• Title/Summary/Keyword: 치과 보철물

Search Result 814, Processing Time 0.031 seconds

Interproximal contact loss between implant-supported prostheses: a clinical report (임플란트 고정성 보철물 사이에서의 인접면 접촉상실: 증례보고)

  • Yeon-Hee Park;Kyoung-A Kim;Jung-Jin Lee;Jae-Min Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.47-53
    • /
    • 2024
  • Interproximal contact loss (ICL) is the most frequent complication in partially edentulous patients treated with implant-supported prostheses. However, in most cases, ICL occurs between the implant prosthesis and the natural tooth due to the movement of the natural tooth. There are several causes of ICL that occur between an implant prosthesis and a natural tooth. There are only a few reported cases of ICL occurring between implant prostheses, and explaining the causes of ICL between implant prostheses and natural teeth is challenging. This clinical report describes cases of ICL between implant prostheses and discusses its causes and countermeasures.

The Prevention and Treatment of Gingival and periodontal Diease Related to Dental Restorations (보철물 장착으로 인하여 야기되는 치주질환의 예방과 처치)

  • Han, Su-Bu
    • The Journal of the Korean dental association
    • /
    • v.22 no.8 s.183
    • /
    • pp.667-670
    • /
    • 1984
  • 보철물이 제기능을 발휘하기 위해서는 건강한 치주조직이 필요할 분 아니라, 보철물 그 자체가 건강한 치주조직을 계속적으로 유지시켜 줄 수 있어야 한다. 보철물이 치주질환을 야기하거나, 치주질환을 가진 지대치에 아무런 처치없이 보철물을 장착한다면 결국 치아의 상실을 초래하게 된다. 이런 일로 인하여 외국에서는 치과이사와 환자가 소송에까지 이르게 되는 불행한 에가 많다. 이런 예는 먼 나라의 이야기가 아니라, 우리 나라에서도 문제가 되어가고 있는 것 같다. 필자의 조사(미 발표)에 의하면, 보철물이 치주조직에 미치는 영향에 관하여 재 조명이 있어야 될것으로 생각한다.

  • PDF

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.

Clinical cases of implant-supported fixed dental prosthesis using modified lingual screw system (T-screw system) (개선된 설측 고정 나사 시스템(T-screw system)을 이용한 임플란트 보철 수복 증례)

  • Hong, Tae-Young;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.423-430
    • /
    • 2016
  • The implant prosthesis can be divided into the screw retained prosthesis and cement retained prosthesis. Each type has advantages as well as disadvantages which is unfavorable to maintain the implants. To overcome these drawbacks, T-screw system was developed. T-screw system which utilizes a lingual direction of the screw to retain the implant prosthesis, has advantages of retrievability of the prosthesis, passive fit, and possibility to form esthetic and functional occlusal surface. The prior prosthesis which utilized horizontal screws had difficulty in fabrication especially in the case of multiple units, and also limited use with all-ceramic prosthesis. In this case, fabricating the implant prosthesis by using the T-screw system showed superior results in easy maintenance, esthetics, and also functions. In addition, we are to report the method of using the T-screw system in implant prosthesis, such as multiple units of implant prosthesis and all ceramic prosthesis.

Korea Academy of Prosthodontics criteria for longevity studies of dental prostheses (보철물 수명 연구를 위한 대한치과보철학회 표준 방안: KAP Criteria)

  • Yoon, Joon-Ho;Park, Young-Bum;Youn, Seung-Hwan;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.341-353
    • /
    • 2016
  • Purpose: The most important factor in longevity studies of dental prostheses is objective and consistent evaluation of the prosthesis. The Korean Academy of Prosthodontics suggested developing a standardized method for longevity studies of dental prostheses. The purpose of this study is to evaluate previously-used criteria and to develop new criteria, in the form of a procedure flowchart and an evaluation sheet. These new criteria may be able to provide a unified standard for future longevity studies of dental prostheses. Materials and methods: A literature review was performed about the evaluation of dental prostheses. Taking into account the strengths and weaknesses of previously used criteria, a novel, intuitive and objective method was developed for assessment of dental prostheses. Then, a pilot survey was performed with the newly developed flowchart and evaluation sheet to determine problems and implement possible improvements. Results: Thirty cases of fixed dental prosthesis (FDP), 25 cases of removable dental prosthesis (RDP), and 13 cases of implant supported prosthesis (ISP) were evaluated. The average life expectancy estimate was 12.82 years for FDP, 5.96 years for RDP, and 4.82 years for ISP with Kaplan-Meier survival analysis. Additionally, possible improvements discovered by the pilot survey were reflected in the flowchart and evaluation sheet. Conclusion: The newly developed KAP criteria, flowchart and evaluation sheet enabled objective and consistent results in trial longevity studies of dental prostheses. It is expected that future studies will not only use the KAP criteria but also further improvement will be made on them.

Web viewer for sharing of prosthesis design between laboratory and clinic: Case report (웹뷰어를 이용한 기공실과 진료실 측 간의 보철물 설계 형태의 공유: 증례 보고)

  • Jang, Sung Won;Lee, Ho Jin;Kim, So-Yeun;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.276-282
    • /
    • 2022
  • Close communication between clinicians and dental technicians is an important factor in providing successful prostheses. The exchange of opinions with laboratories has mainly been in the form of written prescriptions and a photos, but it has been reported that information transmission may be limited. Currently, as digital technology-based prosthesis fabrication is common, 3D image objects can be stored on the web and can be easily viewed through a mobile web browser. In this article, we introduce cases where the design of the prosthesis was improved by designing the prosthesis using CAD software and reviewing the prosthesis designed with the clinical side through a web viewer. Through this protocol, it was possible to improve the occlusal surface and crown contour, the opposing teeth condition, the size of the gingival embrasure, and the shape of pontic. The process of sharing, discussing, and modifying the prosthesis design with the clinician and technician through a web viewer contributes to reflecting the diversity of oral conditions and individualized needs, thereby helping to make functional and esthetic prostheses.

Restoration of anterior teeth with dental implant using multilayer zirconia (다층 지르코니아를 이용한 임플란트 전치부 수복 증례)

  • Lee, Sunghee;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.469-477
    • /
    • 2021
  • For successful restoration of maxillary anterior implants, both pink esthetics and white esthetics must be satisfied. For pink esthetic part, the role of appropriate provisional prosthesis restoration is important, and for white esthetic part, the color and shape of the definitive prosthesis is important. Multilayer zirconia can be used for natural tooth appearance due to the higher transparency of the incisal area compared to the conventional monolithic zirconia. Therefore, in this case, white esthetic part was achieved through multilayer zirconia after recovering function and esthetics through appropriate provisional prosthesis in a patient who lost the maxillary anterior teeth.

An efficient way of communication between dentists and dental technicians to ensure optimum clinical outcome with implant restorations (임플란트 보철물 제작시 치과의사와 기공사가 효과적으로 소통하는 한가지 방법)

  • Kim, Chonghwa
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.66-74
    • /
    • 2020
  • Communication and cooperation between dentists and dental technicians are two essential elements for the fabrication of high quality 'custom' prosthesis. For successful communication and cooperation between the two groups, however, dentists and dental technicians must share common understanding about clinical dentistry. Ironically, it is often noticed that they are not really sharing the same clinical knowledge. Although there is a strong association between 'Emergence Profile' of implant prostheses and periodontal health or esthetics, no definite guideline has ever been provided for ideal emergence profile of implant prosthesis in literature. Problems resulted from inherent differences between implants and natural teeth must be acknowledged and shared between dentists and dental technicians so that they can come up with desirable clinical results with implant prostheses.

Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: A case report (심미보철 수복을 위한 3차원 안면스캔과 가상 보철물 시각화를 이용한 디지털 치료 증례)

  • Mai, Hai Yen;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.425-431
    • /
    • 2019
  • This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.