• Title/Summary/Keyword: 치의학

Search Result 1,027, Processing Time 0.026 seconds

Data resource profile: oral examination of the Korea National Health and Nutrition Examination Survey (국민건강영양조사 구강검사 개요)

  • Woo, Gyeong-Ji;Lee, Hye-Rin;Kim, Yoonjung;Kim, Hye-Jin;Park, Deok-Young;Kim, Jin-Bom;Oh, Kyung-Won;Choi, Youn-Hee
    • Journal of Korean Academy of Oral Health
    • /
    • v.42 no.4
    • /
    • pp.101-108
    • /
    • 2018
  • Objectives: The Korea National Health and Nutrition Examination Survey (KNHANES) is a national surveillance system that has been assessing the health and nutritional status of Koreans since 1998. Based on the National Health Promotion Act, the surveys have been conducted by the Korea Centers for Disease Control and Prevention (KCDC). Methods: An oral examination as part of The National Health and Nutrition Examination was proposed to calculate the sample design and survey participation. The surveying system was presented by classifying the measurement environment, screening, and survey items by year, and the merits and limitations of using the data were suggested by examining the status of survey quality management and the process of disclosing raw data. Results: This nationally representative cross-sectional survey samples approximately 10,000 individuals each year and collects information on oral examinations and oral health interviews. Data for the oral health component of KNHANES was obtained to assess the oral health status of Koreans and determine the prevalence of dental caries and periodontitis. The oral health data quality control of KNHANES was composed of three parts: "Education Program" and "Field Training Program" for quality control of oral health examiners (dentists) by the professional academy, and "Data management" by the KCDC. After completion of the three-step data check, the indicators of dental caries, periodontal disease, and oral health behavior were published in the National Health Statistics. Conclusions: To achieve the goals of oral health indicators, we will continue to monitor so that we can use it as basic data for oral policies and carry out various linkage analyses related to oral diseases.

Evaluation of the dimensional change of 3D-printed complete denture after post-curing (후경화에 따른 3차원 프린팅 의치의 체적변화)

  • Suyeon, Lee;Younghun, Kwak;Eunchul, Park;Heejung, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.233-241
    • /
    • 2022
  • Purpose: The purpose of this study was to assess the dimensional change of 3D-printed dentures after post-curing. Materials and Methods: The upper and lower dentures were designed in Exocad DentalCAD software and exported as STL files. The upper and lower dentures were printed from 10 STL files using a DLP-type dental 3D printer. The printed upper and lower dentures were cleaned, and a scan file was created using a model scanner before and after post-curing. The dimensional change was evaluated by superimposing the scanned denture files before and after post-curing and measuring the distance between measurement points on the denture. SPSS was used for statistics, and the level of significance was 5%. Results: The maxillary denture reduced in size during post-curing, with the most notable color change occurring in the posterior palatal region. The reduction in anteroposterior maxillary denture length (A-D, A-E, A-F), as well as the distance between the first molars on both sides (B-C), was statistically significant. After post-curing, the mandibular denture showed more noticeable color change in the posteriorly buccal and lingual region. The decrease of length on the posterior (A-M, A-D, A-E, A-L, A-H, A-I, H-I) and lingual (J-K, L-M) sides of the denture were statistically significant. Conclusion: There was significant dimensional change in both the length and width of the 3D-printed maxillary and mandibular dentures after post-curing in this experiment. Consequently, it is seemed necessary to develop post-curing techniques and materials that reduce such denture deformation.

Factors Influencing Upper Airway Dimensions in Skeletal Class II Children and Adolescents: A CBCT Study (골격성 II급 소아·청소년의 상기도 공간에 영향을 미치는 요인 : CBCT 연구)

  • Kim, Byounghwa;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to investigate factors influencing the upper airway dimensions in skeletal Class II children and adolescents. In total, 67 patients were selected. Airway volume and minimal cross-sectional area were three-dimensionally assessed. Craniofacial morphology and skeletal maturity were assessed on generated two-dimensional cephalograms. The measurements were analyzed using Mann-Whitney test, one-way ANOVA, Pearson's correlation, and multiple regression analysis. Upper airway dimensions were significantly smaller in pre-peak stage group, and positively associated with age. Anterior facial height and age were the most relevant factors for airway volume. Mandibular width and age were the most relevant factors for minimal cross-sectional area. Upper airway dimensions were significantly associated with age, skeletal maturity and craniofacial morphology in all three planes.

Fixed implant rehabilitation of maxillary edentulous patient using intraoral scanning digital workflow: a case report (상악 완전 무치악 환자에서 구강 스캐닝 디지털 워크플로우를 활용한 완전 고정성 임플란트 수복 증례)

  • Seung Min Park;YoungBum Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.38-46
    • /
    • 2024
  • In order to treat edentulous patients with fixed implant prosthesis, the final prosthesis form should be predetermined based on the anatomic structures of the arch, the opposing dentition, and the occlusal plane. The design and occlusion of the interim prosthesis can provide useful information when fabricating the definitive prosthesis. In this case report, scan data of the edentulous region and the interim prosthesis were superimposed through an intraoral scanning digital workflow. In this way, the interim prosthesis information was incorporated into the design of the final prosthesis. Furthermore, the interim prosthesis data acquired through intraoral scanning was utilized to plan the positions and angles of the implants based on the final prosthesis design. Surgical guides were used to accurately place the implants in the planned three-dimensional positions. In this case report, satisfactory esthetic and functional clinical outcomes were achieved through application of digital techniques.

Questionnaire survey for the clinical trial participants who experienced both digital and conventional impression (디지털 인상법과 종래인상법을 동시에 경험한 임상시험자를 대상으로 한 설문지분석)

  • Yang, Eunbee;Kim, Bongju;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.270-279
    • /
    • 2018
  • Purpose: The aim of this study was to assess the patients' perception, acceptance, and preference of the difference between a conventional impression and digital impression through questionnaire survey. Materials and Methods: Thirteen (6 male, 7 female) subjects who experienced both digital and conventional impression at the same day were enrolled in this study. Conventional impression were taken with polyvinylsiloxane and digital impression were performed using a newly developed intra-oral scanner. Immediately after the two impressions were made, a survey was conducted with the standardized questionnaires consisting of the following three categories; 1) general dental treatment 2) satisfaction of conventional impression 3) satisfaction of digital impression. The perceived source of satisfaction was evaluated using Likert scale. The distribution of the answers was assessed by percentages and statistical analyses were performed with the paired t-test, and P < 0.05 was considered significant. Results: There were significant differences of the overall satisfaction between two impression methods (P < 0.05). Digital impression showed high satisfaction in less shortness of breath and odor to participants compared to conventional impression. The use of an oral scanner resulted in a discomfort of TMJ due to prolonged mouth opening and in lower score of the scanner tip size. Conclusion: It was confirmed that the preference for the digital impression using intraoral scanner is higher than the conventional impression. Most survey participants said they would recommend the digital impression to others and said they preferred it for future prosthetic treatment.

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

THE SPONTANEOUS ERUPTION OF DISPLACED PERMANENT TOOTH BY PERIAPICAL LESION OF PRIMARY TEETH (유치의 치근단 병소에 의해 변위된 영구치의 자발적 맹출)

  • Kang, Dong-Gyun;Yang, Seung-Duck;Kim, Tae-Wan;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.329-334
    • /
    • 2007
  • The infection of primary teeth occurs by caries or trauma. But, if it is not treated on time, the complication may occur such as enamel hypoplasia, discoloration, impaction, displacement and dilaceration of permanent successors. The periapical lesion on primary tooth could displace the permanent successors in any direction. Treatment options of displaced tooth are observation after extracting the primary teeth, surgical exposure orthodontic traction, transplantation and extraction. In these cases, displacement of permanent central incisor caused by the periapical lesion of primary teeth was observed. The spontaneous eruption after extraction of primary teeth was expected considering degree of displacement, development of root and direction of eruption. This case report shows spontaneous eruption of displaced permanent tooth germ was achieved with periodic examination after extraction of primary teeth.

  • PDF

IATROGENIC IMPACTION OF LOWER LEFT PERMANENT CANINE : CASE REPORT (하악 영구 견치의 의원성 매복에 대한 증례 보고)

  • Kim, Song-Yi;Choi, Sung-Chul;Choi, Yeong-Chul;Park, Jae-Hong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.339-344
    • /
    • 2008
  • When a delayed eruption of tooth is diagnosed, the causative factor should be detected before an establishment of treatment plan, if possible. Although a panoramic radiograph is enough to evaluate the position of tooth and the stage of tooth development, a 3-D Dental CT would be a powerful tool to reveal a spatial relationships between objects. The reported case showed a delayed eruption of lower left permanent canine and a mini-plate with screws adjacent to the impacted canine. Although the screws adjacent to the root of impacted tooth showed a close proximity, it was not presumed that these screws would interfere the eruption of the tooth. The impacted canine did not show any spontaneous eruption during observation. After the mini-plate and screws were removed, an orthodontic traction using elastic power chain was performed. The position of mini-plates and screws should be carefully designed to avoid damaging the tooth follicles or tooth roots in the jaw. Also the screws should be removed before an orthodontic traction to prevent damaging the root surface of impacted tooth.

  • PDF

A STUDY ON THE EFFECTS OF CENTRIC RELATION OCCLUSION-MAXIMUM INTERCUSPATION DISCREPANCIES TO DENTAL WEAR (중심위 교합-최대교두감합위 불일치가 치아 마모에 미치는 영향에 관한 연구)

  • Hong, Min-Ah;Kim, Kwang-Nam;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.683-700
    • /
    • 1998
  • 치아경조직의 소실은 반드시 치아우식증이나 사고에 의해서만 일어나는 것이 아니라 마모에 의해서도 일어난다. 마모에 영향을 미치는 인자들은 시간/나이, 성별, 이갈이와 같은 과기능, 저작력, 위장관장애, 음식물, 환경적인 영향, 타액의 상태 그리고 교합적인 조건들이 있다. 한편 중심위와 최대교두감합위 불일치가 악구강계에 미치는 영향에 관해서는 아직도 논란이 분분하다. 본 연구의 목적은 중심위와 최대교두감합위의 불일치가 치아마모에 미치는 영향과 중심위에서 제일 먼저 닿는 치아와 나머지 치아의 마모에 있어서 차이에 대해서 알아 보는 것이다. 본 연구는 두개하악관절과 저작습관에 이상이 없으며, 식이습관에 문제가 없으며 치아우식증과 치주질환, 수복물, 교정 또는 교합치료의 경험이 없는 21세에서 25세 사이의 서울대학교 치과대학생을 대상으로 하였다. 교합기를 이용하여 중심위 교합-최대교두교두감합위 불일치를 조사하여, 중심위 교합-최대교두감합위가 불일치가 작은 군과 큰 군으로 나누었다. 각 군은 각각 10명의 피검자들로 구성되었다. 각 피검자의 인상채득 후 CR mounting을 시행하고 중심위교합-최대감합위 불일치를 측정한 다음 임상검사로 ordinal scale을 측정하고 모형을 통해 arbitrary scale을 측정하였다. 평균치아마모도 그리고 중심위에서 먼저 닿는 치아와 나머지 치아, 나머지 구치의 마모도를 각각 조사하여 통계처리하였다. 1. 평균치아마모도는 ordinal scale로 측정하였을 때 중심위 교합-최대교두감합위 불일치가 작은 군과 큰 군 사이에 통계적으로 유의할만한 차이가 없었다(p>0.05) 2. 평균치아마모도는 arbitrary scale로 측정하였을 때 중심위 교합-최대교두감합위 불일치가 작은 군과 큰 군 사이에 통계적으로 유의할만한 차이가 없었다(p>0.05). 3. CR에서 먼저 닿는 치아와 나머지 치아, 나머지 구치의 마모도는 ordinal scale로 측정하였을 때 통계적으로 유의한 차이가 없었다(p>0.05). 4. CR에서 먼저 닿는 치아와 나머지 치아, 나머지 구치의 마모도는 arbitrary scale로 측정하였을 때 먼저 닿는 치아에서 통계적으로 유의한 높은 수준의 마모도를 보였다(p<0.05).

  • PDF

Effect of a Suspended Overhead Sprayer with Sector Formed Injection Nozzles on Spraying Uniformity (두상관수장치의 부채꼴분사노즐 설치위치가 살수균일성에 미치는 영향)

  • 김명규;정태상;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.4
    • /
    • pp.223-231
    • /
    • 1999
  • The one of basic functional conditions of suspended overhead sprayer, which is openly made use of irrigating on bedding plants in greenhouse, is to be kept the growing uniformity of bedding plants by making uniformly the spraying irrigation depending on the distribution of sprayed water. This study was performed to find out the optimum position of sector formed injection nozzle which is placed from the top of plant 0 the tip of the nozzle to keep spraying uniformity. The test of spraying distribution using a overhead sprayer, which was installed in a row of sector formed injection nozzles, was performed The measuring factor to represent spraying distribution was the water weight filled in each cup when the overhead sprayer was moving across the upside of the cups which were placed directly under the nozzles on keeping the distance from nozzle tip. The test results were as following , The standard mr of weights of each cup filled with spraying water was lower values at Position far from more than 60cm under nozzle tip. The driving speed variation of sprayer was not effected on spraying uniformity but the spraying water weight was inversely proportioned to the speed. To make best spraying uniformity, it was represented that the tip of the nozzle is positioned to keep the distance which the top of plants is placed at the second cross point of each injection sector of nozzles.

  • PDF