• Title/Summary/Keyword: 카메라 자가 보정

Search Result 28, Processing Time 0.022 seconds

Optical Implementation of Single Layer Neural Networks Using Diffraction Grating (회절격자를 이용한 광학적 단층 인식자의 구현)

  • 이재명;박성균;임종태;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.10
    • /
    • pp.934-940
    • /
    • 1991
  • A modified quantizing method is introduced to teach single layer learning algorithm, which is implemented optically. The proposed optical system consists of input masks, holographic diffraction grating. LCD and CCD camera. The 2 dimensional interconnections between input neurons and output neurons are realized using holographic phase grating, which is fabricated for equal intensity distribution of diffraction orders. The two gray levels of LCD act as binary weights for each interconnection. The weights are compensated according to the learning algorithm in which the amount of weights to be compensated is determined by comparing the output patterns with target patterns. The learning process is iterated until the predetermined conditions are satisfied. Optical experiments are performed for two learning rates, 0.5 and 0.9 and the experimental results show that the proposed system is useful for optical neural networks.

  • PDF

A Study on the High-Speed Extraction of Bar Code ROI based on the CCD (CCD 기반 바코드 관심대상영역 고속 추출에 관한 연구)

  • Park, Moon-Sung;Choi, Ho-Seok;Kim, Jin-Suk;Kim, Hea-Kyu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.04b
    • /
    • pp.1103-1106
    • /
    • 2002
  • 현재, 컨베이어 벨트시스템에 소포를 직재하고, 우편번호를 운영자가 입력하여 구분한다. 구분된 소포 중에서 기록관리 대상의 경우에는 바코드를 판독하여 처리하고 있다. 이에 따라, 본 논문에서는 2m/sec 이내로 이송되는 소포를 라인 CCD(Charged Coupled Device) 카메라에 의해 이미지 획득한 후, 바코드 ROI 추출 방법을 위해 $32{\times}32$ 미세블룩 검사 방법을 적용하였다. ROI 추출 절차는 최대-최소 차이값과 동적 인계값 기준으로 바탕면 제거, 문자열과 바코드 영역을 판단하기 위한 대각선(diagonal) 검사방법 적용, 바코드 영역인지 검증하기 위해 수평으로 5 라인을 검사하고 에지의 수와 폭의 변화량 비교 등의 과정으로 수행하였다. 그리고 바코드 ROI 추출은 레이블링 과정에 의해 바코드 영역의 보정과 그룹크기 비교에 의한 ROI 영역의 구체화와 정보 해석을 위하여 ROI 외곽좌표 8개중에서 가장 간 중심축 라인으로 생성하는 방법 등을 적용하였다. ROI 추출과 중심축 시험결과에 의하면 $50{\sim}180msec$이내에 가능하게 되었다. 그리고, ROI 추출의 정확도는 99.994% 이상을 만족한다.

  • PDF

Development of Float Water Level Meter Portable Calibration System (부자식 수위계 이동형 교정시스템 개발)

  • Hong, Sung-taek;Kim, Il-han;Choi, Jong-woong;Shin, Gang-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.411-414
    • /
    • 2016
  • K-water institute is a calibration and test institute accredited by international standard calibration center for water-level meters. Due to the absence of on-site calibration system and procedure for Float Water Level Meter, the calibration was performed only in the standard calibration laboratory. In this study, mobile calibration system and procedure were developed to calibrate Float Water Level Meter on site using scale bar and camera. It is possible to obtain reliable water-level data and achieve consistent data management.

  • PDF

Annotation System using Spatial Augmented Reality Display with Half-slivered Mirror (반투영 거울 기반 공간 증강 현실 환경의 전시물 안내 시스템)

  • Kim, Jung-Hoon;Lee, Young-Bo;Park, Hyun-Woo;Yun, Tae-Soo;Lee, Dong-Hoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.13 no.1
    • /
    • pp.37-45
    • /
    • 2008
  • This paper proposes a half-silvered mirror display system designed to demonstrate useful information about things on display into the air. It helps the spectators gain quick access to information near the area where the things are put on display. This paper deals with three matters: First, tracking based on camera images created in real time enables the provision of information about the things that are both still and moving. Second, as information is output based on the real-time coordinates of things on display, the parallel processing-based tracking algorithm is used to ensure smooth transfer. Third, a half-mirror is placed in front of the display area to establish an augmented reality system and visual distortion caused by mirror angle is adjusted by the reflection transformation matrix. The objectives of this system are to arouse the spectators' interest in things on display and offer easy and quick access to information about them.

  • PDF

Detection Range Improvement of Radiation Sensor for Radiation Contamination Distribution Imaging (방사선 오염분포 영상화를 위한 방사선 센서의 탐지 범위 개선에 관한 연구)

  • Song, Keun-Young;Hwang, Young-Gwan;Lee, Nam-Ho;Na, Jun-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1535-1541
    • /
    • 2019
  • To carry out safe and rapid decontamination in radiological accident areas, acquisition of various information on radiation sources is needed. In particular, to figure out the location and distribution of radiation sources is essential for rapid follow-up and removal of contaminants as well as minimizing worker damage. The radiation distribution detection device is used to obtain the position and distribution information of the radiation source. In the case of a radiation distribution detection device, a detection sensor unit is generally composed of a single sensor, and the detection range is limited due to the physical characteristics of the single sensor. We applied a calibration detector for controlling the detection sensitivity of a single sensor for radiation detection and improved the limited detection range of radiation dose rate. Also, gamma irradiation test confirmed the improvement of radiation distribution detection range.

Enhanced Weighted Directional Demosaicking using Edge Indicator (에지 지시자를 이용한 향상된 방향 가중치 디모자이킹 알고리듬)

  • Ryu, Ji-Man;Yang, Si-Young;Lim, Tae-Hwan;Jung, Je-Chang
    • Journal of Broadcast Engineering
    • /
    • v.15 no.2
    • /
    • pp.265-279
    • /
    • 2010
  • A color image requires at least three color channels to obtain the full color image. However the image sensor obtains only the intensity of the brightness, that is, three image sensors are required for every pixel to capture the full color image. Since the image sensor is quiet expensive, most of digital still cameras adopt single image sensor array with color filter array (CFA) to reduce the size and the cost. Since the image obtained using single sensor array has only one color component per pixel, we need to reconstruct the missing two color components to obtain the full color image. We call this process as color filter interpolation or demosaicking. In this paper, demosaicking algorithm composed of two large step is proposed. Proposed algorithm is combined with several different algorithms such as Edge-directed demosaicking, Second-order gradients as correction terms, Smooth hue transition Interpolation, etc. The simulation results show that the proposed algorithm performs much better than the state-of-the-art demosaicking algorithms in terms of both subjective and objective qualities.

A Study on Development of Portable Concrete Crack Measurement Device Using Image Processing Technique and Laser Sensors (이미지 처리기법 및 레이저 센서를 이용한 휴대용 콘크리트 균열 측정 장치 개발에 관한 연구)

  • Seo, Seunghwan;Ohn, Syng-Yup;Kim, Dong-Hyun;Kwak, Kiseok;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.41-50
    • /
    • 2020
  • Since cracks in concrete structures expedite corrosion of reinforced concrete over a long period of time, regular on-site inspections are essential to ensure structural usability and prevent degradation. Most of the safety inspections of facilities rely on visual inspection with naked eye, so cost and time consuming are severe, and the reliability of results differs depending on the inspector. In this study, a portable measuring device that can be used for safety diagnosis and maintenance was developed as a device that measures the width and length of concrete cracks through image analysis of cracks photographed with a camera. This device captures the cracks found within a close distance (3 m), and accurately calculates the unit pixel size by laser distance measurement, and automatically calculates the crack length and width with the image processing algorithm developed in this study. In measurement results using the crack image applied to the experiment, the measurement of the length of a 0.3 mm crack within a distance of 3 m was possible with a range of about 10% error. The crack width showed a tendency to be overestimated by detecting surrounding pixels due to vibration and blurring effect during the binarization process, but it could be effectively corrected by applying the crack width reduction function.

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF