• Title/Summary/Keyword: 컴퓨터 교합분석

Search Result 28, Processing Time 0.027 seconds

Finite Element Analysis of Stress Distribution in using Face Mask according to Traction Point (훼이스 마스크의 견인위치에 따른 응력분포에 관한 유한요소법적 연구)

  • Oh, Kyo-chang;Cha, Kyung-Suk;Chung, Dong-hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.171-181
    • /
    • 2009
  • The objective of this study was to analyse stress distribution of maxillary complex by use of face mask. The construction of the three-dimensional FEM model was based on the computed tomography(CT) scans of 13.5 years-old male subject. The CT image were digitized and converted to the finite element model by using the mimics program, with PATRAN. An anteriorly directed force of 500g was applied at the first premolar 45 degrees downwards to the FH plane and at the first molar 20 degrees downwards to the FH plane. When 45 degrees force was applied at maxillary first premolar, there were observed expansion at molar part and constriction at premolar part. The largest displacement was 0.00011mm in the x-axis. In the y-axis, anterior displacement observed generally 0.00030mm at maximum. In the z-axis, maxillary complex was displaced 0.00036 mm forward and downward. When 20 degrees force was applied at maxilla first molar, there were observed expansion at lateral nasal wall and constriction at molar part. The largest displacement was 0.001mm in the X-axis. In the Y-axis, anterior displacement observed generally 0.004mm at maximum. In the Z-axis, ANS was displaced upward and pterygoid complex was displaced downward. The largest displacement was 0.002mm.

Effect of lining application techniques on microleakage in class II composite restorations (다양한 방식으로 적용한 이장재가 2급와동 복합레진 수복의 미세누출에 미치는 영향)

  • Hwang, Byung-Moon;Kim, Joo-Hyung;Park, Ji-Man;Millstein, Philip;Park, Eun-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the microleakage in class II cavity resin restorations used with resin-modified glass ionomer (RMGI) lining material depending on two different applying methods; classical delivery method using a dental explorer and a specially designed rotating bur. Materials and Methods: A total thirty-six extracted teeth were prepared with a class II proximal box, and randomly divided into three groups: 1) control group with no lining added and the proximal box restored (Group I), 2) the second group used RMGI as a lining material which was spread with an explorer (Group II), 3) the third group used a specially designed rotating bur to thin out RMGI (Group III). All teeth were restored with the same manner using incrementally placed resin composite. All 36 teeth were prepared and sectioned for the dye penetration test, and observed with a stereomicroscope for scoring the dye penetration. Results: When RMGI liners were used, both groups using an explorer and the special bur with the liner had significantly less microleakage than the control group with no liner (P < 0.05). The 50% of the group with RMGI liner using the bur showed no microleakage under a dye penetration test whereas all the teeth in control group showed microleakage of different degrees. However, there was no statistically significant difference between Group II and Group III. Conclusion: RMGI is an effective lining material to decrease microleakage in class II composite resin restorations regardless of applying methods.

An analysis on satisfaction level of clinicians on implant surgical guidance system based on computed tomography (컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석)

  • Hong, Min-ho;Jin, Ming-Xu;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.178-185
    • /
    • 2015
  • Purpose: The purpose of this study was to conduct a comparative assessment on the satisfaction level for the two interfaces of surgical guide system (SimPlant and R2GATE), the design and convenience of manufactured surgical guides and the importance of using the surgical guides thereof by means of survey. Materials and Methods: Hereupon, they simulated the implant surgical process by mounting the two manufactured systems of surgical guide on a dental mold, respectively. The study subjects were instructed to complete the questionnaire as to the satisfaction level upon completion of the simulated surgery. This study summarized the data of each question after collecting the completed questionnaires. Then, this study analyzed the summarized data by utilizing statistical program SPSS 20.0 (IBM). Results: R2GATE had a higher value of the satisfaction level on the design and convenience of manufactures surgical guides. R2GATE group ($7.33{\pm}1.26$) was found to have a higher value in terms of the overall satisfaction level compared to SimPlant group ($6.67{\pm}1.26$) (${\alpha}$ = 0.05). Conclusion: The user satisfaction level on the surgical guide manufactured for R2GATE system was to such an extent as it can be widely used in clinical environment. Moreover, the surgical guide manufactured as R2GATE system can guide both the length and direction of a drill simultaneously. As a result, it is highly recommended for those beginners who do not have a lot of experience in implant placement.

The Pattern of Initial Displacement in Lingual Lever Arm Traction of 6 Maxillary Anterior Teeth According to Different Material Properties: 3-D FEA (유한요소모델에서 레버암을 이용한 상악 6전치 설측 견인 시 초기 이동 양상)

  • Choi, In-Ho;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.213-230
    • /
    • 2008
  • The aim of this study was to analyze the initial movement and the stress distribution of each tooth and periodontal ligament during the lingual lever-arm retraction of 6 maxillary incisors using FEA. Two kinds of finite element models were produced: 2-properties model (simple model) and 24-properties model (multi model) according to the material property assignment. The subject was an adult male of 23 years old. The DICOM images through the CT of the patient were converted into the 3D image model of a skull using the Mimics (version 10.11, Materialise's interactive Medical Image Control System, Materialise, Belgium). After series of calculating, remeshing, exporting, importing process and volume mesh process was performed, FEA models were produced. FEA models are consisted of maxilla, maxillary central incisor, lateral incisor, canine, periodontal ligaments and lingual traction arm. The boundary conditions fixed the movements of posterior, sagittal and upper part of the model to the directions of X, Y, Z axis respectively. The model was set to be symmetrical to X axis. Through the center of resistance of maxilla complex, a retraction force of 200g was applied horizontally to the occlusal plane. Under this conditions, the initial movements and stress distributions were evaluated by 3D FEA. In the result, the amount of posterior movement was larger in the multi model than in the simple model as well as the amount of vertically rotation. The pattern of the posterior movement in the central incisors and lateral incisors was controlled tipping movement, and the amount was larger than in the canine. But the amount of root movement of the canine was larger than others. The incisor rotated downwardly and the canines upwardly around contact points of lateral incisor and canine in the both models. The values of stress are similar in the both simple and multi model.

Finite element analysis of the effects of mouthguard produced by combination of layers of different materials on teeth and jaw (다양한 물성을 혼용하여 제작된 구강보호장치가 치아 및 악골에 미치는 영향)

  • So, Woong-Seob;Lee, Hyun-Jong;Choi, Woo-Jin;Hong, Sung-Jin;Ryu, Kyung-Hee;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.324-332
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the stress distribution of teeth and jaw on load by differentiating property of materials according to each layer of widely used mouthguard. Materials and methods: A Korean adult having normal cranium and mandible was selected to examine. A customized mouthguard was constructed by use of DRUFOMAT plate and DRUFOMAT-TE/-SQ of Dreve Co. according to Signature Mouthguard system. The cranium was scanned by means of computed tomography with 1mm interval. It was modeled with CANTIBio BIONIX/Body Builder program and simulated and interpreted using Alter HyperMesh program. The mouthguard was classified as follows according to the layers. (1) soft guard (Bioplast)(SG) (2) hard guard (Duran)(HG) (3) medium guard (Drufomat)(MG) (4) soft layer + hard layer (SG + HG) (5) hard layer + soft layer (HG + SG) (6) soft layer + hard layer + soft layer (SG + HG + SG) (7) hard layer + soft layer + hard layer (HG + SG + HG) The impact locations on mandible were gnathion, the center of inferior border, and the anterior edge of gonial angle. And the impact directions were oblique ($45^{\circ}$). The impact load was 800 N for 0.1 sec. The stress distribution was measured at maxillary teeth, TMJ and maxilla. The statistics were conducted using Repeated ANOVA and in case of difference, Duncan test was used as post analysis. Results: In teeth and maxilla, the mouthguard contacting soft layer of mandibular teeth presented lowest stress measure and, in contrast, in condyle, the mouthguard contacting hard layer of mandibular teeth presented lowest stress measure. Conclusion: For all impact directions, soft layer + hard layer + soft layer, the mouthguard with three layers which the hard layer is sandwiched between two soft layers, showed relatively even distribution of stress in impact.

DENTAL CROWDING AND ITS RELATIONSHIP TO TOOTH SIZE AND ARCH DIMENSION IN KOREAN (한국인에서 치아 및 악궁의 크기와 총생의 관계)

  • Lee, Nan-Young;Hong, Sung-Su;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.510-521
    • /
    • 2006
  • This investigation was undertaken to examine the extent to which tooth size and arch dimension each contribute to dental crowding. The sample included 50 subjects with well aligned dentition (25 males, 25 females) and those of 40 subjects with gross dental crowding(20 males, 20 females). Plaster model and digital model made from alginate impression taken at the one visit. Tooth size, arch length, arch perimeter, intercanine width and intermolar width was measured on the plaster and digital models. The findings in this study lead to the following conclusions. 1. In maxilla, the mesiodistal diameters of lateral incisor and premolars of the crowded group were significantly larger than those of the normal occlusion group (P<0.05). 2. In mandible, the mesiodistal diameters of central incisor, canine and premolars of crowded group were significantly larger than those of the normal occlusion group (P<0.05). 3. In maxilla, arch perimeter and intermolar width of crowded group were significantly smaller than normal occlusion group but intercanine width of crowded group were larger than normal occlusion group (P<0.05). There was no significantly difference in arch length (P>0.05). 4. In mandible, arch perimeter of crowded group was smaller than normal occlusion group(P<0.05). There were no difference in arch length intermolar width and intercanine width (P>0.05) 5. In the analysis of correlation coefficients of arch length discrepancy with variables, arch perimeter, intermolar width and mesiodistal width of 2nd premolar showed positive correlations in maxilla. 6. There was a significant difference between tooth width measurements made by the 2 methods, with all the digital model measurement larger than plaster model measurements (P<0.05) : the magnitude of the differences does not appear to be clinically relevant. 7. In the analysis for reproducibility, the plaster model measurement was showed lower degree of correlation between 1st and 2nd measurement than digital model.

  • PDF

Evaluation of the radiopacity and cytotoxicity of resinous root canal sealers (레진계 근관충전실러의 방사선 불투과성 및 세포 독성에 대한 평가)

  • Kim, Chang-Kyu;Ryu, Hyun-Wook;Chang, Hoon-Sang;Lee, Byung-Do;Min, Kyung-San;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.419-425
    • /
    • 2007
  • The aim of this study was to evaluate the radiopacity and cytotoxicity of three resin-based (AH 26, EZ fill and AD Seal), a zinc oxide-eugenol-based (ZOB Seal), and a calcium hydroxide-based (Sealapex) root canal sealers. Specimens, 10 mm in diameter and 1 mm in thickness, were radiographed simultaneously with an aluminum step wedge using occlusal films, according to ISO 6876/2001 standards. Radiographs were digitized, and the radiopacity of sealers was compared to the different thicknesses of the aluminum step wedge, using the Scion image software. Using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, the cytotoxicity of each material was determined in immortalized human periodontal ligament (IPDL) cells. The results demonstrated that EZ fill was the most radiopaque sealer, while Sealapex was the least radiopaque (p < 0.05). AH 26, AD Seal and ZOB Seal presented intermediate radiopacity values. All the materials evaluated, except for Sealapex, presented the minimum radiopacity required by ISO standards. The cell viabilities of resin-based root canal sealers were statistically higher than that of other type of root canal sealers through the all experimental time. Further, EZ fill showed statistically lower cell viability in 24 and 48 hours compared to AD Seal and in 72 hours compared to all other resin-based root canal sealers. However, there was no correlation between the radiopacity and cytotoxicity of three resin-based root canals sealers (p > 0.05). These results indicate that resin-based root canal sealer is more biocompatible and has advantage in terms of radiopacity.

A study on the smile of Korean Youth compared with twenty years ago (20년전과 비교한 한국청년의 미소 변화에 관한 연구)

  • Beom, Seung-Gyun;Jung, Ji-Hye;Kim, Tae-Young;Lee, Kyung-Eun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • Purpose: Teeth are generally exposed when people smiling. Moreover, the exposed teeth and soft tissue when smiling becomes an important guideline for esthetically prosthetic restoration. This research is to compare and find out differences of Korean young men's smile living in presence and twenty years ago. Materials and methods: Subjects, 100 young men (50 male and 50 female), were required about several aspects; normally developed physical condition, no psychological or genetic disorders, a fine face with no loss of teeth, no experience in orthodontic or prosthetic treatment, relatively normal occlusion, aged between 20-29. The photos of the subject at rest position and front face when fully smiled were taken three times. 100 photos (50 male and 50 female) were chosen at random from the 240 university students' smile photos taken by Yoon and his colleagues in 1991. By Hulsey's method of measuring smile, several factors; the change of upper lip curvature, the change of the relation between the upper lip and teeth, parallelism between Mx. incisor and lower lip, contact relation between Mx. incisor and lower lip and teeth displayed in a smile, were measured and analyzed. Meanwhile, ten dentists assessed aesthetic evaluation about men and women's smile for twice and recorded and compared smile score. The -test (P<.05) was used to compare the measured value. The difference of smile score was analyzed by t-test (P<.05). Results: The smile score calculated in 2011 (60.22) was higher than that of 1991 (52.80). Among five measurement categories, the noticeable difference was distinguished from two factors; the change of upper lip curvature and contact relation between Mx. incisor and lower lip. Conclusion: The Korean young men's smile has been considerably improved for twenty years. And it is found that the change of upper lip curvature plays an important role, that is, the smile formed with an ascended labial commissure has been increased significantly.