache servers, the proposed scheme has an advantage of keeping a fixed size of the total cache memory regardless of cache server numbers. On the contrary, in All-in-one, the total cache memory size increases proportional to the number of cache servers since each cache server should keep all cache data, respectively.

A Novel Fast and High-Performance Image Quality Assessment Metric using a Simple Laplace Operator (단순 라플라스 연산자를 사용한 새로운 고속 및 고성능 영상 화질 측정 척도)

  • Bae, Sung-Ho;Kim, Munchurl
    • Journal of Broadcast Engineering
    • /
    • v.21 no.2
    • /
    • pp.157-168
    • /
    • 2016
  • In image processing and computer vision fields, mean squared error (MSE) has popularly been used as an objective metric in image quality optimization problems due to its desirable mathematical properties such as metricability, differentiability and convexity. However, as known that MSE is not highly correlated with perceived visual quality, much effort has been made to develop new image quality assessment (IQA) metrics having both the desirable mathematical properties aforementioned and high prediction performances for subjective visual quality scores. Although recent IQA metrics having the desirable mathematical properties have shown to give some promising results in prediction performance for visual quality scores, they also have high computation complexities. In order to alleviate this problem, we propose a new fast IQA metric using a simple Laplace operator. Since the Laplace operator used in our IQA metric can not only effectively mimic operations of receptive fields in retina for luminance stimulus but also be simply computed, our IQA metric can yield both very fast processing speed and high prediction performance. In order to verify the effectiveness of the proposed IQA metric, our method is compared to some state-of-the-art IQA metrics. The experimental results showed that the proposed IQA metric has the fastest running speed compared the IQA methods except MSE under comparison. Moreover, our IQA metric achieves the best prediction performance for subjective image quality scores among the state-of-the-art IQA metrics under test.

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .

Fuzzy Control for the Obstacle Avoidance of Remote Control Mobile Robot (원격제어 이동로봇의 장애물 회피를 위한 퍼지 제어)

  • Yeo, Hee-Joo;Sung, Mun-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.47-54
    • /
    • 2011
  • The remote control mobile robot is the robot accomplishing a task according to the orders giving by a user through departed communication system using a joystick. Basically, to supply a lot of information, as this type of robot uses visual information, the user can check the transmitted information by eyes and give orders to the robot. But the weak point of this type of robot is that it has a possibility to come into a collision with an obstacle not be seen to the user because of the communication delay occurring in a communication system and dead zone happening in visual information. To solve the problem, in this paper, we try to suggest a system applying a fuzzy control system to the robot to avoid collision with an obstacle by an immediate order of the user. The fuzzy control system has better performance than any other existing control methods in the change of noise and parameter. And it is more efficient than any other since it solves easy the complexity of the system analysis occurring because of the nonlinear feature of the mobile robot system. In this paper, we made experiments how the mobile robot controlled by the fuzzy control system avoids an obstacle, tracks the path and avoids the obstacle in the path, to prove the performance and to check the evaluation and the application possibility of the fuzzy control system.

Purchase Transaction Similarity Measure Considering Product Taxonomy (상품 분류 체계를 고려한 구매이력 유사도 측정 기법)

  • Yang, Yu-Jeong;Lee, Ki Yong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.9
    • /
    • pp.363-372
    • /
    • 2019
  • A sequence refers to data in which the order exists on the two items, and purchase transaction data in which the products purchased by one customer are listed is one of the representative sequence data. In general, all goods have a product taxonomy, such as category/ sub-category/ sub-sub category, and if they are similar to each other, they are classified into the same category according to their characteristics. Therefore, in this paper, we not only consider the purchase order of products to compare two purchase transaction sequences, but also calculate their similarity by giving a higher score if they are in the same category in spite of their difference. Especially, in order to choose the best similarity measure that directly affects the calculation performance of the purchase transaction sequences, we have compared the performance of three representative similarity measures, the Levenshtein distance, dynamic time warping distance, and the Needleman-Wunsch similarity. We have extended the existing methods to take into account the product taxonomy. For conventional similarity measures, the comparison of goods in two sequences is calculated by simply assigning a value of 0 or 1 according to whether or not the product is matched. However, the proposed method is subdivided to have a value between 0 and 1 using the product taxonomy tree to give a different degree of relevance between the two products, even if they are different products. Through experiments, we have confirmed that the proposed method was measured the similarity more accurately than the previous method. Furthermore, we have confirmed that dynamic time warping distance was the most suitable measure because it considered the degree of association of the product in the sequence and showed good performance for two sequences with different lengths.