A Study on The Regional Variation of Hypertension Medication Rate (고혈압 약물치료율의 지역 간 변이에 관한 연구)

  • Seok, Hyang-Sook;Kang, Sung-Hong
    • Journal of Digital Convergence
    • /
    • v.11 no.9
    • /
    • pp.255-265
    • /
    • 2013
  • The purpose of this study was to identify the variation factors of hypertension medication rate between regions and to use them as a basic data for establishment of hypertension management business plan which is customized by region. The data were collected from community health survey, National Statistics Office and National Health Insurance Corporation, and were analyzed using the geographically weighted regression. As the result of analysis, the factors that influenced the hypertension medication rate between regions were subjective recognition rate of health level, the rate of medical aid client and the number of health facility per one hundred thousand of population. According to the geographically weighted regression, the total of 230 regional regression models composed of major variables which affected the hypertension medication rate were calculated. However, this study has several limitations that the explanatory power of model is not high and others. Therefore, a follow-up study which is based on the actual data of compliance with hypertension medication will be necessary.

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.

Reliable Radiologic Parameters to Predict Surgical Management for Clubfoot Treated with the Ponseti Method (Ponseti 방법으로 치료를 시작한 선천성 만곡족 환자에서 수술적 치료 여부를 예측할 수 있는 방사선적 지표)

  • Song, Kwang Soon;Yon, Chang Jin;Lee, Si Wook;Lee, Yong Ho;Um, Sang Hyun;Kwon, Hyuk Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.59-66
    • /
    • 2019
  • Purpose: Several radiologic reference lines have been used to evaluate individuals with a clubfoot but there is no consensus as to which is most reliable. The aim of this study was to identify which radiologic parameters have relevance to the predictability of additional surgery after Ponseti casting on clubfoot and the effect of clubfoot treatments that contain Ponseti casting and additional surgery. Materials and Methods: A total of 102 clubfeet (65 patients, 37 bilateral) were reviewed from 2005 to 2013. The patients were divided into two groups (Group A, those for whom the result of the Ponseti method was successful and did not require additional surgery; and Group B, those for whom the result of the Ponseti method was unsuccessful and required additional surgery), and the following parameters were measured on the plain radiographs: i) talo-calcaneal angle on the anteroposterior and lateral view, ii) talo-1st metatarsal angle on the anteroposterior view, and iii) Tibio-calcaneal angle on the lateral view with the ankle full-dorsiflexion state. Each radiograph was reviewed on two separate occasions by one orthopedic doctor to characterize the intra-observer reliability, and the averages were analyzed. Next, 20 cases were chosen using a random number table, and two orthopedic doctors measured the angle separately to characterize the interobserver reliability. Results: Groups A and B included 73 clubfeet (71.6%) and 29 clubfeet (28.4%), respectively. The initial talo-calcaneal angle and tibiocalcaneal angle in the lateral view were significantly different among the groups. In addition, inter- and intra-observer biases were not detected. The talo-1st metatarsal angle on the anteroposterior view and tibio-calcaneal angle on the lateral view were significantly different after treatment in both groups. Conclusion: Congenital clubfeet treated with the Ponseti method showed successful results in more than 70% of patients. The initial talocalcaneal angle and tibio-calcaneal angle on the lateral view were the radiologic parameters that could predict the need for additional surgical treatments. The talo-1st metatarsal angle on the anteroposterior view and tibio-calcaneal angle on the lateral view could effectively evaluate the changes in clubfoot after treatment.

생명 연장의 신기원 간이식

  • 한국간협회
    • 간의등불
    • /
    • s.18
    • /
    • pp.16-23
    • /
    • 2001
  • 치료 불가능한 말기 간질환 환자에게 새로운 간을 심어주는 수술을 하여 생명을 구하고 더 나은 삶을 누릴 수 있게 하는 간 이식에 대하여 알아본다. 아울러 한국 장기 이식의 현주소와 그 미래, 산 자와 죽은 자에 대한 보고서이기도 한 간 이식은 의학의 차원을 넘어 생명의 존재 가치에 대한 진지한 질문을 던져줄 것이다.

  • PDF

Oral Health Status and Dental Treatment Need of Liver Transplant Candidates (간 이식 예정 환자의 구강건강상태 및 치과치료 요구도에 관한 연구)

  • Park, Tae-Jun;Kho, Hong-Seop
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • Liver transplantation is definitive treatment for the patients suffering from hepatitis, severe liver cirrhosis and liver cancer. In these patients, systemic infections under immunosuppression may occur easily. Therefore, primary object of dental treatments before liver transplantation is absolute removal of oral infection source. In addition, comprehensive dental management plan is essential for success of liver transplantation. The present study has been performed to investigate decayed, missing and filled permanent teeth index(DMFT index), degree of oral hygiene, past medical history, need of dental treatment, completion of dental treatment need and time interval between dental visit and operation date of liver transplantation in liver transplant candidates. Obtained results were as follows; 1. Decayed teeth of the patients were 2.68, missing teeth were 4.02 and filled teeth were 3.42. DMFT index was 10.12. 2. Twenty percents of patients showed moderate to severe food impactions, 42.2% of patients had moderate to heavy calculus and 37.8% of patients displayed gingival inflammation with swelling. 3. Patients needed periodontal treatments more than any other dental treatments. Periodontal treatments were needed for 88.9% of patients, operative & endodontic treatments were 46.7% of patients and 33.3% of patients needed for oral & maxillofacial surgical treatments. 4. Among 90 patients, time interval between scheduled operation date of liver transplantation and dental visit was within 2 weeks for 32.2% of patients, within 1 week for 20.0% of patients. In conclusion, most liver transplant candidates needed dental treatments for removal of potential infection sources. However because of insufficient interval between dental visit and operation date, they had taken liver transplantation procedures without comprehensive dental management. Development of preventive and comprehensive dental management program is mandatory for these patients. Cooperative interdisciplinary management will play a positive role for successful liver transplantation.

Hepatitis B Virus Reactivation after Partial Hepatic Irradiation Alone: A Case Report (부분 간조사만을 시행받은 환자에서의 B형 간염바이러스의 재활성화: 증례보고)

  • Kim, Bo-Kyong
    • Radiation Oncology Journal
    • /
    • v.28 no.2
    • /
    • pp.106-110
    • /
    • 2010
  • Reactivation of the hepatitis B virus (HBV) is a well-recognized complication in patients with chronic HBV infection who receive cytotoxic or other immunosuppressive therapy. In cases of patients treated by radiotherapy however, only a few of such reports exist and most of these include the patients previously treated by chemotherapy or transarterial chemoembolization. The results of this study point to a case of a patient with reactivation of HBV after radiotherapy alone. This study shows the possibility of HBV reactivation by partial hepatic irradiation alone hence, special attention should be paid to patients with HBV disease.

A Design of Active Robot System for Speech Therapy (능동적인 언어치료 로봇시스템 설계)

  • Yun, Jae-Min;Jee, Min-Sung;Shin, Dong-chun;Ko, Yeon-Jeong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.687-688
    • /
    • 2022
  • 기존 언어치료는 언어발달장애 아동과 언어치료사간의 대면 방식으로 이루어지며, 이때 각종 언어치료도구가 사용된다. 본 시스템은 언어발달장애 아동과 로봇 간의 언어치료를 위해서, 센서를 통한 아동 이동 접근 확인, 아동 얼굴 검출, 아동 얼굴 인식, 아동 얼굴 감정 인식, 아동 얼굴 추적, 감정 돌봄 대화 출력, 언어치료 콘텐츠 표시, 음성대화를 통한 언어치료 수행이 어떻게 적용되는지 개념을 설명하고자 한다.

Bronchial Artery Embolization(BAE) for Hemoptysis of Small Amount : A Comparative Study with Conservative Management (소량객혈 환자에서 동맥색전술과 보존적치료의 비교연구)

  • Ryu, Jeong-Seon;Song, Kwang-Seon;Yong, Suk-Joong;Lee, Hong-Lyeol;Chang, Joon;Shin, Kye-Chul;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.629-638
    • /
    • 1997
  • Background : Surgical intervention is known as the principle management for hemoptysis of significant amount. But surgical procedure is applicable to only small number of patients because of increased mortality in emergency surgery and various functional and structural problems after lung resection. Bronchial artery embolization(BAE) has been used as an alternative interventional technique for immediate control of patients with increased risk for surgery due to recurrent or massive hemoptysis. BAE also has limitations such as recurrent bleeding after procedure and its role for the application to small amount of hemoptysis is still not established. Method : To evaluate immediate and long term effectiveness of BAE, we analysed 65 patients with hemoptysis according to therapeutic modalities they received ; BAE versus conservative management. Results : The success rate for immediate control of hemoptysis was significantly higher in BAE group with 43 cases(100%) among 43 cases compared with 17 cases(77%) among 22 cases in conservative group (p < 0.001). The disease control duration was $19.5{\pm}8.06$ months in BAE group and $18.8{\pm}6.06$ months in conservative group(p > 0.05). The therapeutic response in BAE group was 82%(36/43 cases) and 95%(21/22 cases) in conservative group (p > 0.05). According to the amount of hemoptysis, the therapeutic response were seen in 91%(29/32 cases) in less than 100ml and 85%(28/33 cases) in 100~400ml (p > 0.05). According to the manifestation of hemoptysis, the therapeutic response in groups of recurrent and nonrecurent were 87%(20/23 cases) and 88%(37/42 cases)(p > 0.05). Conclusion : The difference of therapeutic response between BAE and conservative group in patients with small amounts of hemoptysis was not found except for immediate control of hemoptysis.

  • PDF

Influence of Couch and Collimator on Dose Distribution of RapidArc Treatment Planning for Prostate Cancer in Radiation Therapy (치료테이블과 콜리메이터가 전립선암 래피드아크 치료계획의 선량분포에 미치는 영향)

  • Kim, Hyung-Dong;Kim, Byung-Young;Kim, Sung-Jin;Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • We investigated the influence of photon energy, couch and collimator angle differences between arcs on dose distribution of RapidArc treatment planning for prostate cancer. RapidArc plans were created for 6 MV and 10 MV photons using 2 arcs coplanar and noncoplanar fields. The collimator angle differences between two arcs were $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$ and $90^{\circ}$. The plans were optimized using same dose constrains for target and OAR (organ at risk). To evaluate the dose distribution, plans were analyzed using CI (conformity index), HI (homogeneity index), QOC (quality of coverage), etc. Photon energy, couch and collimator angle differences between arcs had a little influence on the target and OAR. The difference of dosimetric indices was less than 3.6% in the target and OAR. However, there was significant increase in the region exposed to low dose. The increase of V15% in the femur was 6.4% (left) and 5.5% (right) for the 6 MV treatment plan and 23.4% (left), 24.1% (right) for the noncoplanar plan. The increase of V10% in the Far Region distant from target was 54.2 cc for the 6 MV photon energy, 343.4 cc for the noncoplanar and 457.8 cc for the no collimator rotation between arcs.