Journal of the korean academy of Pediatric Dentistry
/
v.49
no.4
/
pp.442-452
/
2022
The purpose of this study was to compare the mesio-distal and vertical position of impacted maxillary canines on panoramic radiographs with the labio-palatal position of impacted canines and root resorption of adjacent teeth on CBCT (Cone-Beam Computed Tomography). A total of 54 patients with 69 impacted maxillary canines were included in this study. On panoramic radiographs, the mesio-distal (Sector I - V), and vertical position, and angulation of impacted maxillary canines were evaluated. Labio-palatal position and root resorption of adjacent teeth were evaluated on CBCT. Labial impaction of canines was most frequent in panoramic sector I. Impaction within the arch was most frequent in sector I and II. Palatal impaction was most frequent in sector III, IV, and V. Mesially positioned canines on panoramic radiographs tended to be palatally impacted. Most of the root resorption of adjacent teeth occurred in sector III, IV, and V (p < 0.05). Canines with low angulation on panoramic radiographs tended to be palatally impacted and resorb the roots of adjacent teeth. The vertical position of impacted canines on panoramic radiographs was not statistically significant with respect to labio-palatal position and root resorption of adjacent teeth on CBCT. Analysis of the mesio-distal position and angulation of impacted maxillary canines on panoramic radiographs can be used to predict the labio-palatal position of impacted canines and root resorption of adjacent teeth.
The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.
Objective: The aim of this study was to evaluate the potency of panoramic radiography for the detection of maxillary impacted canines. Methods: Twenty-five patients were selected, comprised of 7 males (mean age: 10.9 years, range: 8.5 - 14.5 years) and 18 females (mean age: 10.9 years, range: 8.2 - 15.7 years). In total, thirty-five maxillary impacted canines were estimated. The position of the canine and root resorption of adjacent teeth were evaluated on panoramic radiography and 3D CT. Results: Except for angulation to the occlusal plane, the other parameters, such as tooth length, crown width, vertical distance and lateral shift showed larger values on panoramic radiography compared to 3D CT. In palatally impacted cases, the angulation of canine was smaller, and the vertical distance to the occlusal place was larger on panoramic radiography than 3D CT. For labially impacted canines, tooth length, crown width, and angulation to the occlusal plane were similar for the two methods. The sensitivity for detecting root resorption on panoramic radiography was calculated as being 33.3% of 3D CT. Conclusions: The position of labially impacted canines can be effectively estimated using panoramic radiography, but palatally impacted canines need further investigation such as 3D CT for proper diagnosis.
This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.
최근 임플란트를 원하고, 필요로 하는 환자가 증가하면서 술전의 정확한 진단이 보다 중요해졌고 다양한 진단방법이 소개되고 이용되어져 왔다. 그 중 보편적으로 가장 널리 사용되어지는 방법이 방사선 촬영법이고 그 중에서도 파노라마방사선사진이다. 하지만 파노라마방사선사진의 용이함과 간편성에도 불구하고 그 방법 자체가 가지고 있는 한계점 때문에 CT/MPR(Computer Tomography/Multiplanar Reformatting)이 일부 환자에서는 반드시 필요하다는 주장이 대다수이다. 본 연구의 목적은 하악 구치부에 임플란트 시술을 받은 환자를 대상으로 파노라마방사선사진의 확대율을 알아보고 파노라마방사선사진과 CT/MPR에서 치조정-하악관간 거리가 실제 어느 정도 차이를 보이는지, 그리고 CT/MPR에 대한 파노라마방사선사진의 확대율에 환자의 하악골의 경사도와 하악관의 해부학적 위치가 어떤 영향을 미치는지를 알아보는 것이다. 본 연구는 서울대학 치과병원 치주과를 내원하여 하악구치부에 Dental Implant 시술을 받은 15명의 환자, 32개 부위를 대상으로, 임플란트 시술을 위한 술전 파노라마방사선사진과 CT/MPR, 술후의 파노라마방사선사진, CT/MPR상을 자료로, 임플란트가 식립될 위치에서 치조정에서 하악관의 길이, 하악골의 협설폭경, 하악골의 설측면에서 하악관의 수평길이, 임플란트 매식체의 설측에서 하악관까지의 수평거리를 계측하였고 이 해부학적 계측치들이 CT/MPR에 대한 파노라마방사선사진의 확대율과 어떤 상관관계에 있는지 Pearson's correlation coefficient test를 이용해 살펴보았다. 1. CT/MPR에 대한 파노라마방사선사진의 확대율은 CT/MPR상에서 하악골 단면의 협설폭경(Pearson test에서의 상관관계 분석시, 상관계수 r=-0.604), 임플란트 매식체의 설측에서 하악관까지의 수평거리(r=-0.515), 하악골의 설측면에서 하악관까지의 수평거리(r=-0.640)와 뚜렷한 음적 선형관계가 있었다. 2. CT/MPR에 대한 파노라마방사선사진의 확대율은 CT/MPR상에서 하악골의 장축의 각도와는 뚜렷한 양적 선형관계(Pearson test에서의 상관관계 분석시, 상관계수 r=-0.446)가 있었다. 3. 여러 요소중 CT/MPR에 대한 파노라마방사선사진의 확대율과 가장 유의성있는 연관성을 보이는 것은 CT/MPR상에서 하악골의 설측면에서 하악관까지의 수평거리였다(r=-0.640) 4. CT/MPR에 대한 파노라마방사선사진의 확대율은 일반적으로 생각되어지는 파노라마방사선사진의 확대율 125%보다 큰, 약 135%로 나왔다. 이상의 결과로 볼 때, 하악골의 설측면에서 하악관까지의 수평거리가 CT/MPR에 대한 파노라마방사선사진의 확대율에 가장 영향을 미치는 요소로 추정되며 확대율은 125%보다 높은 것으로 나타났다.
This study is designed to assess Relationship between clinical diagnosis of Temporomandibular Joint Disorder and diagnostic finding of Cone Beam Computed Tomography(CBCT) The author performed clinical examination for TMD Patients who visited Orofacial pain clinic, Jin-ju ooo Dental office. CBCT(Cone beam computed tomography) was taken for 190 joints in 95 subjects. A Oral medicine and Oral radiologist evaluated CBCT each other. then we compared with that result, Condyle bony changes were classified by no bone change, flattening, erosion and osteophyte. The obtained results were as follow: 1. The Kappa index of the diagnosis between oral medicine and oral radiogist were high, the index of diagnosis by degenerative joint disease were more higher. 2. The Kappa index of panoramic view and CBCT was low, more condylar bone chages were observed by CBCT diagnosis 3. Condylar bone changes of the 54.2% of non-DJD group clinicaly was observed by CBCT diagnosis and no bone changes of the 15.3% of DJD group.was observed by CBCT 4. TMJ pain was associated with erosion of condyle bone change of TMJ. Crepitation and longest duration of TMD were associated with osteophytic bone change.
Objective: The purpose of this study was to evaluate the effect of head position changes on the root parallelism between adjacent teeth on panoramic radiographs. Methods: A model with normal occlusion was constructed in the SolidWorks program, then RP (rapid protyping) model was fabricated. The model was repeatedly imaged and repositioned five times at each of the following nine positions: ideal head position, $5^{\circ}$ up, $10^{\circ}$ up, $5^{\circ}$ down, $10^{\circ}$ down, $5^{\circ}$, right, $10^{\circ}$, up, and $5^{\circ}$ right rotation, $10^{\circ}$ right rotation. Panoramic radiographs were taken by Planmeca ProMax and the angle between the long axes of adjacent teeth was directly measured in the monitor. Results: Axes of adjacent teeth tended to converge toward the occlusal plane when the head tilted up and converged in the opposite direction to the occlusal plane when the head tilted down. Anterior teeth showed the most notable differences. When one side of the head tilted up $5^{\circ}$ and $10^{\circ}$ along the anteroposterior axis (Y axis), tooth axes of the same side tended to converge toward the occlusal plane and tooth axes of the opposite side tended to converge in the opposite direction to the occlusal plane. When the head rotated to one side along the vertical axis (Z axis), the canine and lateral incisor of the same side converged in the opposite direction to the occlusal plane and the canine and lateral incisor of the other side converged toward the occlusal plane. Conclusions: When assessing the root parallelism on panoramic radiographs, the occlusal plane cant (anteroposterior or lateral) or asymmetry of the dental arch should be considered because these can cause distortion of tooth axes on panoramic radiographs.
To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.
Journal of Korean Academy of Oral and Maxillofacial Radiology
/
v.29
no.1
/
pp.255-260
/
1999
Purpose: The objective of this study was to evaluate the possibility of substitution of the zonography for the full-mouth periapical radiography in aspect of radiation protection. Materials and Methods: Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses at brain, skin above the TMJ. parotid gland. bone marrow in the mandibular body. and thyroid gland during the full-mouth periapical radiography. panoramic radiography. and zonography were measured. Resul ts: From the zonography. the absorbed doses to the brain. the skin over the TMJ. and the parotid gland were relatively high. but the absorbed doses to the bone marrow in the mandibular body and. especially. the thyroid gland were very low. Conclusion: The zonography can be an alternative to the full-mouth periapical radiography in aspect of radiation protection.
In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.