• Title/Summary/Keyword: 치조골 교체

Search Result 3, Processing Time 0.017 seconds

The effects of pregnancy on alveolar bone turnover during experimental tooth movement in rats (백서에서 실험적 치아이동시 임신이 치조골 교체(Turnover)에 미치는 영향에 대한 연구)

  • Kim, Young-Sun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.4 s.81
    • /
    • pp.413-421
    • /
    • 2000
  • The purpose of this study was to observe the effects of pregnancy on the experimental tooth movement and alveolar bone turnover process of Sprague-Dawley female rat. Sixty rats were divided into pregnant-tooth movement group(P-Tm), normal-tooth movement group(N-Tm) and normal group(N). Maxillary first molar appliances were inserted bilaterally and activated to 40grams. To measure the amount of tooth movement, x-ray was taken 2 times after appliance insertion and before sacrifice. Animals were sacrificed at 1,3,7,14 days(N=5). Just after sacrifice, alveolar bones were collected and frozen immediately for biochemical analysis. Tooth movement was assessed cephalometrically and tartrate-resistant acid(TRAP) and alkaline phosphatase (ALP) activities were measured in extracts of paradental alveolar bone. The results were as follows: 1. The amount of tooth movement in P-Tm group was greater than that of N-Tm group(p<0.01). 2. Alveolar bone ALP of normal tooth movement group was not significantly different from the control, TRAP was significantly different from the control(p<0.01). In normal tooth movement group, alveolar bone ALP was increased gradually and peak(day 7) fell off significantly at day 14(p<0.05). The Peak of alveolar bone TRAP(day 7) fell off slightly, sustained day 14(p<0.01). 3. Alveolar bone ALP and TRAP of pregnant tooth movement group were not significantly different from that of normal tooth movement group. In pregnant tooth movement group, alveolar bone ALP was increased at day 3(p<0.01) and fell off significantly at day 7-14, alveolar bone TRAP were increased at day 3 and sustained day 14. 4. The peak of alveolar bone phosphatases in pregnant tooth movement group(day3) preceded the peak in normal tooth movement group(day7) (p<0.01). According to the above results, we suggested that bone resorption activity was increased in alveolar bone of pregnant rat, and the degree of tooth movement in pregnancy may be greater than that of normal group because of high bone turnover of alveolar bone in pregnant rat.

  • PDF

Alveolar bone turnover during experimental tooth movement in Streptozotocin-induced diabetic rat (스트렙토조토신 유발 당뇨병 백서에서 실험적 치아이동중의 치조골 교체)

  • Lee, Ki-Soo;Lee, Taek-Woo;Kim, Sung-Jin
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.357-367
    • /
    • 2001
  • The purpose of this study was to investigate the alveolar bone turnover in diabetic rat, and to compare the alveolar bone turnover during tooth movement in diabetes with that in normal control Eighty Male Sprague-Dawley strain rats(8th week) were divided into normal control(N), normal-tooth movement (N-tm), diabetes(D), and diabetes-tooth movement(D-tm) groups. Eighteen days before the start of the experiment, diabetes was induced with a single injection of streptozotocin 50 mg/kg of body weight in citrate buffer as vehicle via the tail vein. Maxillary first molars of rats were moved mesially by 40 grams of the closed coil spring. Experimental animals were sacrificed after 1d, 3d, 7d, and 14d experimental period, and the alveolar bone around the maxillary first molars were assayed biochemically for acid phsophatase(ACP) and tartrate-resistant acid phosphatase (TRAP) as bone resorption markers, and alkaline phosphatase(ALP) and osteocalcin(OC) as bone formation markers. TRAP and OC concentration in serum and alveolar bone of D group were lower than those in N group, and especially OC concentration decreased mote following diabetes prolonged, which showed the decreased skeletal and alveolar bone resorption and formation potential in diabetic rats. In N-tm group compared with N group, alveolar bone ACP and TRAP concentrations were highest at 1d and 3d(p<0.01), decreased after then, and showed lowest at 14d, and alveolar bone OC concentration was higher at 3d, 7d, and 14d(p<0.001) and showed a tendency of peak level at 7d. which showed the peak of concentration of bone resorption markets at 1d-3d and those of bone formation markers at 7d. In D-tm group compared with N group, alveolar bone ACP and TRAP concentrations were higher at 3d, 7d and 14d(p<0.001), and tended to reach peak value at 7d and persisted through 14d, and alveolar bone ALP and OC concentration increased but not different from that of N group. The amount of tooth movement in D group were greater than that of N group at all experimental period. Those results were suggested that during diabetes, the alveolar and skeletal bone undergo low bone turnover and the mote amount of tooth movement, hut because the peak time of alveolar bone resorption activity was delayed and sustained in longer period of tooth movement and alveolar bone formation activity is lower than that of normal tooth movement, the periodontal space is supposed to be larger doting tooth movement.

  • PDF

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.