• 제목/요약/키워드: 치과 보철물

검색결과 814건 처리시간 0.029초

CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구 (A STUDY OF PRECISE FIT OF THE CAM ZIRCONIA ALL-CERAMIC FRAMEWORK)

  • 전미현;전영찬;정창모;임장섭;정희찬
    • 대한치과보철학회지
    • /
    • 제43권5호
    • /
    • pp.611-621
    • /
    • 2005
  • State of problem: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. Purpose: This study was to evaluate the at of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). Material and Method: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesio-distal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of $\times100$. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. Results and Conclusion: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia$(81.9{\mu}m)$ and metal $(81.3{\mu}m)$ framework and internal marginal gaps of zirconia $(44.6{\mu}m)$ were smaller than those of metal framework $(58.6{\mu}m)$. 2. Internal axial gaps of zirconia framework$(96.7{\mu}m)$ were larger than those of metal frame-work$(78.1{\mu}m)$ significantly and adversely, internal occlusal gaps of zirconia frame-work$(89.4{\mu}m)$ were smaller than those of metal framework $(104.9{\mu}m)$ significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.

2종류의 버와 3종류의 버를 이용해 제작된 크라운 보철물의 정밀도 평가 (Precision evaluation of crown prosthesis manufactured by two bur and three bur)

  • 김총명;전진훈;이재준;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제38권2호
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: The purpose of this study was to assess precision of crown prostheses that were fabricated by using 2 kinds of bur or 3 kinds of bur. Methods: The crowns were fabricated by using the first molar of the right maxillary in this study. The abutments that were prepared were scanned by using a scanner and designed by using CAD software. Based on the crown design, NC data were created with CAM software. The created NC data were used while fabricating the crown prostheses by using 5-axis milling machine. Scanning was done for the internal and external surface of the completed crown prostheses and 3-dimensional measurement was conducted for precision assessment. Results: The $RMS{\pm}SD$ value for the external surface of the crown prostheses that was fabricated by using two burs and three burs were $28.5{\pm}4.1{\mu}m$ and $19.1{\pm}2.8{\mu}m$, respectively; and the value for two burs were bigger than that for three burs with statistical significance (p<0.001). The $RMS{\pm}SD$ value for the internal surface of the crown prostheses that was fabricated by using two burs and three burs were $14.9{\pm}1.9{\mu}m$ and $13.3{\pm}2.5{\mu}m$, respectively; and the value for two burs were bigger than that for three burs but with no statistical significance. Conclusion: Based on this study, the prostheses that were fabricated by using 3 bur presented better stability compared to those that were fabricated by using 2 bur and statistically significant difference was found only in the external surface.

임시 수복물 중합시 시간과 중합온도가 변연 적합도에 미치는 효과 (EFFECT OF TIME AND TEMPERATURE ON THE MARGINAL FIT OF PROVISIONAL RESIN CROWN DURING POLYMERIZATION)

  • 윤승환;오남식;김일규;오성섭;최진호;김왕식;임영일
    • 대한치과보철학회지
    • /
    • 제39권5호
    • /
    • pp.514-525
    • /
    • 2001
  • The purpose of this study was to compare the marginal fit of provisional restorations by differentiating the removal time and setting temperature during resin polymerization. After mixing autopolymerizing methyl methacrylate resin, the material was placed in a preformed resin shell crown. The crown was seated on a die with 1mm shoulder margin. Crowns were removed after 3, 4, 5, 6 minutes and polymerization was continued under the following conditions : $25^{\circ}C$ air, $30^{\circ}C,\;40^{\circ}C,\;50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$ water. After polymerization. the crown was sectioned. The marginal & occlusal discrepancies were measured. The mean marginal discrelpancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $96.6{\mu}m.\;84.6{\mu}m,\;86.7{\mu}m$ and $105.6{\mu}m$. The mean occlusal discrepancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $106.7{\mu}m,\;89.3{\mu}m,\;98.6{\mu}m$ and $127.7{\mu}m$. There was significant difference between 4 minutes group and 6 minutes group in occlusal discrepancies. The mean marginal & occlusal discrepancies for crowns polymerized in $25^{\circ}C$ air were $98.2{\mu}m$ and $124.1{\mu}m$. The crowns polymerized in $50^{\circ}C$ water demonstrated the smallest marginal & occlusal. discrepancies. The mean value of marginal & occlusal discrepancies in $50^{\circ}C$ water were $73.1{\mu}m$ and $77.5{\mu}m$. These values were smaller than that of $25^{\circ}C$ air. There were significant differences in the occlusal discrepancies between $25^{\circ}C$ air and water conditions of $50^{\circ}C$ water (${\alpha}=0.05$) but. no significant difference in marginal discrepancies. There was no significant difference in the interaction between time and temperature. 4 minutes waiting time & $50^{\circ}C$ water polymerizing condition produces the best fit at the margin of the provisional crown.

  • PDF

금속하부구조물이 도재의 색조에 미치는 영향에 대한 분광측색분석 (SPECTROPHOTOMETRIC ANALYSIS OF THE INFLUENCE OF METAL SUBSTRATE ON THE COLOR OF CERAMIC)

  • 이수옥;우이형;최대균;권긍록
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.148-159
    • /
    • 2003
  • Statement of problem Metal-ceramic restorations have been used extensively by dental clinicians for nearly 40 years. Strength an functional ability of metal-ceramic restorations are proved to be satisfying, However esthetics and biocompatibility of metal alloy which is used in metal-ceramic restoration is not ideal. Using pure gold as an alternative, have advantage of esthetics, biocompatibility over conventional metal alloy. But there had been little article which studied on the color effect of pure gold on fual porcelain color. Purpose The purpose of this study was to spectrophotometrically evaluate the difference between color of metal alloy(Au-Pt, Ni-Cr) and pure gold, during color masking procedure with opaque porcelain and to analyze the differences, Material and Methods Three types of metal - base metal(Ni-Cr), high gold alloy(Au-Pt), pure gold(GES) - specimen were fabricated 1cm in diameter. Four steps were established - after finishing, after pre-coditioning, after application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness)- and tested color with spectrophotometer every each steps and analyzed with $CIEL^*a^*b^*$ color order system. One-Way ANOVA test was used to and out if there were significant differences between groups tested and Shaffe multiple comparison was used to identify where the differences were. Results 1. After finishing and pre-conditioning, pure gold(GES) group showed most high values in $L^*,a^*,b^*$. 2. After application of first opaque porcelain(0.08mm in thickness), after application of second opaque porcelain(0.15mm in thickness), pure gold(GES) group showed the least difference in $L^*,a^*,b^*$ values and the lowest ${\Delta}E$ value(${\Delta}E$=0.63). 3. After application of first opaque porcelain and after application of second opaque porcelain differences that were significant (P<0.05) between groups were found only in $a^*$ values. 4. Base metal alloy group showed the lowest $a^*$ value in test after application of first opaque porcelain and the highest value in test after application of first opaque porcelain Conclusion Pure gold group and high gold group showed higher $a^*$ values than base metal group when tested after 0.08mm thickness of opaque porcelain was applied and pure gold group showed much similar $L^*,a^*,b^*$ values between 0.08mm thickness and 0.15mm thickness of opaque porcelain. This meant that pure gold was more easily masked by opaque porcelain than the other two groups.

식용색소에 의한 CEROMER 수복물의 색안정성 (COLOR STABILITY OF CEROMERS IN THREE FOOD COLORANTS)

  • 정유진;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.136-147
    • /
    • 2003
  • Statement of problem : Ceramic and composite resin have been used to fulfill the demand for esthetic prosthesis. However, ceramic is easy to break and wears off the opposite natural teeth. Conventional composite resin also has low abrasive resistance and color stability. Ceramic Optimized Polymer (ceromer) was developed in mid-1990s to overcome the shortfalls of ceramic and composite resin. Ceromer has similar abrasiveness with the natural tooth and has relatively high strength. Color stability affects esthetics and long-term prognosis of the prosthesis. Purpose The purpose of this study was to compare color stability of ceromers(2 types : $Artglass^{(R)}$. $Targis^{(R)}$) with ceramics ($Vintage^{(R)}$-polishing, $Vintage^{(R)}$-glazing). Material and Method : The color difference(${\Delta}E^*$) was measured by spectrophotometer with different immersion time. Twenty disks, 3mm in thickness and 10mm in diameter, were fabricated for each specimen in shade A2(Vita Lumin shade guide), Specimens (5 samples in each group) were immersed in the food colorants (Red no.3. Yellow no.4, Blue no.1, Distilled water) for 24 hours, 48 hours and 72 hours respectively. $L^*,\;a^*$ and $b^*$ value were measured with spectrophotometer (CM 503i : Minolta Co., Japan) and mean ${\Delta}E^*$ value was calculated for statistical analysis Results : The results of this study were obtained as follows. 1. The ${\Delta}E^*$ values of all test samples increased with the time of immersion. 2. The ${\Delta}E^*$ values of all materials increased in order of Distilled Water, Yellow no.4, Blue no.1 and fed no.3. There was significant difference between Red no.3 and the other food colorants(p<0.05). 3. The ${\Delta}E^*$ values increased in order of $Vintage^{(R)}$-glazing, $Vintage^{(R)}$-polishing. $Artglass^{(R)}$ and $Targis^{(R)}$. There was significant difference between $Vintage^{(R)}$-glazing and the other materials (p<0.05). Conclusion : By means of the above results, immersion time was found to be a critical factor for color stability of ceromer. For the long-term color stability of prosthesis it is recommended patients having ceromer prosthesis ($Artglass^{(R)},\;Targis^{(R)}$) to reduce the habitual intake of Red no.3 colorants con taming foods.

복합레진으로 제작한 인레이 보철물 구조에 따른 교합면 부위의 2차원 변연 적합도 및 내면 부위의 3차원 정확성 분석 (Analysis of the 2-dimensional marginal fit of the occlusal surface and the 3-dimensional accuracy of the inner surface of the occlusal surface according to the inlay prosthesis structure made of composite resin)

  • 김동연;이태희;박동인;박진영;정일도;이하나;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제41권1호
    • /
    • pp.21-27
    • /
    • 2019
  • Purpose: To evaluate 2D and 3D of occulsal, mesial-occlusal and mesial-occlusal-distal cavity of composite resin inlay. Methods: Abutment tooth 16, 36 of FDI system was selected for the study. Inlay prostheses classified as occlusal cavity (OC group), mesial-occlusal (MOC) and mesial-occlusal-distal cavity (MODC) were prepared using composite resin. Composite resin was injected with composite resin in prepared tooth cavity and then photopolymerized with UV light. Additional thermal polymerization was performed. Marginal gap of composite resin inlays were measured by digital microscope(x160) with silicone replica technique. The data was analyzed from statistical software for Kruskal-Wallis test (${\alpha}=0.05$). 3-dimensional analysis was analyzed through superimposition method. Results: The smallest 2D marginal fit measure of the three groups was $47.0{\pm}21.6{\mu}m$ in the MOC group. The largest 2D marginal was $69.1{\pm}33.8{\mu}m$ in the MODC group. In the trueness of the three groups, the most accurate figure was $14.4{\pm}2.3{\mu}m$ for the MODC group. In Precision, the most accurate figure was $14.5{\pm}4.3{\mu}m$ for the MODC group. Conclusion : In this study, 2D marginal fit of OC, MOC, and MODC cavities fabricated with composite resin was applicable to all clinical applications. In the 3D inner surface accuracy evaluation, the MODC group showed the accuracy results.

교합학 교과목 완전학습을 위한 개인별 취약단원 진단 및 보완 교수.학습 방법 (A Teaching Method of Detecting and Improving Individual Weakpoints in the Course of Occlusion)

  • 박혜숙
    • Journal of Oral Medicine and Pain
    • /
    • 제35권1호
    • /
    • pp.1-18
    • /
    • 2010
  • 치기공과의 1학년에 개설된 교합학 개론은 치과기공에서 가장 기본이 되는 과목으로 2,3학년에서 배우게 되는 보철 및 교정 치과기공에 관련된 임상전공과목의 기초가 될 뿐 아니라 수직 수평적 연관성을 가지고 있다. 따라서 학생들이 이 과목의 어느 단원에서 이해하지 못하는 부분을 보완하지 못하고 넘어가 버리면 다른 치과기공 관련 과목의 일정 부분을 이해하는데 어려움을 겪을 수 있다. 이에 저자는 교육평가에 C-언어 컴퓨터 프로그램을 설계하여 학생마다의 취약단원을 진단해서 알려주고 그 부분을 집중 반복 학습하도록 하여 완전학습을 구현하는 교수 학습법을 개발하였다. 각 단원의 세부항목에서 출제한 형성평가를 실시하여 채점한 후, 개발한 C-언어 컴퓨터 프로그램에 각 학생의 틀린 문항을 입력하여 문항의 출처단원이 나타나면 이것을 각각 출력하여 학생에게 나누어 준다. 학생은 그 부분을 스스로 학습해서 다음 주 수업시간에 파워포인트로 발표하고 보고서를 제출한다. 틀린 문제가 많으면 학습량이 많아지고, 극단적으로 틀린 문제가 없으면 과제물도 없으므로 형성평가 대비를 철저히 할 수 있는 동기를 유발한다. 결국 시험 다음 주 수업시간에 거의 모든 학생들이 과제물을 발표하게 되어 거의 모든 문항에 대해 복습하는 효과를 가져 완전학습이 되도록 한다. 또한 학생들이 많이 틀리는 단원을 교수자도 알게 되어 그 원인을 분석하여 다음 해의 수업에서 그 단원에 대한 수업의 질을 높이는 계기가 된다. 대부분의 학생들은 특정 과목에서 자신의 취약 단원이 어디인지를 모르거나 혹은 알더라도 그 곳을 해결하지 않은채 그냥 넘어가는 경우가 많다. 따라서 다른 전공교과목간의 수직 수평 연계성이 강해서 반드시 일정 수준 이상의 학업성취가 요구되는 교과목에 본 교수 학습 모형을 선별적으로 적용하면 평균적인 학생이 완전학습에 도달하리라 사료된다.

치과용 복합레진으로 수리된 CAD-CAM hybrid 수복물의 전단결합강도 (Shear bond strength of dental CAD-CAM hybrid restorative materials repaired with composite resin)

  • 문윤희;이종혁;이명구
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.193-202
    • /
    • 2016
  • 목적: 본 연구에서는 치과용 CAD-CAM (computer aided design-computer aided manufacturing) hybrid 수복재료인 LAVA Ultimate와 VITA ENAMIC을 광중합 복합레진을 사용하여 수리할 때 표면처리방법(grinding, air abrasion with aluminum oxide, HF acid)과 접착재료(Adper Single Bond 2, Single Bond Universal)의 종류가 두 재료 사이의 전단결합강도에 어떠한 영향을 미치는지 알아보고자 하였다. 재료 및 방법: LAVA Ultimate와 VITA ENAMIC 시편을 30일간 $37^{\circ}C$의 인공타액(Xerova solution)에 보관하여 시효처리를 실시한 후 각각 SiC paper grinding한 것, grinding 후 air abrasion처리를 추가한 것, grinding 후 HF 처리한 것으로 분류하고 각각 no bonding, Adper Single Bond 2, 또는, Single Bond Universal 도포로 세분하여 9개의 group, 총 18개의 subgroup으로 나누어 실험을 실시하였다(N=10). HF 처리group에서는 도재시편을 대조군으로 추가하였다(N=10). 표면 처리 후 광중합 복합레진(Filtek Z250)을 각각의 시편에 부착하고 이를 1주일간 실온의 물에 침적시켰고 이후 전단결합강도를 측정하고 파절양상 및 표면처리 효과를 SEM으로 확인하였다. One-way ANOVA를 이용하여 group 간의 유의성을 분석하였고 사후 분석으로 Scheffe test를 실시하였다(${\alpha}=.05$). 결과: 실험 결과 접착재료 처리를 한 group들이 접착재료 처리를 하지 않은 group에 비해 모든 표면처리에서 더 높은 전단결합력을 나타내었으며, 표면처리만 시행한 group에서는 aluminum oxide air abrasion이 전단결합력의 증가에 약간의 영향을 미치는 것으로 나타났으나 통계적 유의성은 보이지 않았다. 결론: LAVA Ultimate와 VITA ENAMIC의 두 재료를 광중합 복합레진을 이용하여 수리를 실시할 경우 각각의 재료에 적합한 표면처리방법과 접착재료의 선택에 대한 연구가 더 필요할 것으로 사료된다. 특히 LAVA Ultimate의 경우 접착재료의 사용은 추천된다고 사료되었다.

치과용 레진 시멘트의 중합 수축률 특성에 관한 연구 (In vitro study of Polymerization shrinkage-strain kinetics of dental resin cements)

  • 김태훈;양재호;이재봉;한중석;김성훈
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.55-60
    • /
    • 2010
  • 연구 목적: 치과용 레진시멘트의 중합 수축은 수복물이 치아에 정확하게 합착되는 것을 방해하고, 내부 응력의 원인이 되어 치아에 여러 문제점을 일으킬 수 있다. 이러한 임상적인 문제점을 줄이기 위해서 사용하는 치과용 레진시멘트의 중합 수축률에 대해 아는 것이 중요하다. 본 연구에서는 상업적으로 이용되고 있는 몇 가지 레진시멘트의 시간에 따른 중합 수축률을 측정, 서로 비교하고자 하였다. 연구 재료 및 방법: 3종류의 자가 중합형 레진시멘트(Fujicem, Superbond, M bond)와 3종류의 이원 중합형 레진시멘트(Maxcem, Panavia F, Variolink II) 별로 각각 5개의 시편을 이용하였다. 각 재료의 중합 수축률은 Bonded disk method를 이용하여 측정하였다. 안쪽 직경 16 mm, 두께 1 mm 의 동으로 제작된 링을 유리판 ($74\;mm\;{\times}\;25\;mm\;{\times}\;3\;mm$) 위의 중앙에 위치시켜 부착하고, 그 유리판 중앙에 실험 재료를 구 형태로 만들어 올리고, 다른 유리판으로 눌러서 원판 형태 (직경 8 mm, 두께 1 mm)의 시편을 제작하였다. 시편의 중합 수축률은 재료가 중합이 시작된 후 120분동안, $23^{\circ}C$에서 측정하였다. 시간에 따른 수축량에 대한 kinetics curve를얻고, 각 실험 재료의 수축률의 평균값 (%)과 표준편차를 구한 뒤, one-way ANOVA 및 Scheffe post hoc test를 유의수준 0.05 에서 처리하여 그 결과 값을 비교하였다. 결과: 1. 실험에 사용된 Fujicem, Maxcem, M bond, Panavia F, Superbond, Variolink II 은 중합이 시작 된 120 분 후의 중합 수축률이 각각 3.72%, 4.19%, 4.13%, 2.44%, 7.57%, 2.90%의 값을 보였다. 2. Panavia F가 중합 수축률이 가장 작았고, Superbond가 중합 수축률이 가장 컸다 (P<.05). 3. Maxcem 과 M Bond 간에는 유의한 차이가 없었다 (P>.05). 4. 6종류의 레진 시멘트에서 90% 이상의 대부분의 수축은 중합이 개시된 30분 내에 거의 일어났다. 결론: 자가 중합형 레진시멘트의 혼합 후 나타나는 중합 수축이 이원 중합형 레진시멘트보다 천천히 일어나지만, 혼합 120분 뒤의 중합 수축은 이원 중합형 레진 시멘트 보다 유의할 정도로 높았다. 치과용 레진시멘트의 중합 수축은 혼합한 후 30 분내에 대부분 일어난다.

일부 노인의 저작강도별 음식섭취능력과 잔존치아수가 구강건강관련 삶의 질에 미치는 영향 (Influence of the Food Intake Ability and the Number of Remaining Teeth on Oral Health Related Quality of Life in Some Elderly People)

  • 김다혜;황수정
    • 치위생과학회지
    • /
    • 제16권1호
    • /
    • pp.53-61
    • /
    • 2016
  • 이번 연구는 2009년 4월부터 9월까지 대전 동구보건소에서 실시하는 노인 스케일링-불소도포 사업에 참여한 노인 503명을 대상으로 잔존치아수와 강도별 30가지 음식섭취 능력, 구강건강관련 삶의 질(OHIP-14)의 관계를 조사하였다. 그 결과, 음식섭취능력에 따른 총 잔존치아수는 모든 음식을 섭취할 수 있는 1군 $21.78{\pm}8.27$개, 26가지 음식을 섭취할 수 있는 2군 $16.75{\pm}7.87$개, 16가지 음식을 섭취할 수 있는 3군 $14.68{\pm}9.77$개, 8가지 음식을 섭취할 수 있는 4군 $9.93{\pm}8.13$개, 모든 음식을 섭취할 수 없는 5군 $10.18{\pm}8.37$개로 1군, 2~3군, 4~5군 간의 유의한 차이가 있었다. 보철 포함 대합구치수는 1군 $2.80{\pm}2.63$개, 2군 $2.16{\pm}2.44$개, 3군 $1.73{\pm}2.30$개, 4군 $0.78{\pm}1.68$개, 5군은 $0.51{\pm}1.22$개으로 1, 2군과 5군의 유의한 차이가 있어서 고정성 보철물을 포함한 대합구치는 음식섭취능력에 유의한 영향을 미쳤다. OHIP-14는 1군 $2.16{\pm}3.37$, 2군 $4.35{\pm}6.09$, 3군 $7.23{\pm}7.53$, 4군 $11.20{\pm}3.40$, 5군 $18.15{\pm}8.55$으로 모든 군 간 유의한 차이가 있고 음식섭취능력이 좋을수록 구강건강관련 삶의 질이 양호하였다. 강도별 음식섭취능력과 잔존치아수가 OHIP-14에 미치는 영향을 분석한 결과, 단단한 음식 섭취능력은 OHIP-14에 유의한 영향이 없었으며 중강도 음식섭취능력, 무른 음식 섭취능력 총 잔존치아수 순으로 OHIP-14에 영향을 미쳤다. OHIP-14와 음식의 상관관계는 참외(-0.701), 삶은 닭(-0.664), 사과(-0.659), 우엉조림(-0.632), 배추김치(-0.626), 양갱(-0.624), 오이소박이(-0.618), 삼겹살(-0.618), 갈비찜(-0.615), 생선조림(-0.603) 순으로 강한 음의 관계를 나타내었다. 따라서, 노인의 구강건강 삶의 질 유지와 향상을 위해 21개 이상의 자연치아를 유지하고 자연치아가 상실된 경우 육류와 채소, 과일류를 충분히 섭취할 수 있도록 고정성 보철물 수복이 필요하며 이를 위한 적절한 노인 구강보건사업과 치과 건강보험정책이 고려되어야 할 것이다.