• 제목/요약/키워드: 치과 보철물

Search Result 814, Processing Time 0.022 seconds

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

Applying the New Technology for Making Pontic Ridge Lap in Posterior Bridge Restoration (대체 신기법을 적용한 구치부 교의치 pontic ridge lap 제작방법)

  • Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.308-316
    • /
    • 2013
  • The purpose of this study is to investigate the production method of posterior bridges pontic ridge lap type which prevents the infection in bridge pontic base and is able to cleanse itself, in the process of producing final prothesis that maintains healthy mucous membrane of oral cavity and interproximal papilla, minimizing diastema, is aesthetic and has no effect on pronunciation. New technology is applied to make optimal pontic base which prevent inflammation and clean itself and its products were clinically evaluated in 10 places of dental clinics in busan and gyeongnam. The making of posterior 3 unit bridge pontic base, it was presented as the new technology of forming ridge lab type and to carry out clinical validation, existing conventional method and the new technology were compared. Pontic base made with the existing conventional method cause infection and other periodontal disease by 96% but the pontic base made with the new technology cause infection and other periodontal disease by 3%. Remains of food cause infection and other periodontal disease 100% by the existing conventional method and 91% by the new technology, showing a distinct difference. However, after a gargle, the new technology had low 13%. Additionally, the pontic base made with the existing conventional method showed 71% of chance, the new technology method showed 8% of chance in terms of self-cleansing.

Occluding Effect of the Application of Fluoride Compounds and Desensitizers on Dentinal Tubules (불소도포 및 지각과민처치제 적용 후 상아세관 폐쇄효과와 지속력 평가)

  • Lee, Ye-Jin;Jeong, Moon-Jin;Ahn, Yong-Soon;Cheun, Su-Kyung;Jeong, Soon-Jeong;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.272-283
    • /
    • 2016
  • This study compared and analyzed the occluding effects of fluoride compounds and desensitizers, which are commonly used in dental clinics, on dentinal tubules. This study also evaluated the persistence of the active ingredients over time by performing toothbrushing with an electric toothbrush. Thirty-five molar teeth, which had been extracted within the past 3 months from healthy people without tooth decays, amalgam fillings, or dental crowns, were divided into 4 pieces each. Of these, 135 teeth pieces were used as study specimens. These specimens were divided into a control group, an untreated group, and 5 experimental groups (acidulated fluoride gel, fluoride varnish, Gluma, Super Seal, and SE-Bond). The specimens were then subjected to toothbrushing equivalent to 1 week (140 times), 2 weeks (280 times), and 4 weeks (560 times), and the occluding effects on dentinal tubules in 3 regions of each specimen were examined under a scanning electron microscope. The fluoride varnish treated group showed the highest degree of dentinal tubule occlusion effects during the first, second, and fourth weeks of toothbrushing, with the SE-Bond treated group showing the second highest degree and the Gluma treated group showing the lowest degree. After 4 weeks of toothbrushing, the Gluma treated group and the Super Seal treated group showed the lowest degrees of dentinal tubule occlusion effects. In summary, the fluoride varnish treated group and the SE-Bond treated group displayed higher occlusion effects even after 4 weeks of treatment than did the other experimental groups. Therefore, it is the authors' belief that fluoride varnish and SE-Bond are effective for treating dentinal hyperesthesia.

The Comparison of the Retention of the Full Veneer Casted Gold Crowns with Different Implant Abutment Shapes and Types of Cements (임플란트 지대주 형태와 시멘트 종류에 따른 전부주조금관의 유지력 비교)

  • Jung, Jae-Wook;Kim, Jee-hwan;Kim, Sun-jai;Moon, Hong-suk;Shim, June-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.403-415
    • /
    • 2009
  • The purpose of the study is to establish the effect of different abutment shapes and types of cements on the retention of the full veneer casted gold crowns. Metal dies that has the similar shape with the implant abutment were manufactured using a short(5mm) and long(10mm) dies with different convergence angles. Metal dies and gold crowns, which were made from the metal dies, were cemented with Temp-bond, Temp-bond mixed with petroleum jelly, ZPC and Premier implant cement. After that, these were tested for tensile force at the point of separation. The effect of convergence angle changes of different cement types on the retention was studied as well as the effects of the cement type changes with different convergence angles on the retention. In addition, study about the marginal gap of Premier implant cement used for this experiment was conducted. The results are as followed under the in-vitro experimental limits; 1. The retention of the Temp-bond mixed with petroleum jelly decreased as the convergence angle increased, and the retention was weakest among the cements. 2. The retention of ZPC decreased as convergence angle increased. When convergence angle was 5 degrees, ZPC showed stronger retention than Premier implant cement. 3. Premier implant cement had the weakest retention when the convergence angle was 5 degrees but when the convergence angle was 10 degrees, it had the strongest retention. As the angle increased more than 10 degrees, the retention decreased. 4. Premier implant cement showed bigger marginal gap when the convergence angle was 5 degrees than 10 degrees under the experimental condition.