• Title/Summary/Keyword: 치수 온도변화

Search Result 74, Processing Time 0.021 seconds

TEMPERATURE CHANGE IN THE PULP ACCORDING TO POLISHING CONDITION OF VARIOUS RESTORATIVE MATERIALS (여러가지 수복물의 polishing조건에 따른 치수 온도변화)

  • Baik, Byeong-Ju;Park, Jong-Ha;Yang, Jeong-Suk;Lee, Seung-Young;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.365-376
    • /
    • 1999
  • The importance of finishing and polishing the restoration has been described by several authors. The final step provides for improved metallurgical properties, better marginal adaptation, reduced plaque accumulation. Unfortunately, finishing of the restorations can produce damage from temperature rises at the pulpal wall. The aim of this study was to determine the changes in temperature can be occurred during the use of finishing and polishing instruments under a variety of conditions. ; with or without a water coolant, intermittent or continuous operation, high or low rotation speed, remaining dentin thickness and various restorative materials. Class V preparations were cut on extracted molars and restored with composite resin(Z 100), resin-modified glass ionomer cements(Dyract, Fuji II LC), and amalgam. Finishing was done with aluminum oxide coated disc($Sof-lex^{(R)}$ polishing disc, 3M, USA). The following results were obtained. 1. The rise of temperature during polishing of amalgam restorations was the highest among the all experimental groups except polishing with water coolant(P<0.05). However, there were no statistical differences in temperature rises between Z 100, Dyract and Fuji II LC(P>0.05). 2. The intrapulpal temperature was greatly influenced by the applied time, and intermittent polishing was showed significantly lower temperature rises than continuous polishing(P<0.01). 3. The intrapulpal temperature was increased according to the application of polishing regard less of using water coolant. However, polishing with water coolant showed significantly lower temperature in the pulp than not used water coolant(P<0.01).

  • PDF

Effects of mold temperature on the part dimension and surface quality of the injection molded cavity filter (금형온도가 Cavity Filter 성형품의 치수 및 외관품질에 미치는 영향에 관한 연구)

  • 김동학;김태완
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.359-361
    • /
    • 2003
  • 본 연구에서는 무선부품의 일종인 cavity filter 금형을 제작하였고, 도금용 ARS 수지와 PC/ARS Alloy 수지를 사용하여 일반사출성형과 금형온도가 높은 MmSH방식, 두 타입으로 성형품을 제작하였다. 성형품의 수축률 변화는 MmSH 방식일 때 ABS 수지로 제작한 성형품의 단위캐비티 격막부분에서 수축률이 감소되었다. 중량변화는 ABS와 PC/ABS Alloy로 제작된 성형품 모두 MmSH 방식일 때 증가하였고. 성형품의 표면 거칠기도 모두 MmSH 방식일 때 거칠기가 감소되었다.

  • PDF

EVALUATION OF THERMAL DIFFUSION IN LOWER End PRIMARY MOLAR WITH THERMOGRAPHY AND FINITE ELEMENT ANALYSIS (Thermography와 유한요소분석법을 이용한 하악 제2유구치의 열확산도 평가)

  • Park, Hee-Seung;Kim, Yong-Kee;Kwon, Soon-Won;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.519-528
    • /
    • 2002
  • It is not a rare occasion that certain dental procedures involving tooth reduction being peformed under inadequate water cooling due to a variety of reasons. This situation could possibly inflict the critical insult to the pulpal tissue of indicated tooth. The purpose of this experiment was to study the pattern of diffusion of external heat produced during routine dental procedures into the pulpal tissue. 30 stone blocks containing three lower second primary molars were used for certain restorative procedures and the temperature of the indicated tooth surface was measured by thermography(Inframetrics 600) and further used as a baseline data for the finite element analysis model fabrication designed in order to evaluate the pattern of thermal diffusion. The ranges of highest surface temperature measured from several dental procedures under water cooling and non-water cooling were $30.8^{\circ}C{\sim}43.6^{\circ}C$ and $51.2^{\circ}C{\sim}103.4^{\circ}C$ respectively. Among procedures studied, crown preparation showed the highest value and amalgam removal showed the lowest. Comparisons between data measured under water cooling and non-water cooling conditions have shown the statistically significant difference(p<0.05). All the non-cooling conditions have shown the relatively larger increment of temperature change at the pulp horn area than the cooling conditions. The results of this study strongly indicate that the water coolant is the essential element in restorative procedures for the maintenance of healthy pulp. Further related studies involving more procedures and conditions are recommended.

  • PDF

A Study of Characteristics Change of Low-Shrinkage Normal Strength Concrete According to Mixing Factors and curing Temperature (배합요인과 양생온도에 따른 일반강도 초저수축 콘크리트의 특성 변화 연구)

  • Jeong, Jun-Young;Min, Kyung-Hwan;Lee, Dong-Gyu;Choi, Hong-sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.342-347
    • /
    • 2016
  • This study examined the effects of the coarse aggregate maximum size and grading of fine aggregates to acquire the characteristics of very low shrinkage on normal strength concrete mixed in the field. In addition, the shrinkage characteristics of concrete under construction were evaluated in accordance with the curing temperature. The compressive strength and drying shrinkage tests were performed for nine mixing factors composed of the coarse aggregate size (13, 20, and 25 mm), types of fine aggregate (see sand, crushed sand, and blended sand), and curing temperatures (5, 20, and $35^{\circ}C$). To acquire low shrinkage properties under $350{\mu}{\varepsilon}$ strain on normal strength concrete, a 25 mm maximum of coarse aggregate was available, and the grading of fine aggregate affected the shrinkage of concrete. In addition, very low shrinkage properties were acquired in the curing temperature range except cold and hot weather concrete.

A Study of Temperature Changes in the Dental Tissues Irradiated by $10.6{\mu}m$ Laser Beam ($CO_2$ 레이저 광의 조사조건에 따른 치아의 치수강내 온도상승에 관한 연구)

  • Ko, D. S.;Bak, Y. H.;Shin, S. H.;Eom, H. S.;Kim, U.;Lee, C. Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.210-216
    • /
    • 1990
  • This study was performed to obtain fundamental data on temperature increases in the dental tissues irradiated by IO.opm laser radiation. For this purpose a experimental facility was established. which was composed of a CO2 laser. a shutter unit and a temperature sensing device. The temperature changes in the pulp chamber of extracted molars. during and after the laser irradiation. were measured as function of laser power. the time of irradration and the thickness of the sample. An empirical formula for the maximum temperature increases, $\DeltaT_m$ was derived from the measured data as follows; $\DeltaT_m=\alphaP\Delta\tauexp(-\betad)$$ where P. $\Delta\tau$ and d are the laser power(W). irradiation time{sec) and the thickness(mm) between pulp chamber and occlusal surface. respectively. Also a theoretical calculation model based on simplified assumptions were established and the results from the calculation were compared with the measured temperature data. A fairly good agreement was obtained.obtained.

  • PDF

A study on the mold design improvement of the clamp chuck by using CAE simulation (CAE 응용설계 기법을 이용한 클젬프 척(Clamp chuck)의 금형설계 개선에 관한 연구)

  • 신명균;허용정;강성남
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.74-77
    • /
    • 2000
  • 사출성형에 관한 연구는 오랜 역사를 가지고 있으며 공정 시뮬레이션을 위한 상용화된 CAE 프로그램을 포함하여 많은 연구가 진행되는 분야중의 하나이다. 그러나 다양한 고분자 재료의 성질, 금형의 복잡한 형상 및 성형조컨 둥의 변화로 인해 금형설계 및 제작 그리고 사출성형시 상당한 어려움을 겪게 된다. 사출성형 공정에서는 금형온도, 플라스틱 재료, 냉각수, 보압과 사출압 등의 여러 가지 공정변수가 있어 현장전문가의 경험에 의해 사출금형의 제작이 이루어지는 경우가 보통이다 이와 같은 경험에 의한 금형 제작은 상당한 납기지연과 노동집약적인 방식으로 흘러가게 된다. 금형 제작시 가장 고려해야 될 사항 중의 하나는 사출성형품의 수축이다. 사출성형에서 광음수지는 냉각, 고화하면서 수축하는데 성형품 치수를 유지하기 위해서는 수축하는만큼 금형의 치수를 보정하여야 한다. 이 수축률은 사용수지의 종류와 성형품 크기, 살두께 등에 따라 다르다. 또 동일한 수지일 경우에도 성형조건에 따라 변화하고 특히 배향성을 가진 수지는 유동방향에 따라서도 변화가 있다. 즉, 금형의 온도가 높으면 수축률은 증가하고 사출압력이 높으면 감소한다. 또한 살두께가 두껍고 길이가 길 때 수축률은 증가한다 방향성이 있는 수지는 유동방향에 대하여 지각방향에서 가장 적다. 특히 방향성이 현저한 HDP에서는 유동방향에 따라 수축차가 크므로 성형할 때 변형을 일으키는 경우가 많다. 일반적으로 PE, PP. PA와 같은 결정성 수지는 PS, SAM, ABS 등의 비결정성 수지보다 수축률이 크다. 본 연구에서는 한조산업사에서 제작한 '클랠프 척' 금형 제작과정에서 성형품의 수축으로 인한 금형의 치수보정에 있어서의 문제점을 유동해석 전용 CAE 프로그램인 C-mold를 사용하여 해석하고 평가하였다. 그리하여 현장 전문가가 경험적으로 여러 번의 시행착오를 거쳐 완성된 금형을 제작하던 기존의 방법보다 체계적이고 합리적이며 또한 신속하게 문제를 해결함으로써 궁극적으로 금형설계 및 제작기간을 단축하고자 한다.

Temperature change in pulp chamber of teeth by $CO_2$ laser irradiation ($CO_2$ 레이저 광의 조사 조건에 따른 치아의 치수강내 온도변화)

  • 엄효순
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.45-48
    • /
    • 1990
  • CO2 laser beam was focused by a ZnSe lens onto the center of the occlusal surface f extracted lower molars. K-type thermocouple was contacted with the pulp chamber and the changes of temperature in the during and after the laser irradiation were measured as function of the power of laser beam, the time of laser irradiation and thickness of the sample. An empirical formula for temperature effect was derived from the measured data.

  • PDF

CAE Simulation Study an Filling Imbalance in Multi-Cavity Injection Molding (다수 캐비티 사출성형에서 충전 불균형 현상에 관한 시뮬레이션)

  • Jeon, Kang-Il;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.678-681
    • /
    • 2009
  • 사출성형은 열가소성수지의 가공법으로써 정밀도나 고품질의 제품을 효과적으로 생산하는데 널리 이용되며 플라스틱은 현재 광범위하게 사용되고 있는 공업재료 중의 하나이다. 과거에는 플라스틱을 일회용품 및 외장재로 사용하였다. 그러나 산업기술이 발전하며 플라스틱은 금속을 대체 할 수 있는 재료로서 사용할 수 있다는 인식의 변화로 점차 기계요소용 재료로 사용되고 있으며 기계요소용 재료로 사용됨에 따라 플라스틱 제품이 정밀한 부품으로 사용되기 위해서는 금형의 가공뿐만 아니라 사출성형 시 용융수지가 금형의 각 캐비티에 균형적으로 충전되는것이 요구된다. 이러한 요구조건을 만족하기 위해서는 각 캐비티의 가공치수는 매우 높은 정밀도를 유지해야 하며, 각 캐비티에서의 충전과 냉각도 동일한 상태를 유지해야 한다. 충전 불균형은 성형품의 품질에 큰 저해 요인으로서 플라스틱 제품의 치수성, 밀도, 외관품질, 강도 등에 불균일한 결과를 가져오는 요인으로 지적되고 있다. 실제로 충전 불균형은 충전 단계에서 런너 내에서 발생하는 불균일한 전단분포에 기인하여 발생되므로 점도변화에 영향을 주는 수지의 물성, 런너의 배열과 같은 외부 요인과 사출압력, 사출속도, 수지온도, 금형온도와 같은 성형공정 조건에 의한 요인에 의한 충전 불균형의 양상이 달라지게 된다. 본 연구는 다수 캐비티 금형에서 충전 불균형 현상에 대한 원인을 검토하고 실제로 사출성형을 실시하기 전 사출성형해석 소프트웨어를 이용하여 시뮬레이션을 하여 다수 캐비티에 대한 충전 패턴을 미리 예측하여 보았다.

  • PDF

Effect of Chain Orientation on the Optical Properties and Dimensional Stability of Polyethersulfone Film (주사슬 배향이 폴리에테르설폰 필름의 광학 특성 및 치수안정성에 미치는 영향)

  • Kim, Jae-Hyun;Kim, In-Sun;Kim, Yang-Kook;Kang, Ho-Jong
    • Polymer(Korea)
    • /
    • v.34 no.3
    • /
    • pp.220-225
    • /
    • 2010
  • The optical properties and dimensional stability of polyethersulfone(PES) retardation film have been studied as function of chain orientation and the temperature applied to PES retardation film. It was confirmed that the appropriate retardation values of $R_e$ and $R_{th}$ for the retardation film application were able to obtain by the chain orientation and these values could be controlled by the chain relaxation through the thermal annealing process. It was found that unstable $R_e$ and $R_{th}$ values were shown by the repeated cooling and heating applied to the retardation films but this could be stabilized by means of the annealing process after stretching of PES film. The dimensional shrinkage due to the chain orientation was found as temperature increase and the intrinsic thermal expansion of PES appeared after shrinking. The shrinkage of PES films affected by the chain orientation and thermal annealing dramatically but the effect on the coefficient of thermal expansion was found to be negligible.

PULSE OXIMETER AS A DIAGNOSTIC TEST OF PULP VITALITY (Pulse Oximeter를 이용한 치수생활력측정)

  • Koo, Bon-Kyung;Lee, Jae-Ho;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2000
  • Traditionally, EPT and thermal tests were used as diagnostic methods for pulp vitality test. The thermal and electrical stimulation tests are the methods to determine the vitality of a tooth based on its neuronal response. These have certain limitations, one of them is the difficulty of approaching the correct result in case of treatment of children. The reason is management problem caused by the unpleasant stimulation. Also, the response from patients are not objective, and false positive or false negative could be happened. Recently, laser doppler flowmetry and pulse oximeter which evaluate vascular integrity are introduced in an effort of overcoming to limitation of traditional methods. The principle of pulse oximeter is to and out level of oxygen saturation by ratio of the two pulses between emitted light and detected light penetrating them to the termination of body, such as ears or fingers. From this point of view, it can be applied to a tooth to determine its vitality. The objective of this study lies mainly on varifying pulse oximeter as a method of determining tooth vitality and providing basic data of its clinical implementation. The result of the research showed that level of oxygen saturation in vital teeth was average of 96.3% and 0.0% in pulpless teeth. As a comprehensive result, pulse oximeter could be an useful diagnostic equipment in determining of tooth vitality.

  • PDF