• Title/Summary/Keyword: 카트리지

Search Result 209, Processing Time 0.033 seconds

The Development of Pyrotechnically Releasable Mechanical Linking Device Using Pressure Cartridge (압력카트리지를 이용한 파이로 분리장치 개발)

  • Kim, Dong-Jin;Lee, Yeung-Jo;Ko, Young-Kyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.340-343
    • /
    • 2011
  • Explosive bolts are reliable and efficient mechanical fastening devices having the special feature of a built-in release. The disadvantage of explosive bolt lies in that it is based on the high explosive effect of a pyrotechnic charge. The aim of the present work is to propose a pyrotechnically releasable mechanical linking device for two mechanical elements that does not suffer from such drawbacks. The pyro-lock using the pressure cartridge has the release characteristic without fragmentation and minimum pyro-shock. The present work is focused on the design, the interpretation of structure, the separation mechanism, separation force, and the results of various tests.

  • PDF

The study of analytical method for sulfonamide antibiotics and their metabolites in environmental samples (환경 시료 중 설폰아미드계 항생제 및 대사체 분석방법 연구)

  • Kang, Young-Yeul;Hwang, Seung-Ryul;Shin, Sun-Kyoung;Koo, So-Hyun;Sim, Ki-Tae;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.437-445
    • /
    • 2010
  • The aim of this study was to develop an analytical method for sulfonamide antibiotics (sulfadiazine, sulfamerazine, sulfamethazine, sulfamethoxazole, sulfathiazole) and their metabolites ($N^4$-acetylsulfadiazine, $N^4$-acetylsulfamerazine, $N^4$-acetylsulfamethazine, $N^4$-acetylsulfamethoxazole, sulfamethoxazole-$N^1$-glucuronide) in environmental samples. The solid phase extraction (SPE) with LC/ESI-MS/MS have been used for the analysis of target compounds, and the recoveries of SPE clean-up were at the range of 12-94% for C18 cartridge, 60-95% for HLB cartridge, 25-123% for MCX cartridge, and 70-90% for tandem HLB/MCX. By established method, detection limit, recovery, and relative standard deviation were 0.001~0.187 ng/mL, 66~115%, and 5~17%, respectively. This method was effective and sensitive to use for the simultaneous determination of sulfonamide antibiotics and their metabolites in environmental samples. Four sulfonamide antibiotics were detected at the range of 0.008~2.153 ng/mL. For metabolites, only $N^4$-acetylsulfamethoxazole was detected, but the concentration was under the MDL level.

Non Thermal Process and Quality Changes of Foxtail Millet Yakju by Micro Filtration (미세여과에 의한 비 가열살균 좁쌀약주의 제조 및 저장 중 품질변화)

  • Kang, Young-Joo;Oh, Young-Ju;Koh, Jeong-Sam
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.2
    • /
    • pp.277-284
    • /
    • 2005
  • Micro-filtration (MF) or ultra-filtration (UF) system with hollow-fiber cartridge was introduced in order to improve the Quality level of commercial foxtail millet Yakju, which has an off-flavour and/or undesired colour after the thermal treatment. The filtration effects of cartridges such as MF (0.65, 0.45, 0.2, 0.1 $\mu$m) and UF (500 K dalton) were investigated. The physicochemical and sensory characteristics of the Yakju were then evaluated during the 6 months storage at room temperature. The exclusion ability of microorganism in samples was confirmed in all cartridges, but 0.45 pm MF-cartridge was suitable in the Yakju manufacture due to its superior filtration rate and efficiency. Changes in reducing sugar and colour difference of foxtail millet Yakju untreated or treated by heat ($65^{\circ}C$${\times}$10 min) were observed during the storage; after 6 months the L-value of thermal-treatment sample was decreased and its b-value, however, significantly increased so that its color became dark, in comparison to non-thermal treatment sample. This decrease of reducing sugar is assumed that color change is associated with non-enzymatic browning reaction. Sensory Quality of foxtail millet Yakju produced by non-thermal treatment was better than that of thermal treatment.

Rapid Preparation and Quality Control of $^{99m}Tc$-ECD, $MAG_3$ and MIBI using Microwave Heating and Sep-Pak Cartridges (마이크로웨이브와 Sep-Pak 카트리지를 이용한 $^{99m}Tc$-ECD, $MAG_3$, MIBI의 신속한 제조 및 정도관리)

  • Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.430-438
    • /
    • 1999
  • Purpose: We evaluated a rapid preparation procedures for the labeling and quality control of $^{99m}Tc$-ECD, $MAG_3$, and MIBI using microwave heating and Sep-Pak cartridges. Materials and Methods: $^{99m}Tc$ labeling of ECD, $MAG_3$, and MIBI kit preparation was performed according to the package inserts with microwave heating modification. Heating time was 10-15 sec, and heating was performed with 3 mm plastic bottle with screw cap to prevent radiation contamination. Labeling efficiency was obtained with $C_{18}$ or Alumina N Sep-Pak cartridges. Results: The radiochemical purity of $93{\sim}96%$ for $^{99m}Tc$-ECD and $95{\sim}99%$ for $^{99m}Tc$-MIBI was obtained using Alumina N Sep-Pak cartridge. The optimum irradiation time of microwave method for 3 ml $^{99m}Tc$-labeled radiopharmaceutical solution was 10 sec for $^{99m}Tc$-ECD and $^{99m}Tc$-MIBI, and 15 sec for $^{99m}Tc-MAG_3$. The results of quality control data with Sep-Pak cartridges were well correlated with TLC method. The total preparation time of these radiopharmcaeuticals was $5{\sim}6min$ including quality control procedure. Conclusion: This study demonstrates that radiopharmaceuticals preparation by microwave heating and quality control by Sep-Pak cartridges can be efficiently utilized as an alternative to the recommended method by manufacturer's manual.

  • PDF

Photocatalytic Treatment of Waste Air Containing Malodor and VOC by Photocatalytic Reactor Equipped with the Cartridges Containing the Media Carrying Photocatalyst (광촉매 카트리지를 활용한 악취 및 VOC를 함유한 폐가스의 광촉매처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.80-86
    • /
    • 2013
  • In this study, the photocatalytic reactor system equipped with photocatalyst-carrying-silica-media cartridges [photocatalytic reactor system (1)] was used to perform the treatment of waste air containing malodor and volatile organic compound (VOC). The result of its performance was evaluated and compared with that of the photocatalytic reactor system equipped with commercial photocatalyst-carrying-nonwoven filter-media cartridges [photocatalytic reactor system (2)]. In case of photocatalytic reactor system (1), at the 1st stage of run the removal efficiencies of ethanol and toluene continued to be 80% and 20%, respectively. However, unlike toluene, the removal efficiency of ethanol dropped to 40% at the end of the 1st stage of run. The removal efficiency of hydrogen sulfide decreased from 100% to 90%. At the 2nd stage of its run the removal efficiency of ethanol decreased to 10% while the removal efficiencies of hydrogen sulfide and toluene remained as same as 90% and 20%, respectively, even though the inlet load of toluene increased by factor of four. In the 3rd stage of its run, as the result of application of aluminium-coated reflector film to the inner wall of photocatalytic reactor system, the removal efficiencies of ethanol and toluene increased by 5% to be 15% and 25%, respectively. In case of photocatalytic reactor system (2), at the 1st stage of its run, the removal efficiencies of ethanol, hydrogen sulfide and toluene continued to be 10%, 97% and 100%, respectively. However, at 2nd stage of its run their removal efficiencies became 5%, 95% and 2~3%, respectively, which showed that the removal efficiencies of ethanol and hydrogen sulfide decreased insignificantly while the removal efficiency of toluene dropped significantly from the perfect elimination. Moreover, the reflector film did not affect the performance of photocatalytic reactor system (2) at all. Therefore the removal of ethanol, hydrogen sulfide and toluene by photocatalytic reactor system (2) was mainly attributed to hydrophobic adsorption of its nonwoven filter media and its extent of photocatalytic removal turned out to be negligible, compared to that of photocatalytic reactor system (1).

Effects of Pleating Parameters on Characteristics of Cylindrical Cartridge Air Filters (원통형 카트리지 에어 필터(cartridge Air filters)의 절곡 변수에 따른 집진 성능 변화)

  • Park, H.S.;Park, S.J.;Kim,, S.D.;Choi, H.K.;Lim, J.H.;Park, Y.O.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.154-157
    • /
    • 2001
  • The effects of pleating parameters on the performance of cylindrical cartridge air filters was experimentally studied. The tested filters are 150 mm in outer diameter and 700 mm in length. As the pleat count increases, the pressure drop across a cartridge filter is decreased for a constant pleat depth and flow rate. This is due to the increased filtration area which brings out less pressure loss of the filter. However, in the case of the filters having the pleat depth of 40 mm, the inner diameter of the cartridges is so small that the pressure loss is greatly increased.

  • PDF