• Title/Summary/Keyword: 컬러도플러 초음파

Search Result 15, Processing Time 0.022 seconds

Renal hemodynamics in dogs with experimental hydronephrosis treated with transarterial embolization of renal artery (신장동맥색전술을 실시한 개의 실험적 수신증의 혈동학)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.413-419
    • /
    • 2001
  • This study was performed to evaluate the renal hemodynamics using color Doppler ultrasonography in dogs with unilateral experimental hydronephrosis treated with transarterial embolization of the renal artery (TAE-RA). Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. The mean resistive index (RI) value of kidney was significantly increased at 4, 9, 17 days after ligation of ureter. Unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$body temperature, pulse, and respiratory rate were within normal ranges during procedures. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. In color Doppler ultrasonographic findings, there was no blood flow into the embolized kidneys treated by TAE-RA, however, blood flow signal was found in contralateral normal kidney of dogs treated with TAE-RA compared to that of normal kidney in normal control group. It is concluded that TAE-RA does not affect the hemodynamics of contralateral normal kidney in dogs with experimental hydronephrosis and color Doppler ultrasonography is simple and non-invasive modality for the monitoring of the revascularization of the renal artery after TAE-RA.

  • PDF

A Study on Changes in Body Surface Temperature and Thermal Effect According to Ultrasound Mode (초음파 진단모드에 따른 체표면 온도변화와 열효과에 관한 고찰)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.213-218
    • /
    • 2017
  • Recently, as the number of high-risk pregnancies increases, the use of new techniques such as Doppler, which have higher acoustic power than in the past, has been increasingly used in prenatal diagnosis and guidelines have been set up by various organizations to prevent excessive exposure. Therefore, in this study, we tried to investigate the temperature change of the body surface for each test mode according to the long time ultrasound examination and to examine the exposure time which is not influenced by the thermal effect. B mode, C mode, and PD mode according to time, and the temperature difference between exposed and unexposed sites were compared. As a result, the B mode showed a significant difference in the temperature change from 10 minutes, 50 minutes after exposed, 20 minutes from the C mode, and 30 minutes from the PD mode (p<0.01). In all three modes, the temperature difference was different (p<0.000), and PD mode was the most sensitive to temperature change. Also, it was found that the temperature rise time was shortened with the increase of the ultrasonic exposure time. Therefore, it is recommended that ultrasonography to observe the embryo or fetus should be used only for diagnostic purposes, avoiding excessive test time.

Fate of Regurgitation of Left Atrioventricular Valve Following Repair of Atrioventricular Septal Defect (완전 방실중격결손증의 수술적 교정 후 잔존 좌측 방실판막부전에 대한 장기적 임상 경과 관찰)

  • 김시호;박한기;장병철;조범구;방정희;박영환
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.961-969
    • /
    • 2003
  • The purpose of this study was to evaluate the fate of left atrioventricular valve regurgitation(LAVVR) following repair of complete atrioventricular septal defects (AVSDs). Material and Method: Between July 1984 and March 2002, repair of complete AV defects were performed in 77 patients. Mean age at surgery was 30.23$\pm$69.11 months (range 1 to 456). Echocardiograms of all survivors after isolated AVSDs correction were reviewed. LAVVR were evaluated with color doppler echocardiography in 64 survival periodically. On each study, LAVVR severity was graded on a 1 to 4 scale, based upon the size of the regurgitated jet. Result: Mild deterioration of LAVV function was fairly common. LAVVR severity increased by >1 grade in 19 patients (30.2%) during the course of the study. However, the deterioration in LAVVR function occurred primarily between 12 and 24 months postoperatively. After the initial 24 postoperative months, LAVVR worsened on only 8 occasions and in each instance worsened by only 1 grade. Deterioration more than 3+ LAVVR occurred in only 3 patients. And deterioration to 4+ LAVVR was not observed after the initial 24 postoperative months but one. Survival curve analysis predicted a 88.2% of ten-year freedom rate from development of 4+ LAVVR after initial operation of complete AVSDs. Conclusion: Postoperative LAVVR remains fairly stable following AVSDs repair, Serious deterioration is rare after 24 postoperative months, especially after the initial 48 postoperative months. But serial follow-up study with echocariogram was need till 24 postoperative months after repair of complete AVSDs.

Use of the Color Doppler Ultrasonography for the Evaluation of the Hemodynamic Changes of the Cranial Pancreaticoduodenal Arterial Flow in Experimentally Induced Acute Pancreatitis Dogs (실험적으로 유발된 급성 췌장염 견에서 컬러도플러 초음파를 이용한 전방 십이지장 동맥 혈류의 혈역학적 변화에 대한 평가)

  • Lee, Hae-Woon;Um, Ki-Dong;Sung, Yoon-Sang;Lee, Jung-Min;Lee, Jong-Won;Lee, Geun-Woo;Kim, Myung-Chul;Kim, Doo;Park, Sun-Il
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.334-340
    • /
    • 2003
  • For the study of the hemodynamic changes of the cranial pancreaticoduodenal arterial flow(cPDAF) in the dog with acute pancreatitis, acute pancreatitis was experimentally induced in 10 dogs by the injection of oleic acid into the accessory pancreatic duct. The parameters of cPDAF were measured by transcutaneous pulsed-wave Doppler ultrasonography. The hemodynamic changes included resistive indexe(RI), pulsatility index(PI) and maximum velocity (Vmax). Ultrasonographic scans were performed before the induction of pancreatitis and once daily for five days after the induction. The RI, PI and Vmax were increased with day as follows; the RI prior to induction was 0.625$\pm$0.096 (mean$\pm$SD), the PI was 1.117$\pm$0.289 and the Vmax was 0.349$\pm$0.094 m/s. After five days, the RI was 0.727$\pm$0.051 (p<0.0l), the PI was 1.480$\pm$0.284 (p<0.0l) and the Vmax was 0.585:$\pm$0.114 m/s (p<0.00l). These results show that there is some relation between the increase of the RI, PI and Vmax of cPDAF and the progress of acute pancreatitis in dogs. Therefore, the measurements of the hemodynamic changes of cPDAF may be a valuable technique for the evaluation of acute pancreatitis in dogs.

Treatment of giant iatrogenic pseudoaneurysm of the femoral artery (대퇴동맥에 발생한 의인성 거대 가성동맥류에 대한 치료)

  • Kang, Wu-Seong;Park, Chan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.423-428
    • /
    • 2019
  • The role of angioembolization has increased because of increases in nonoperative treatment for traumatic splenic injury. We report here a case of successful treatment of iatrogenic pseudoaneurysm of the femoral artery by thrombin injection with coil embolization. A 55-year-old female was admitted to our hospital because of blunt trauma. Computed tomography (CT) revealed a grade V splenic injury with contrast extravasation; therefore, angioembolization was performed. Three days after admission, follow-up CT scan revealed rebleeding from the spleen, and repeat angioembolization was performed. Seven days after admission, an approximately $7.0cm{\times}4.0cm-sized$ pseudoaneurysm was found on follow-up CT scan and there was no bleeding from the spleen. Although thrombin was injected into the aneurysmal sac, there was still inflow of blood, as observed on color-doppler ultrasound. Therefore, coil embolization to the neck of the aneurysm was performed. On angiography, there was no contrast filling into the sac. The size of the pseudoaneurysmal sac had decreased on follow-up CT scan, and the patient was discharged to home without complications. We successfully treated a giant pseudoaneurysm of the femoral artery using thrombin and coil embolization.