• Title/Summary/Keyword: 침전 진단

Search Result 35, Processing Time 0.027 seconds

A Study on Analysis of Influx Path and Ingredient of Sedimentation Substance in Tunnel Drainage System (터널 배수시설에 유입된 침전물의 유입경로 및 성분분석 연구)

  • Woo, Jong-Tae;Yoo, Sang-Geon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.145-152
    • /
    • 2004
  • Red sedimentation substance contains large portion of Fe. The earth retaining structure of a tunnel and ground water containing more portion of Fe than other area are the major factor of this substance In case of white sedimentation substance, the most frequently founded ingredient is CaO, which is occurred in case grouting injection materials for ground reinforcement is transmitted into a tunnel system by ground water. This substance is doesn't affect safety of a tunnel Black sedimentation substance is often found in tunnels near station. This substance is a mixture of either white or red sedimentation substance and detergent material in station transmitted to a tunnel drainage system.

Development of SV30 Detection Algorithm and Turbidity Assumption Model using Image Analysis Method (이미지 분석기법을 이용한 SV30 자동감지방법 및 탁도 추정 모델 개발)

  • Choi, Soo-Jung;Kim, Ye-Jin;Yoom, Hoon-Sik;Cha, Jae-Hwan;Choi, Jae-Hoon;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.168-174
    • /
    • 2008
  • Diagnosis on setteability based on human operator's experimental knowledge, which could be established by long term operation, is a limit factor to construction of automation control system in wastewater treatment plant. On-line SVI(Sludge Volume Index) analyzer was developed which can measure SV30 automatically by image capture and image analysis method. In this paper, information got by settling process was studied using On-line SVI analyzer for better operation & management of WWTPs. First, SV30 detection algorithm was developed using image capture and image analysis for settling test and it showed that automatic detection is feasible even if deflocculation and bulking was occurred. Second, turbidity assessment model was developed using image analysis.

간헐식 폭기에의한 활성슬러지의 활성 모니터링

  • Park, Sun-Eung;Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.558-559
    • /
    • 2001
  • 생물학적 폐수처리 (biological treatment)의 슬러지의 활성도 측정을 위하여 슬러지의 대사 열을 측정하는 장치와 소프트웨어를 개발하였다. 슬러지의 활성을 측정하는 호흡계와 같이 간헐식으로 폭기와 침전을 반복하연서 슬러지의 대사열의 monitoring 을 통하여 슬러지의 활 성진단올 할 수 있었다.

  • PDF

Evaluation of analytical method for polybrominated diphenyl ethers (PBDEs) in manufactured products waste (제품폐기물 중 폴리브롬화에테르류 (PBDEs) 분석방법 비교 연구)

  • Shin, Sun Kyoung;Kim, Hyoung Seop;Jeon, Tae Wan;Kim, Tae Seung;Kim, Jong Ha;Lee, Jeong Ah
    • Analytical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.109-114
    • /
    • 2007
  • In this study, soxhlet extraction and dissolution-precipitation method are used for separating analyte from polymer materials. In soxhlet extraction efficiency test, it has been found that the DCM, Toluene, THF, and mixtures Acetone/Hexane (1:4, v/v) gave good extraction efficiency, while the use of the ethyl ether, acetone/ethyl ether (1:4, v/v), acetone/hexane (1:1, v/v), DCM/hexane (1:1, v/v) resulted in significantly lower values. In case of dissolution-precipitation method, there is no considerable difference with used different dissolving solvent. The elution amount of multi layer silica and Florisil column were determined with hexane 250 mL and 70 mL of hexane, respectively. Range of PBDE in real waste plastics was N.D.~1,028 ppm.

Detection of Cucumber green mottle mosaic virus in Bottle Gourd Seeds by RT-PCR (RT-PCR에 의한 박 종자의 오이녹반모자이크바이러스 검정)

  • Lee, Sook-Kyung;Song, Wan-Yeob;Kim, Hyung-Moo
    • Research in Plant Disease
    • /
    • v.10 no.1
    • /
    • pp.53-57
    • /
    • 2004
  • Cucumber green mottle mosaic virus (CGMMV) was a major pathogen of watermelon and had affected seriously to watermelon production in Korea. Rapid and sensitive detection method of CGMMV associated with bottle gourd (Lagenafia siceraria) seeds was developed by using RT-PCR in this study. A pair of primeri Wmfl and Wmrl, specific for CGMMV was designed from coat protein gene sequences of CGMMV-W and used for amplifying 420 bp product in RT-PCR. To simplify the virus extraction procedure and reduce an inhibitor from the extract for the RT-PCR, some methods using ethanol precipitation, double filtration, polyethylene glycol precipitation and phenol/chloroform/isoamyl alcohol extraction procedure were compared and the phenol/chloroform/isoamyl alcohol extraction procedure was selected by its enhanced sensitivity. This detection method using the selected extraction step and the primers for RT-PCR could reliably detect an infected level of one CGMMV-infested seed in 1,000 seeds. This rapid and sensitive RT-PCR assay provides auseful tool for the specific detection of CGMMV in bottle gourd seed samples containing high levels of back-ground inhibitors.

Comparison of WBCs and RBCs Concordance between the Cobas u 701 Analyzer and Three Manual Microscopy Methods in Urine Sediment (소변 침전물에서 Cobas u 701 Analyzer와 세 가지 수동 현미경검사법의 백혈구와 적혈구의 일치도 비교)

  • Hyeok-Jae LEE;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.82-92
    • /
    • 2023
  • Urine sediments are performed by a microscopic examination of centrifuged urine by medical technologists. This study examined different urine sediment preparation procedures. The 107 fresh urine specimens that tested positive from white blood cells (WBCs) and red blood cells (RBCs) in the urine dipstick test and the cobas u 701 analyzer, respectively, were selected for manual microscopy. This study evaluated an automated urine sediment analyzer and three manual microscopy methods for WBCs and RBCs. The methods were performed according to the test guidelines. The coefficients of determination between the cobas u 701 analyzer and the Korean Association of Quality Assurance for Clinical Laboratory (KAQACL) for WBCs and RBCs were r2=0.977 and r2=0.970, respectively. The concordance rates between the cobas u 701 analyzer and KAQACL for WBCs and RBCs were 74.8% and 77.6%, respectively. A good correlation and concordance with the automatic analyzer were shown when the specimens were prepared and examined using the KAQACL method. Consequently, the differences in the urine sediment preparation procedures affected the sediment concentrations, influencing the cell number per high power field (HPF).

Detection of Macro-Aspartate Aminotransferase (AST) in an Asymptomatic Patient with Persistent Elevation of AST (지속적으로 AST가 증가된 무증상 환자에서 Macro-AST의 검출)

  • Yang, Eun Ju;Lim, Sung Soo;Shin, Kyeong Seob
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.2
    • /
    • pp.188-192
    • /
    • 2021
  • The persistent increase of aspartate aminotransferase (AST) due to the presence of a macro-AST can confuse diagnostic or therapeutic decisions in many clinical situations. In this study, we report a case of isolated and persistent AST-elevation without any clinical sign of dysfunction in organs such as the liver, skeletal muscle, cardiac muscle, etc. Despite various investigations, no definite cause for the elevation of AST could be found. With the help of polyethylene glycol (PEG) precipitation, we showed that macro-AST formation was responsible for the elevation of the AST titer in this case. Early recognition of macro-AST by PEG precipitation can prevent diagnostic confusion and unnecessary and even invasive tests.

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Study on the Difference of Urine Sediment Preparation for Microscopic Examination (현미경검사를 위한 요침사 표본제작에 따른 차이 연구)

  • Lee, Hyeok-Jae;Park, Chul;Seo, Min-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.366-373
    • /
    • 2017
  • Urinalysis is considered to be easier and simpler than other tests. It has been known to cause no burden to patients, while offering important information on diagnosing, treating, and determining the prognoses of kidney and urinary tract diseases. Urinary sediments are usually performed by microscopic examination of centrifuged urine by technologist. The guidelines proposed by the Korean Association of External Quality Assessment Service are actually different from those actually practiced by medical institutions and taught to biomedical students in textbooks. Therefore, we verified whether different sediment preparation methods lead different test results. Specimens that tested positive from the occult blood and leukocyte esterase in the urine dipstick test were randomly selected for a microscopic examination. The differences in the urine sediment preparation affected the sediment concentrations, which influenced the cell grade and cell number per HPF. The first factor in determining the sediment concentration is the centrifugal force. Many medical institutions use 1,500 rpm as the centrifugal speed without considering the radius of the centrifuge; such a value may not be accurate for 400 G. Consequently, there were differences in urine concentrations, which influenced the results. The second factor is the amount of sediment in urine. Different amounts of the remaining supernatant led to different sediment concentration factors, again, causing different results. Furthermore, not only by using a pipette to obtain an accurate amount as stipulated, but also by roughly obtaining a drop, the microscopic examination using such a volume of sediment examined affected the results. Therefore, this study highlights the importance of standardization of urine sediment preparation procedures to promote consistency and accuracy across institutions.

Petrological and Geological Safety Diagnosis of Multi-storied Stone Pagoda in the Daewonsa Temple, Sancheong, Korea (대원사 다층석탑의 지질학적 및 암석학적 안전진단)

  • 이찬희;서만철
    • Economic and Environmental Geology
    • /
    • v.35 no.4
    • /
    • pp.355-368
    • /
    • 2002
  • The multi-storied Daewonsa stone pagoda (Treasure No. 1112) in the Sancheong, Korea was studied on the basis of deterioration and geological safety diagnosis. The stone pagoda is composed mainly of granitic gneiss, partly fine-grained granitic gneiss, leucocratic gneiss, biotite granite and ceramics. Each rock of the pagoda is highly exfoliated and fractured along the edges. Some fractures in the main body and roof stones are treated by cement mortar. This pagoda is strongly covered with yellowish to reddish brown tarnish due to the amorphous precipitates of iron hydroxides. Dark grey crust by manganese hydroxides occur Partly, and some Part coated with white grey gypsum and calcite aggregates from the reaction of cement mortar and rain. As the main body, roof and upper part of the pagoda, the rocks are developed into the radial and linear cracks. Surface of this pagoda shows partly yellowish brown, blue and green patchs because of contamination by algae, lichen, moss and bracken. Besides, wall-rocks of the Daewonsa temple and rock aggregates in the Daewonsa valley are changed reddish brown color with the same as those of the pagoda color. It suggests that the rocks around the Daewonsa temple are highly in iron and manganese concentrations compared with the normal granitic gneiss which color change is natural phenomena owing to the oxidation reaction by rain or surface water with rocks. Therefore, for the attenuation of secondary contamination, whitening and reddishness, the possible conservation treatments are needed. Consisting rocks of the pagoda would be epoxy to reinforce the fracture systems for the structural stability on the basements.