• 제목/요약/키워드: 컴퓨터단층촬영검사

Search Result 234, Processing Time 0.024 seconds

Endovascular Repair of Acute Type B Aortic Dissection: The Early Results and Aortic Wall Changes (급성 B형 대동맥 박리의 혈관내 스텐트-그라프트 삽입이 초기성적 및 대동맥 벽의 변화)

  • Her, Keun;Won, Yong-Soon;Shin, Hwa-Kyun;Yang, Jin-Sung;Baek, Kang-Seok
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.648-654
    • /
    • 2010
  • Background: This study assessed the early results of endovascular repair of acute type B aortic dissection and the aortic wall changes following endovascular repair. Material and Method: From July 2008 to May 2009, the preoperative and follow-up computed tomography (CT) scans of 5 patients with acute type B aortic dissection were evaluated, and these patients had underwent stent graft implantation within 13 days of the onset of dissection (mean: 7 days; range: 3~13). The whole lumen (WL), true lumen (TL) and false lumen (FL) diameters were measured at the proximal (p), middle (m) and distal (d) third of the descending thoracic aorta. Result: The study included four men and one woman with an average age of $59.4{\pm}20.1$ years (age range: 37~79 years). The follow-up CT was performed and evaluated at 7 days and 6 months. The primary tear was completely sealed in all the patients. No paraplegia, paresis or peripheral ischemia occurred and none of the patients died. No endoleaks developed in any of the patients during follow-up. The TL diameters increased from 20.4 to 33.5 mm in the proximal third (p/3), from 19.5 to 29.8 mm in the middle third (m/3) and from 15.2 to 23.5 mm in the distal third (d/3). The FL diameters decreased from 18.7 to 0 mm in the p/3, from 15.4 to 0 mm in the m/3 and from 21.4 to 8.7 mm in the d/3. The changes in the TL diameter were statistically significant in the middle and distal aorta, and those changes in the FL diameter were not statistically significant. There was a decrease in the WL after repair, but this was not statistically Significant. In three patients, the false lumen disappeared completely on follow-up CT at 6 months. Two patients had patent false lumens and no thrombosis. Conclusion: The early results showed that endovascular repair was effective in treating acute type B aortic dissection, and endovascular repair promoted positive aortic wall changes.

Clinical Characteristics of Orbital Cellulitis in Children (소아 안와 연조직염의 임상적 고찰)

  • Lee, Yong Ju;Choi, Kyoung Min;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.178-185
    • /
    • 2005
  • Purpose : Ocular adnexal and orbital infections are broadly divided into preseptal(periorbital) and postseptal(orbital) cellulitis by orbital septum. In this study, we investigated the difference between periorbital and orbital cellulitis regarding their pathogenesis, clinical manifestations, treatments, and prognosis. Methods : We reviewed medical records of 50 cases who were hospitalized in the Severance hospital due to orbital cellulitis from May 1995 to April 2004. Results : There were 32 males and 18 females. The mean age was $3.2{\pm}3.5$ year. According to the result of orbital computerized tomography, 36 cases were periorbital cellulitis, 10 cases orbital cellulitis and 4 cases not diagnosed. The clinical manifestations of periorbital cellulitis are periorbital swelling(100%), fever(19%), orbital pain(6%), and chemosis(22%). On the other hand, those of orbital cellulitis are periorbital swelling(100%), fever(80%), orbital pain(60%), proptosis(20%), chemosis(70%) and limitation of eye movement(20%). The etiologies of periorbital cellulitis are sinusitis(14%), upper respiratory infection(8%), conjunctivitis (19%), skin wound(14%) and unknown(44%). The etiologies of orbital cellulitis are sinusitis (50%), upper respiratory infection(20%), and unknown(30%). The first line antibiotics used in the majority of cases were combinations of cefoxitin+aminoglycoside. 5 patients with orbital cellulitis taking cefoxitin+aminoglycoside had to change the medication into vancomycin or clindamycin. 3 patients with orbital cellulitis underwent operation while 1 patient developed bacterial meningitis. Conclusion : According to invasion of orbit, ocular adnexal and orbital infections are quite different in their pathogenesis, treatment and prognosis. As atypical cases may confound the diagnosis, prompt orbital computerized tomography is required for an accurate diagnosis.

  • PDF

A Clinical Study of Acute Colonic Diverticulitis in Children (소아에서 발생한 급성 대장 게실염의 임상적 고찰)

  • Sim, Jae Hoon;Song, Keum Ho;Sim, Yun Jung;Cho, Do Jun;Kim, Dug Ha;Min, Ki Sik;Yoo, Ki Yang;Lee, Hae Ran;Lee, Kwan Seop
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.11
    • /
    • pp.1095-1100
    • /
    • 2003
  • Purpose : Children with acute colonic diverticulitis(ACD), can be misdiagnosed with acute appendicitis. Methods : We reviewed 15 cases of ACD during five years, from January 1998 to June 2002 retrospectively. Results : Most patients(80%) with ACD in children presented with right lower quadrant pain. The primary diagnosis on admission was mostly acute appendicitis(87%), and all ACD in children occurred in the right colon. Fourteen patients were managed by conservative treatment including antibiotics. A follow-up study was performed in 15 patients. There were symptomatic recurrences in two patients, but no significant complication was noted. The frequency of ACD was 11.7 per 1000 acute appendicitis. Conclusion : ACD in children can mostly be cured by conservative treatment. It is prudent to choose the management through the diagnostic work up, including abdominal sonography and computed tomography, because there was no significant difference of clinical findings between ACD and acute appendicitis.

Is Preventive Bilateral Surgery Needed in Case of Bilateral Bullae on HRCT at Unilateral Primary Spontaneous Pneumothorax (일차성 자연기흉의 고해상 CT에서 보이는 반대편 기포의 예방적 기포절제술이 필요한가?)

  • Han, Jong-Hee;Kang, Min-Woong;Yu, Jeong-Hwan;Kim, Yong-Ho;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.215-219
    • /
    • 2007
  • Background: Due to the advancement of video assisted thoracoscopic techniques, an operation for primary spontaneous pneumothorax is now considered a common procedure. However, whether a preventive operation is necessary when a contralateral bulla is found on High Resolution Computed Tomography (HRCT) at the time of the first primary spontaneous pneumothorax attack is still unknown. In this retrospective study, it was our intension to find whether contralateral bullae are related to the occurrence of pneumothorax. Material and Method: Between January 1999 and April 2006, 550 patients were admitted to the Chungnam University hospital with primary spontaneous pneumothorax, which was confirmed by the HRCT scans in 190 patents. In these 190 patients, 159 had not received a bilateral operation after their first primary spontaneous pneumothorax attack. In these 159 patients, the relationship between the presence of contralateral bullae and the occurrence of pneumothorax was measured. Result: In these 159 patients, 67 had contralateral bullae confirmed inform the HRCT scan, and 92 had no visible contralateral bullae, During the follow up period, 6 patients (8.9%) with contralateral bullae had an occurrence of contralateral pneumothorax, and 5 patients (5.4%) without contralateral bullae had an occurrence of contralateral pneumothorax. (p=0.529 [Fisher's exact test]) Conclusion: In patients with unilateral primary pneumothorax, an HRCT scan is a useful way of confirming contralateral pulmonary bullae. However, the presence of bullae is not a significant predictive sign of an occurrence of contralateral pneumothorax. Also, surgery for pneumothorax is not completely uncomplicated, and bilateral surgery is still doubtful. A further prospective study will be required to find the relationship between the bullae found on HRCT and the occurrence of pneumothorax.

Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report (무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례)

  • Ko, Kyoung-Ho;Lim, Kwang-Gil;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.233-245
    • /
    • 2011
  • With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.

Arthroscopic Iliopsoas Tenotomy of Iliopsoas Impingement after Total Hip Arthroplasty (고관절 전치환술 후 발생한 장요건 충돌의 관절경하 장요건 절단술)

  • Huh, Soon Ho;Choi, Byeong Yeol;Han, Sang Roc;Chung, Woo Chull
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.125-133
    • /
    • 2021
  • Purpose: The clinical outcomes were investigated to determine if arthroscopic management is a useful method for 19 hips with iliopsoas tendon impingement (IPI) after total hip arthroplasty (THA). Materials and Methods: Eighteen patients (19 hips), who complained of groin pain and flexion pain that persisted after THA from September 2013 to December 2019, were the subjects of this investigation. The mean time to manifestation after THA was four months (range, 1-9 months) in patients of an average age of 60 years (range, 50-69 years). Thirteen out of 18 patients underwent THA using the direct anterior approach and five by the lateral approach. IPI was diagnosed by the medical history, physical examination, blood test, radiographic examination using X-ray and computed tomography, and topical injection therapy. All patients underwent arthroscopic treatment and a dynamic arthroscopic physical examination after exposure to the iliopsoas tendon revealed impingement. Tenotomy was then performed on the muscle portion through the total tendon portion. Symptoms and pain levels of preoperative, postoperative and follow-up period were investigated and compared. Results: The Western Ontario and McMaster Universities Osteoarthritis Index score decreased from an average of 58.4 (range, 40-88) before surgery to an average of 35.0 (range, 15-76) after surgery. Similarly, the visual analogue scale decreased from an average of 4.0 (range, 2-6) before surgery to an average of 1.4 (range, 0-4) after surgery. Sixteen patients (88.9%) showed pain relief and improvement in the straight leg raise test, and two patients showed postoperative muscle weakness and sustained pain. In the follow-up period, muscle weakness improved. One patient underwent arthroscopic iliopsoas tenotomy at the lesser trochanteric level but the symptoms persisted. The clinical symptoms were improved after one more tenotomy at the joint level. Conclusion: Arthroscopic iliopsoas tenotomy performed in patients with IPI after THA showed good clinical results.

Research and Consideration of Eco-friendly Radiation Shielding using CT Contrast Agent (CT 조영제를 이용한 친환경적인 방사선 차폐에 관한 연구 및 고찰)

  • Sung-Gil Kim;Yeon-Sang Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.827-833
    • /
    • 2023
  • CT(Computed Tomography) contrast agents are commonly used in general hospitals and university hospitals when taking radiographic examinations. The CT contrast medium contains a mixture of a substance called "Iodine", which absorbs radiation energy and makes it appear white in the CT image, further improving the image quality. In addition, the CT contrast agent, which moves like blood in the blood vessels, clearly differentiates it from muscle and water, so CT contrast agents are widely used in hospitals. These CT contrast agents absorb X-rays, but in order to absorb X-rays, they must have a high density or a high radiation absorption coefficient. Since the CT contrast agent is injected into the blood vessels, if the density is high, the blood vessels are strained and the patient is in shock. For this reason, it is necessary to match the density similar to that of water and always pay attention to side effects. In addition, the amount of CT contrast medium is adjusted according to the patient's body shape, and the remaining contrast medium is discarded. However, This study tried to find out the idea of recycling it as a radiation shielding material. Since the CT contrast medium has a high radiation absorption coefficient at a density similar to that of water, the amount to absorb radiation is adjusted, the amount of contrast medium and the amount of water are adjusted, and the amount of radiation absorbed is determined by mixing with water. In addition, a study was conducted to find out the result of the difference in radiation absorption in various ways by comparing the radiation quality coefficient and absorption coefficient with other substances or materials in an environmentally friendly method harmless to the human body by mixing CT contrast medium and water.

The Utility of Scalene Lymph Node Biopsy in the Diagnosis of Sarcoidosis (유육종증 진단에서의 사각근 림프절 생검의 유용성)

  • Chung, Won-Sang;Kim, Young-Hak;Song, Young-Joo;Kim, Ji-Hoon;Kim, Hyuck
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.694-699
    • /
    • 2010
  • Background: In addition to clinical and radiographic findings, a histopathologic examination is important in the diagnosis of sarcoidosis. This study evaluated the diagnostic usefulness of a scalene node biopsy in patients with suspected sarcoidosis. Material and Method: We studied 35 patients who underwent scalene node biopsy because of suspicion of sarcoidosis on a chest x-ray and a computerized tomogram between 2001 and 2009, regardless of symptoms. Result We studied 15 men and 20 women whose mean age was $41.51{\pm}11.21$ years (25~64). Three among the 35 were diagnosed with tuberculosis and 27 with sarcoidosis, resulting in a diagnostic yield of 84.4%. The mean lymph node diameter size was 1.3 (${\pm}0.12$) (0.3~3.6 cm) cm. We divided the group of participants according to stage - whether on chest x-ray the lung was affected or not (stage 0, 1 and stage 2, 3). We divided lymph node sizes as well - whether they were larger than 1 cm or smaller than 1 cm. For these subgroups, there were no significant differences in diagnostic yield (p=0.604) (p=0.084). There were no complications or mortality. Conclusion: Scalene node biopsies are simply done under local anesthesia, without major complications. They have a high diagnostic yield regardless of the stages of the disease and lymph node size. We conclude that scalene node biopsy is a good alternative to other biopsy methods in sarcoidosis.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

Usefulness of $^{18}F$-Fluoride PET/CT in Bone Metastasis of Prostate Cancer (전립선암 환자의 뼈 전이에 대한 $^{18}F$-Fluoride PET/CT의 유용성)

  • Park, Min-Soo;Kim, Jung-Yul;Park, Hoon-Hee;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.24-30
    • /
    • 2009
  • Purpose: Today, Prostate cancer has been gradually increasing, according to the change of internal incidence rate of cancer. Generally, prostate cancer has lead to dead over 90%, in case of metastasis of lymph node and bone. So, innovative development of new radiopharmaceutical and imaging modality is progressed for detection of that metastasis, in nuclear medicine, now. Therefore, this study shows the usefulness of $^{18}F$-Fluoride PET/CT improved diagnosability on bone metastasis of prostate cancer. Materials and Methods: In this study, 33 male patients with prostate cancer were examined (The mean age: $67.8{\pm}10.2$ years old). Every patient was done each whole body bone scan (WBBS) and $^{18}F$-Fluoride positron emission tomography/computed tomography ($^{18}F$-Fluoride PET/CT). And then, using Receiver Operating Characteristic Curve (ROC curve), each sensitivity and specificity of two modalities was measured and compared with. Results: In 22 patients (66.6%) of all, bone metastasis was detected. And, in WBBS, sensitivity was 63.6%, specificity, 81.8%; in $^{18}F$-Fluoride PET/CT, sensitivity was 100% and specificity was 90.9%. As a result of ROC curve, AUROC (The Area under an ROC) of WBBS was 0.778, and that of $^{18}F$-Fluoride PET/CT, 0.942. Conclusions: $^{18}F$-Fluoride PET/CT was higher both sensitivity and specificity than WBBS, and it was valuable to detect bone metastasis of prostate cancer more definitely, with 3D imaging realization. Also, in $^{18}F$-Fluoride PET/CT, physiological images were acquired in more short time than WBBS, so, it was possible to reduce patient's waiting time and complaint. Therefore, it is considered that $^{18}F$-Fluoride PET/CT is able to improve diagnosability by offering more accurate images, as cuts in a share of high cost.

  • PDF