• Title/Summary/Keyword: 컬럼높이

Search Result 18, Processing Time 0.018 seconds

The Effect of Column Height on Sludge-Water Interface Height Change Model (슬러지계면층높이변화모델에서 컬럼높이에 대한 영향)

  • Park, Suk Gyun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.265-272
    • /
    • 2006
  • While sludge settles down in a column, sludge settling characteristic is influenced by effect parameters, interparticle force, wall effect etc. As the height of a column changes, the settling velocity of sludge-water interface changes, too. At lower sludge concentration, particular effect was not observed by the difference of column height, however it was observed that settleability of sludge was greatly influenced by column height when sludge settling was poor or sludge concentration was high. It is therefore required to consider the effect of column height when the power model for sludge interface settling is established. In the tests, there was hardly any $SVI_{ts}$(SVI after "t" minutes) difference in each column after 10min at $1.5kg/m^3$ of sludge concentration. When sludge concentration was at $2.5kg/m^3$, $SVI_{ts}$ tended to be constant after 20min. At $3.5kg/m^3$, $SVI_{ts}$ increased to 30minuets. The purpose of this work is to establish the correction factor that is able to compensate the errors derived from each different height of column.

Integrating Query Column-Sets and Horizontal Partitions on Very Large Data (대용량 데이터 처리를 위한 질의 컬럼셋과 수평 파티션의 통합 방법)

  • Chung, Moonyoung;Lee, Taewhi;Kim, Sung-Soo;Song, Hyewon;Won, Jongho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.521-522
    • /
    • 2016
  • 분산된 테이터에 대한 질의 처리에서는 중간 데이터를 전송하는 단계에서 많은 디스크 I/O 및 네트워크 트래픽을 야기할 수 있다. 따라서, 질의에 필요하지 않은 데이터를 미리 필터링하면 불필요한 I/O 및 네트워크 전송을 줄일 수 있어 질의 처리 성능을 높일 수 있다. 이 논문에서는 질의 컬럼셋과 수평 파티션 방법을 통합하여 질의 처리에 불필요한 데이터를 초기 단계에 미리 필터링하여 질의 처리 성능을 높이는 방법을 제안한다.

Prediction of Sludge-Water Interface Height Change in Batch Column (Batch Column에서의 슬러지계면층 높이변화 예측)

  • Park, Suk Gyun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.156-163
    • /
    • 2006
  • While sludge is settling in batch column, sludge concentration becomes high. Because the characteristic of sludge settling changes in function of time due to the sludge concentration change, the sludge settling velocity changes too. Also, because the sludge settling characteristic is influenced by a physical characteristic of sludge and a column height etc, it is difficult to exactly measure the sludge settling characteristic. Although the sludge volume indexes, SVI, SSVI and $SSVI_{3.5}$, are used to predict sludge settling characteristic, these indexes are not reliable values. Because the previously established models for sludge settling velocity predict the sludge settling velocity only, it is difficult to predict sluge-water interface height by using those models. The purpose of this experiment is to establish the empirical model which predicts the sludge interface height change with respect to the sludge physical characteristic and the settling condition.

Studies on Simultaneous Analysis of Organophosphorus Pesticide Residues in Crops by Gas-Liquid Chromatography (II). Separation of Pesticides by Capillary Column (기체-액체 크로마토그래피에 의한 농작물 중 유기인제 잔류농약의 동시 분석에 관한 연구 (제 2 보). 모세관 컬럼에 의한 분리)

  • Kim, Taek-Jae;Eo, Yun-Woo;Kim, Young-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.3
    • /
    • pp.236-243
    • /
    • 1987
  • The optimum resolution condition of 11 organophosphorus pesticides by gas-liquid chromatography was studied using a capillary column. The injection modes and types of vaporization tubes were evaluated in relation to pesticide analysis. The best reproducibility of peak heights of pesticides was obtained by the split mode with the vaporization tube packed with quartz wool. A 25m SE-30 capillary column provided better resolution than SE-54 column for their optimum resolution. The column at $200^{\circ}C$ initially was heated by $5^{\circ}C/min\;to\;230^{\circ}C$ followed by $10^{\circ}C/min\;to\;270^{\circ}C$ and the temperatures were held constant for 5 minutes at $230^{\circ}C\;and\;270^{\circ}C$, respectively. The relative standard deviations of their retention times were less than 0.19%.

  • PDF

The investigation of adsorption properties of filter media for removal efficiency of nitrogen, phosphorus using experimental and density functional theory (실험 및 밀도범함수이론을 이용한 질소, 인 저감 효과 분석을 위한 여재의 흡착 특성 연구)

  • Kim, Taeyoon;Kwon, Yongju;Kang, Choonghyun;Kim, Jongyoung;Shin, Hyun Suk;Kwon, Soonchul;Cha, Sung Min
    • Journal of Wetlands Research
    • /
    • v.20 no.3
    • /
    • pp.263-271
    • /
    • 2018
  • In this study, we analyzed the removal efficiency of ammonia nitrogen and phosphate dependant on the column depths using various absorbents such as zeolite silica sand, and activated carbon through the column test. In addition, we analyzed electrochemical adsorption behaviors of ammonia nitrogen and phosphate through the quantum mechanical calculation based on density functional theory calculation. Experimental results represent the removal efficiency of ammonia nitrogen and phosphate are zeolite > activated carbon > silica sand, and activated carbon > zeolite > silica sand, respectively. Zeolite shows high adsorption property for ammonia nitrogen over 90%, regardless of the column depth, while activated carbon exhibits high adsorption property for both ammonia nitrogen and phosphate as the column depth for filter media increases. Theoretical findings using DFT calculation for the adsorption behaviors of adsorbents (activated carbon and silica sand) and nutrients ($PO_4{^{3-}}$, $NH_4{^{+}}$) show that activated carbon represented narrower HOMO-LUMO band gap with high adsorption energy, and even more favorable environment for electron adsorption than silica sand, which leads to the effective removal of nutrients.

Removal Characteristics of Lithium Ions by Fixed-bed Column Packed with Strong-Acid Cation Exchange Resin (강산성 양이온 교환수지를 충전한 고정층에서 리튬이온의 제거특성)

  • You, Hae-Na;Lee, Min-Gyu
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.166-170
    • /
    • 2014
  • The continuous experiments were carried out using fixed-bed column packed with strong-acid cation exchange resin for the removal of lithium ions from aqueous solution. The parameters such as bed height, flow rate and inlet concentration were investigated. Breakthrough time ($t_{0.05}$), saturation time ($t_{0.95}$), and total amount of lithium ion removed (mtotal) were obtained from the breakthrough curves. The results showed that $t_{0.05}$ and $t_{0.95}$ decreased with decreasing bed height, and decreased with increasing inlet concentration and flow rate. mtotal increased with increasing inlet concentration and bed height, but decreased with increasing flow rate. Thomas model and Yoon-Nelson model equations were applied to the experimental data, the results showed that the breakthrough data gave a good fit to Thomas model equation.

Separation of High Purity Terbium Using Extraction Chromatography (추출 크로마토그래피를 이용한 고순도 테르븀의 분리)

  • Lee, Kwang-Pill;Park, Myoung-Jin;Park, Keung-Shik;Lee, Hueng-Lark;Piao, Zhexiu
    • Analytical Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.370-374
    • /
    • 1999
  • Extraction chromatography was used to scarch optimum separation conditions of terbium. Stationary phase was 2-ethylhexyl-2-ethylhexyl phosphonic acid(HEH[EHP])levextrel (-100~+150 mesh), column size was ${\Phi}20{\times}530mm$ and kept constantly temperature at $50^{\circ}C$, adsorption flow rate of $0.2mL/cm^2{\cdot}min$, elution flow rate of $1.0mL/cm^2{\cdot}min$, column diameter to packing height of 1:15. But to search optimum separation conditions of terbium, it changed the eluent acidity, the loading weight of sample. the composition of sample. In conclusion, acidity was 0.6 N HCl, loading weight of sample was about 5% and composition of sample was $Gd_2O_3(20%)+Tb_4O_7(60%)+Dy_2O_3(20%)$. Moreover purity of separated terbium by ICP-AES analysis was 99.98% in yield of 99.99%.

  • PDF

Separation and Determination of Co(II) and Ni(II) Ion as their 4-(2-Pyridylazo) resorcinol Chelates by Reversed-Phase Capillary High-Performance Liquid Chromatography (역상 모세관-고성능 액체 크로마토그래피에 의한 코발트와 니켈 이온의 4-(2-피리딜아조)레조루신올 킬레이트로서의 분리 및 정량)

  • Chung, Yong-Soon;Chung, Won-Seog
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.547-552
    • /
    • 2003
  • Separation and determinations of Co(II) and Ni(II) ions as their 4-(2-pyridylazo)resorcinol(PAR) chelates by reversed-phase capillary high-performance liquid chromatography(RP-CpHPLC) were performed. Among many capillary columns, Vydac C4 column was selected and acetonitrile solution was used as mobile phase. The effect of pH and MeCN concentration(%) on the retention factor, k and peak intensity was examined and discussed. As a results, it was found that 22.5% MeCN and pH 5.60 was adequate as mobile phase for the separation of the two metal ions and determination of Co(II) ion, but the mobile phase condition for Ni(II) ion determination was 22.5% MeCN of pH 7.20. Detection limit(D.L., S/N=3) of Co(II) and Ni(II) ions were $2.0{\times}10{-7}$ M(14.9 ppb) and $1.0{\times}10{-6}$ M(59.2 ppb), respectively.

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF

The Effect of Temperature and Flow Rate of Eluent on the Separation of Adjacent Lanthanides (La : Ce, Ce : Pr, Pr : Nd) with Displacement Chromatography (치환크로마토그래피에서 온도와 용리액의 흐름속도가 란탄족 원소들 (La : Ce, Ce : Pr, Pr : Nd) 의 분리에 미치는 영향)

  • Ha, Yeong Gu;Song, Gi Hun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.9
    • /
    • pp.660-666
    • /
    • 1994
  • The effects of temperature and flow rate of eluent on the separation of adjacent lighter lanthanide pairs (La : Ce, Ce : Pr, Pr: Nd) have been studied with displacement chromatography. Two serial columns packed with Amberlite 120 cation exchange resin are used for loading and separation. The retaining ion is $H^+$ ion and the eluent is 0.012M and 0.015M of EDTA solution. The columns and the eluent are maintained at the temperature of 90$^{\circ}C$ and pressurized to reduce vaporizing in the ion-exchange resin column. The eluated solution is analyzed directly with ICP-AES. The separation factors of the lanthanide pairs, La: Ce, Ce :Pr, and Pr: Nd, are 4.6, 2.8, and 1.9, respectively and are higher than that from theoretical calculation at 25$^{\circ}C$. When the flow rate is reduced from 2.5 ml/min to 1.5 ml/min, the HETP is reduced from 1.60 cm to 0.88 cm. The separation efficency can be improved at lower flow rate of eluent and higher operating temperature. The recoveries of pure lanthanides than 99.9% are 49∼77% from this separation.

  • PDF