• Title/Summary/Keyword: 치수 온도변화

Search Result 74, Processing Time 0.029 seconds

Efficiency of ceramic bracket debonding with the Er:YAG laser (세라믹 브라켓의 제거 시 Er:YAG 레이저의 효능)

  • Suh, Chung-Hwan;Chang, Na-Young;Chae, Jong-Moon;Cho, Jin-Hyoung;Kim, Sang-Cheol;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.213-224
    • /
    • 2009
  • Objective: The aim of this study was to find out whether Er:YAG laser can aid in debonding ceramic brackets, and to see what kind of method will be the most appropriate for debonding. Methods: One hundred and ninety teeth, monocrystalline brackets ($MISO^{TM}$, HT, Ansan-Si, Korea), polycrystalline brackets ($Transcend^{TM}$ series 6000, 3M Untek, Monrovia, CA, USA) and the KEY Laser3 (KavoDental, Biberach, Germany) were used. Experimental groups were classified according to the type of ceramic brackets, and the amount of laser energy (0, 140, 300, 450, 600 mJ). After applying laser on the bracket at two points at 1 pulse each, the shear bond strength was measured. The effect of heat caused by laser was measured at the enamel beneath the bracket and pulp chamber. After measuring the shear bond strength, adhesive residue was evaluated and enamel surface was investigated using SEM. Results: All ceramic bracket groups showed a significant decrease in shear bond strength as the laser energy increased. The greatest average temperature change was $3.78^{\circ}C$ on the enamel beneath the bracket and $0.9^{\circ}C$ on the pulp chamber. Through SEM, crater shape holes caused by the laser was seen on the enamel and adhesive surfaces. Conclusions: If laser is applied on ceramic brackets for debonding, 300 - 450 mJ of laser energy will be safe and efficient for monocrystalline brackets ($MISO^{TM}$), and about 450 mJ for polycrystalline brackets ($Transcend^{TM}$ series 6000).

Study on the characteristic estimation of Permanent Magnet Synchronous Motor for On-Line Electric Vehicle considering field weakening region (약계자 영역을 고려한 온라인 전기버스용 영구자석 전동기의 특성산정 연구)

  • Son, Rak-Won;Lee, Jong-In;Kim, Wan-Gi;Kim, Keun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.798-799
    • /
    • 2011
  • 온라인 전기버스용 전동기는 차량의 운전특성을 고려하여 가속성 향상을 위한 높은 기동토크가 요구되며, 넓은 속도영역 운전을 위한 약계자 제어성능이 우수해야 한다. 특히 전동기의 최대 동작속도가 배터리 전압에 의해 결정되므로, 고속 운전영역 확보를 위해 전압제한을 고려한 전기설계가 필요하다. 본 연구에서는 정격속도 대비 최대속도의 비가 1:4로서 넓은 약계자 영역이 요구되는 온라인 전기버스용 전동기에 대해 개념설계를 진행하여 Active Part의 치수를 산출하고, 고정자 권선의 턴수 및 회전자 형상 변화에 따른 전압 및 출력특성을 비교 분석하여, 온라인 전기버스용 전동기에 요구되는 약계자 제어특성을 만족하도록 설계안을 도출하였다. 또한 전동기의 고속 동작시 주 손실인 철손에 의한 온도상승을 고려하여 영구자석의 감자안정성을 분석하였으며, 전자장 FEM 해석을 적용하여 설계결과의 타당성을 검증하였다.

  • PDF

형태안정성 레이온 복합소재의 염색특성에 관한 연구

  • Kim, Myeong-Sun;Park, Seong-Min;Gwon, Il-Jun;Seo, Mal-Yong;Kim, Hye-Jeong
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.61-61
    • /
    • 2011
  • 비스코스 레이온(Viscose Rayon)은 목재 펄프를 원료로 한 재생섬유로서 은은한 광택과 발색성, 흡습성 등의 기능 뿐만 아니라, 천연섬유에 찾을 수 없는 Numeri감(Smoothness), Drape(처짐)성, 반발탄성을 가지고 있는 지극히 친환경적이며 자연순환형 소재로 인식, 지구온난화에 따른 CoolBiz Look 패션소재인 레이온 소재에 관심이 증대되고 있다. 한편, 레이온 소재는 수분흡수 시 강도저하, 수축과 구김, 염색 불균염 등의 문제점과 섬유공정상 생활취급상에 많은 애로를 가지고 있으며, 구성고분자가 수소결합에 의해 강고하여 "신축문제", 수분흡수시 팽윤(Swelling)에 의한 형태불안, 즉 "수축문제"가 개선해야 할 고질적 문제로 남아 있다. 또한, 습식방사에 따른 분자구조적 불안정성으로 건 습열처리시 형태불안정(치수변화율이 큼)으로 제직(준비) 및 후공정상 여러 가지 Trouble 유발과 완제품 세탁시 수축발생으로 종종 Dry Creanning해야 하는 문제점들이 내재되어 있다. 따라서 본 연구에서는 레이온 소재의 형태안정화 제품을 개발하기 위하여 복합사가공 및 염색가공 기술을 개발하고자 하며, 신축 및 복합기술에 의한 Rayon DTY, T/R 신축 및 복합기술에 의한 Rayon DTY, T/R 복합가공사를 개발, 제편직 요소기술과 최적의 전처리 조건, 다양한 염료의 종류, 염색온도 조건 등에 관한 연구를 진행하였다.

  • PDF

TEMPERATURE CHANGES IN THE PULP ACCORDING TO VARIOUS ESTHETIC RESTORATIVE MATERIALS AND BASES DURING CURING PROCEDURE (광중합 시 수종의 심미적 수복재와 이장재의 사용에 따른 치수내 온도변화)

  • 장혜란;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.393-398
    • /
    • 2001
  • Polymerization of light-activated restorations results in temperature increase caused by both the exothermic reaction process and the energy absorbed during irradiation. Within composite resin, temperature increases up to 2$0^{\circ}C$ or more during polymerization. But, insulation of hard tissue of tooth lowers this temperature increase in pulp. However, many clinicians are concerned about intrapulpal temperature injury. The purpose of this study was to evaluate temperature changes in the pulp according to various restorative materials and bases during curing procedure. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece fissure bur. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn below restorative materials for evaluating of temperature changes. This thermocouple was connected to temperature-recording device(Multiplication analyzer MX, 6.000, JAPAN). Temperature changes was evaluated from initial 37.$0^{\circ}C$ after temperature changes to 37.$0^{\circ}C$. Tip of curing unit was placed in the center of prepared cavity separated 1mm from restorative materials. Curing time was 40s. The restorative materials were used with Z 100, Fuji II LC, Compoglass flow and bases were used with Vitrebond, Dycal. Resrorative materials were placed in 2mm. The depth of bases were formed in 1mm and in this upper portion, resin of 2mm depth was placed. This procedure was performed 10 times. The results were as follows. 1. All the groups showed that the temperature in pulp increased as curing time increased 2. The temperature increase of glass ionomer was significantly higher than that of Resin and Compomer during curing procedure (P<0.05). 3. The temperature increase in glass ionomer base was significantly higher than that of Calcium hydroxide base during Resin curing procedure (P<0.05).

  • PDF

AN EXPERIMENTAL STUDY ON THE TEMPERATURE CHANGE OF THE PULP CHAMBER INDECED BY THE CO2 LASER IRRADIATION (CO2레이저 조사에 따른 치수강내 온도변화에 관한 실험적 연구)

  • Lee, Jong-Man;Park, Dong-Soo;Lee, Chang-Young;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.43-53
    • /
    • 1984
  • The purpose of this study was to suggest the use of laser energy in the the field of operative dentistry without considerable pulpal damage and significant effects on the dental hard tissue, additionally to find out the methods which could control the temperature rise. The laser beam (CW $CO_2$ laser, output: 6W, beam diameter: 1.5mm) was focused on the center of the occlusal surface of extracted lower molars. A Ge lens (focal length 200mm) was used to focus the primary laser beam. In order to vary the total amount of the same irradiated energy, experimental subjects were devided into three groups: continuously irradiated group, intermittently irradiated group, and water-cooled group after continuous laser irradiation. Temperature changes in the pulp chamber after laser irradiation were measured and recorded by the digital thermometer and recorder. The following results were obtained: 1. Temperatures in the pulp chamber were raised up in the order of the continuously irradiated group, intermittently irradiated group, water-cooled group after continuous laser irradiation. 2. In the continuously irradiated group, the temperature was raised up $1.7^{\circ}C$, $3.8^{\circ}C$, $7.3^{\circ}C$, $17.2^{\circ}C$ after 2, 4, 8, 16 seconds of the irradiation of laser. In the intermittently irradiated group, the changes were $1.2^{\circ}C$, $3.4^{\circ}C$, $6.3^{\circ}C$, $11.1^{\circ}C$, respectively. In the water-cooled group after continuous laser irradiation, the changes were $0.0^{\circ}C$, $0.8^{\circ}C$, $1.6^{\circ}C$, $6.9^{\circ}C$, respectively. 3. The starting time of temperature rise in the pulp chamber had no connection with laser irradiation time.

  • PDF

A Study on the Thermal Life-Time Expectation of a NR Rubber Material using Isothermal TGA and TMA (등온 TGA 및 TMA를 이용한 NR고무소재의 내열수명 예측에 관한 연구)

  • Ahn, Won-Sool;Park, Ki-Ho
    • Elastomers and Composites
    • /
    • v.44 no.3
    • /
    • pp.269-273
    • /
    • 2009
  • A study on the life-time expectation of a CR-modified NR rubber composite through the change of thermal degradation characteristics was performed using both isothermal thermogravimetric analysis (TGA) and thermomechanical analysis (TMA). Master curves at reference temperature of $90^{\circ}C$ could be obtained with shift factor $a_T$, which was determined empirically using Time-Temperature Superposition Principle (TTSP). Activation energies could be calculated from the slope of Arrhenius plot of shift factor and showed similar values of $E_{a,TGA}$= 41.2 and $E_{a,TMA}$= 54.5 kJ/mol, respectively. It was considered from the results that chemical degradation resulting weight loss of the sample might be closely related to a physical degradation such as the dimensional change of the sample.

Studies on the Stabilization of Rayon Fabrics: 3. Effects of Long-Term Isothermal Stabilization at Low Temperatures and Chemical Pre-treatment (레이온직물의 안정화에 관한 연구: 3. 저온 장시간 등온 안정화 및 화학전처리 영향)

  • Cho, Chae Wook;Cho, Donghwan;Park, Jong Kyoo;Lee, Jae Yeol
    • Journal of Adhesion and Interface
    • /
    • v.11 no.1
    • /
    • pp.15-25
    • /
    • 2010
  • In the present study, isothermal stabilization processes for rayon fabrics were performed at two relatively low temperatures $180^{\circ}C$ and $200^{\circ}C$ for a long period of time. The results of weight loss, dimensional shrinkage, X-ray diffraction and scanning electron microscopic observations studied with the rayon fabrics before and after the isothermal stabilization indicated that the chemical and physical changes of rayon precursor fibers proceeded continuously and slowly at the stabilization temperature below $200^{\circ}C$. And the pre-treatment with four different chemical compounds done prior to stabilization process influenced differently the characteristics of rayon fabrics. As a result, it was noticed that under the given stabilization conditions, $H_3PO_4$ and $Na_3PO_4$ played a role in catalyzing the stabilization reaction of rayon fabric whereas $NH_4Cl$ and $ZnCl_2$ played a role in delaying or retarding the reaction. $H_3PO_4$ showed the lowest percent weight loss of the fabric in the second stabilization conducted at $350^{\circ}C$. It was considered that phosphoric acid, which has a function of flame retardant, contributed to retarding somewhat the subsequent reaction even in the second stabilization step.

On-Line 지필 수축 측정 기법

  • 김순배;곽동수
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.11a
    • /
    • pp.54-54
    • /
    • 2001
  • 지필의 수축 현상은 섬유의 특성, Forming 공정에서 섬유배향Drying, 온도조건, Size P Press Y- Coating 공정 에서 Rewetting, 공정 중의 Tension, Draw등에 의 해 영 향을 받게 된다. 특히 Drying 공정에서는 지필 수분이 증발하면서 섬유의 자체 수축 및 섬유결합 부의 Micro compression이 발생하게 된다. 그리고 Draw, Canvas Tension, Cylinder 온도둥과 같은 공정 조건의 변동에 따라 지필 수축률의 차이가 발생하며 제품의 M MD/CD의 강도적 특성 및 칫수안정성 컬등의 품질과 상관성을 갖는다. 일반적으로 제 품의 신축률을 측정하는 일반적인 방법은 Reel 샘플을 일정시간 침수하여 종이 내부의 응력을 제거한 후 전후의 치수 차이를 비교하는 것이다. 그러나 이 방법을 통해서는 실 질적으로 Dryer 내부의 어느 단계에서 어느 정도의 수축이 발생하는지를 판단할 수는 없다. 본 연구는 Dryer에서 Reel 까지의 종이 수축 변화를 On - Line상에서 직접 측정한 적 용 사례와 공정 조건에 따른 지필 수축의 변화를 측정한 결과에 대한 것이다. 여기서 사용된 On-Line 지필 수축기는 직진성의 레이저를 이동식 지지대에 설치하여 전/후측 의 지필과 Cy linder 양끝의 거리 차이를 측정하여 지필의 폭을 계산할 수 있도록 자체 개발하였다. 이 설비를 이용하여 Dryer 내부에서 지필 수축이 급격이 일어나는 C Cylinder 군을 찾아 스팀압력과 Bel Run의 진공도, Canvas Tension, Draw 공정조건을 조정하였고 결과적으로 제품의 신축률 개선 효과를 가져올 수 있었다. 본 연구에서 개발한 On-Line 지필 수축 측정 기법은 종이 칫수 안정성과 관련하여 향후 공정 최적화 작업의 진단 도구로서 적극적으로 활용할 수 있을 것으로 기대된다.었다. 특히 지분의 경우, 참여한 회사의 지분관련 complain이 약 80% 정도 감소하는 결과를 나타 내었다. 또한 백상지의 경우 ink jet 프린터에 많이 사용됨으로 ink jet 프린터의 인쇄 적성을 image analyzer로 측정한 결과 산화전분 보다 향상된 결과를 나타내었다. 있다 고 사료되었다.칼비터에 의한 고해나 큰 물성적으로 큰 차이를 보이지는 않고 있 었다. 단지 섬유의 차이가 고해방식의 차이보다 월등히 크다는 사실을 보이고 있다 이러한 점은 섬유장의 길이에서도 볼 수 있다. 칼비터가 섬유를 절단하기만 하고 닥방망이 고해가 섬유장의 변화를 일으키지 않는다면 틀림없이 평균 섬유장의 차이가 생길것이다.의 여수도가 7 70% 이상 개선되는 것으로 나타났다.측정하였다. 또한 카르복실기 정량과 종이의 pH 측정 및 X -ray Diffractometer를 이용하여 결정화도를 측정하였다. 본 연구의 결과, 시간의 경과에 따라서 탄소의 결합에너지는 분포가 C-H에서 COO-, 또는 C=O로 달라짐으로써 종 이가 산화되고 있다는 것을 알 수 있었다. 또한 이 결합에너지 분포의 변화가 펄프의 종류 에 따라서 다르게 이동함으로써 제조된 시트의 표면 산화반응이 서로 다르게 일어나고 있음 을 알 수 있었으며, 이는 사용한 펄프의 화학 조성분의 차이에 기인한 것이라 사료된다.>NW 단열군이 연구지역 내에서 지하수 유동성이 가장 높은 단열군으로 추정된다. 이러한 사실은 3개 시추공을 대상으로 실시한 시추공 내 물리검층과 정압주입시험에서도 확인된다.. It was resulted from increase of weight of single cocoon. "Manta"2.5ppm produced 22.2kg of cocoon. It is equal to 9% increase in index, as compared to that of control.

  • PDF

Effects of GaAs (904 nm) Low Level Laser Therapy on Dentin Hypersensitivity (과민치아에 대한 904nm GaAs 반도체레이저의 효과)

  • Won, Tae-Hee;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.4
    • /
    • pp.215-224
    • /
    • 2011
  • The aim of the study was to investigate the effects of 904 nm GaAs laser irradiation for patients with hypersensitive teeth and to find the possibility of clinical use of this Low Level Laser Therapy (LLLT) for the control of hypersensitive teeth. Eleven patients visited Dept. of Oral Medicine, Dankook University participated in this study. Each patient contributed at least two or more contralateral pairs of hypersensitive teeth with exposed dentine at cervical surfaces. Total number of teeth used from subjects participated in this study was 50: 25 experimental and control teeth respectively. All participants were treated with 904 nm GaAs diode laser every week during 4 weeks. Tactile and cold (ice stick) tests were carried out before LLLT every week during 4 weeks and 1 week later after the last LLLT by measuring visual analogue scale (VAS) of patients and by measuring a score of electrical pulp tester (EPT) simultaneously. The VAS score in tactile test decreased significantly with time, but there was not statistically difference between those of groups. The score of EPT in the experimental group was significantly higher than that of control group, although there was no change with time. In cold test, there was significant difference between two groups and cold sensitivity of the experimental group significantly decreased with time after every LLL irradiation, compared with that of control group. Based on the results, it is suggested that the 904 nm GaAs laser irradiation could be positively used as an effective, reversible method in treating cervical dentine hypersensitivity.

EFFECT OF EUGENOL AND CAPSAICIN ON THE VOLTAGE-DEPENDENT ION CHANNELS OF TRIGEMINAL AFFERENTS (삼차신경 일차구심 뉴런의 전압의존성 이온통로에 대한 capsaicin과 eugenol의 작용)

  • Kim, Ju-Youn;Park, Sang-Jin;Choi, Gi-Woon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.407-420
    • /
    • 2000
  • 삼차신경절의 뉴런이 구강악안면영역에서의 촉각, 입각, 온도각 및 통각 등 다양한 감각을 중추신경계로 전달하는 역할을 하는 것은 주지의 사실이다. 이러한 신경전달에 있어서 이온통로는 감각정보를 전달하는데 핵심적인 역할을 수행하며 특히 소디움 통로는 활동전위의 발생에 중요하다. 소디움 통로는 tetrodotoxin-sensitive(TTX-s) 및 tetrodotoxin-resistant(TTX-r) 통로로 나누어지는 데 이 중 TTX-r 통로에 발생되는 tetrodotoxin-resistant sodium current(TTX-r $I_{Na}$)는 capsaicin에 민감한 일차구심신경세포에서 유해자극에 의해 통각신호를 발생시키고 전달하는데 중요하다. 또한 칼슘 통로는 시냅스 전도에 있어서 필수적인 역할을 수행하고 있다 한편 치과영역에서 치수의 진정 목적으로 eugenol이 흔히 사용되고 있다. 그러나 eugenol의 그 작용 기전에 대해서 현재까지 이온 통로에 대한 상세한 결과가 없는 실정이며 최근의 보고에 의하면 eugenol이 capsaicin 수용기를 통하여 감각신경에 대한 억제작용을 나타낸다고 한다. 따라서 본 실험은 eugenol과 capsaicin이 흰쥐의 삼차신경절의 TTX-r $I_{Na}$와 칼슘통로에 어떠한 영향을 미치는지를 알아보고 eugenol이 capsaicin 수용기를 통하여 작용하는지를 검증하고자 시행되었다. 삼차신경절 뉴런은 100~150g의 흰쥐의 삼차신경절로부터 외과적으로 절제하여 통법의 화학적 및 기계적 처리를 통해 단일세포로 분리하였고 이를 whole-cell patch clamp 방법을 이용하여 시행한 바 다음과 같은 결론을 얻었다. 1. 1mM의 dugenol은 흰쥐 삼차신경절 뉴런의 TTX-r $I_{Na}$와 HVA $I_{Ca}$를 억제하였다. 2. $1{\mu}m$의 capsaicin은 흰쥐 삼차신경절 뉴런의 TTX-r $I_{Na}$와 HVA $I_{Ca}$를 억제하였다. 3. Capsazepine은 capsaicin의 HVA $I_{Ca}$에 대한 억제작용을 차단하였다. 4. Capsazepine은 capsaicin의 HVA $I_{Ca}$에 대한 억제작용을 차단하지 못하였다. 결론적으로 eugenol과 capsaicin은 tetrodotoxin-resistant sodium current(TTX-r $I_{Na}$)와 high voltage-activated calcium current(HVA $I_{Ca}$)를 모두 억제하는 것으로 나타났으며, 이러한 작용이 통각의 발생과 시냅스 전달과정을 차단하여 치수 진정 목적으로 많이 사용하는 eugenol의 작용기전으로 판단된다. 한편 capsaicin의 길항제인 capsazepine을 전처치하였을 때에도 eugenol의 HVA $I_{Ca}$에 대한 억제효과는 변화가 없었다. 이와같은 결과로 보아 HVA $I_{Ca}$에 관한 한 eugenol은 capsaicin 수용기를 통하여 나타나지 않는 것으로 사료된다.

  • PDF