IN VITRO EVALUATION OF ACCURACY AND CONSISTENCY OF FOUR DIFFERENT ELECTRONIC APEX LOCATORS (4종 전자근관장측정기의 정확성과 일관성에 관한 in vitro 연구)

  • Cho, Jae-Hyun;Kum, Kee-Yeon;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.390-397
    • /
    • 2006
  • The purpose of this study was to evaluate the accuracy and the consistency of four different electronic apex locators in an in vitro model. Fourty extracted premolars were used for the study. Four electronic apex locators (EAL) were Root ZX, Smarpex, Elements Diagnostic Unit (EDU), and E-Magic Finder Deluxe (EMF). After access preparation, the teeth were embedded in an alginate model and the length measurements were carried out at '0.5' and 'Apex' mark using four EALs. The file was cemented at the location of the manufacturers' instruction (Root ZX, EDU, EMF: 0.5 mark, SmarPex: Apex mark). The apical 4mm of the apex was exposed and the distance from the file tip to the major foramen was measured by Image ProPlus (${\times}100$). The distance from the file tip to the major foramen was calculated at 0.5 and Apex mark and the consistency of 0.5 and Apex mark was compared by SD and Quartile of Box plots. In this study, Root ZX and EMF located the apical constriction accurately within ${\pm}0.5 mm$ in 100%, whereas SmarPex and EDU located in 90% and in 70% respectively. For Root ZX and EMF, there was no significant difference between the consistency of 0.5 and Apex mark. However, for the EDU and SmarPex, Apex mark was more consistent than 0.5 mark. From the evaluation of the consistency in this study, for Root ZX and EMF, both 0.5 and Apex mark can be used as a standard mark. And for EDU and SmarPex, the Apex mark can be recommended to be used as a standard mark.

A Clinical Study about Effectiveness of Essential Oil-Containing Dental Paste in Controlling Oral Malodor (아로마 함유 치약이 구취에 미치는 영향에 관한 임상적 연구)

  • Jeon, Lee-Sun;Kang, Soo-Kyung;Chun, Yang-Hyun;Hong, Jung-Pyo
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.141-148
    • /
    • 2005
  • Since many reports for the influence of the essential oils on the oral microorganism were presented, it is important to use the essential oils in clinical field. At the present day which emphasized the quality of life, oral malodor is one of the serious problems, so we need to try to decrease of oral malodor. This study was designed to make on evidence of the effect of essential oils to oral malodor clinically and to develop on effective treatment for oral malodor by using the dental paste which contains essential oils. 40 dental students volunteered to participate in this study and double blind test was used. At the beginning, all subjects were measured their morning malodor prior to this experiment, at the 3cm posterior to their incisal edge of the oral cavity by Halimeter(Interscan Co. Chatsworth, CA). After that we divided the students in half into two groups A and B. We have supplied different tooth pastes, dental paste A and B, to two groups respectively. The dental paste B contained essential oils which are tea tree, lemon and peppermint. All students used different tooth pastes everyday for 3 weeks. And all students were measured their morning malodor every week with the same method by using Halimeter. This study was resulted that ; 1. The dental paste which contains essential oils has continuously decreased the morning malodor during the whole period of experiments. 2. The number of students with increase in their morning malodor was generally decreased in the group B who used the toothpaste which contains essential oils, compared with the group A who used the toothpaste which didn't contain essential oils on the 2nd and 3rd week of the experiment. 3. In the group B, the average data on increasing rate of morning malodor was less than in the group A. 4. In the 2nd and 3rd week of the experiment, the data on the rate of morning malodor of the group B was generally decreased continuously compared with the group A. These results have statistically significance under 95% confidence interval of the difference.(p$\leq$0.05) As the result, the toothpaste which was containing essential oils was effective in decreasing the morning malodor.

CLINICAL STUDY OF SHADE IMPROVEMENT AND SAFETY OF POLYMER-BASED PEN TYPE BlancTis Forte WHITENING AGENT CONTAINING 8.3% CARBAMIDE PEROXIDE (8.3% Carbamide Peroxide 함유 펜 형 자가미백제인 BlancTis Forte의 색조개선 및 안전성에 관한 임상연구)

  • Lee, Jin-Kyung;Min, Sun-Hong;Hong, Sung-Tae;Oh, So-Ram;Chung, Shin-Hye;Hwang, Young-Hye;You, Sung-Yeop;Bae, Kwang-Shik;Baek, Seung-Ho;Lee, Woo-Cheol;Son, Won-Jun;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.154-161
    • /
    • 2009
  • This clinical study evaluated the whitening effect and safety of polymer based-pen type BlancTis Forte (NIBEC) containing 8.3% carbamide peroxide. Twenty volunteers used the BlancTis Forte whitening agent for 2 hours twice a day for 4 weeks. As a control. Whitening Effect Pen (LG) containing 3% hydrogen peroxide was used by 20 volunteers using the same protocol. The change in shade (${\Delta}E^*$, color difference) was measured using $Shadepilot^{TM}$ (DeguDent) before, during, and after bleaching (2 weeks, 4 weeks, and post-bleaching 4 weeks). A clinical examination for any side effects (tooth hypersensitivity or soft tissue complications) was also performed at each check-up. The following results were obtained. 1. Both the experimental and control groups displayed a noticeable change in shade (${\Delta}E$) of over 2. No significant differences were found between the two groups (p > 0.05), implying that the two agents have a similar whitening effect.2. The whitening effect was mainly due to changes in a and b values rather than in L value (brightness). The experimental group showed a significantly higher change in b value, thus yellow shade, than the control (p < 0.05). 3. None of the participants complained of tooth hypersensitivity or soft tissue complications, confirming the safety of both whitening agents.

OPACITY AND MASHING EFFECT OF THE OPAQUE SHADE COMPOSITE RESINS (Opaque shade 복합레진의 opacity와 배경 색상 차단 능력의 평가)

  • Park, Su-Jung;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.356-364
    • /
    • 2007
  • The purpose of this study was to assess the background color-interceptive ability ana opacity of opaque shade composites (Universal composite, Filtek Z350, Charisma, Clearfil ST, Palpaque Estelite, Esthet-X, and Metafil Flo). Twenty four background specimens (diameter 5.5 mm, thickness 3.0 mm) with Root dentin Mustard (Bisco, Schaumburg, IL, USA) were made. The CIE $L^*a^*b^*$ value of background specimens was measured by a spectrophotometer (Spectrolino, GretagMacbeth, Regensdorf, Switzerland). Three specimens in every group were filled on the background specimens. The surface color of samples was measured by a spectrophotometer in 3.0 mm and every thickness to 0.5 mm while grinding. The color difference in the background color along with 3.0 mm specimen gauged the masking effect in each thickness while grinding and polishing. The opacity was calculated in 1 mm thick specimens. The opacity was in the decreasing order of Clearfil ST, Metafil Flo, Filtek Z350, Palpaque Estelite, Universal composite, Charisma, and Esthet-X (p < 0.05). As the thickness get reduced, $L^*$ value showed decreasing, $a^*$ increasing tendency. The surface color difference between pair of the 3.0 mm thick specimen and after grinding in same opaque resin was above 3.3 except Clearfil ST and Metafil Flo. The color difference (${\Delta}E^*$) between pair of background specimen and opaque resin built-up specimen showed more than 10.0 regardless kinds and thickness. The variance in opacity characteristics and color of the opaque composites is dependent upon manufacturer. When using the opaque resin, the optical properties of each material must be considered as well as cavity.

THE EFFECT OF ND:YAG LASER IRRADIATION ON THE FORMATION OF CALCIUM FLUORIDE AND ACID RESISTANCE OF TOOTH ENAMEL (Nd:YAG 레이저 조사가 Calcium Fluoride 형성 및 치아 내산성에 미치는 영향)

  • Lee, Jae-Ho;Sohn, Heung-Kyu;Kim, Seong-Oh;Park, Kwang-Kyun;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.377-398
    • /
    • 1999
  • Calcium fluoride, created by topical fluoride application, is the reservoir for fluoride ion regulated by pH in the oral environment. Therefore, the amount and the maintenance of calcium fluoride have an important role in preventing dental caries. The aim of this study is to evaluate the effect of Nd:YAG laser irradiation on the generation of calcium fluoride and the acid resistance of tooth enamel. The bovine anterior permanent teeth were prepared (n=276), and divided into following groups : no treatment (control) fluoride application alone, laser irradiation alone, laser irradiation after fluoride application, and fluoride application after laser irradiation. And each group was subdivided based on the application time of 1.23% acidulated phosphate fluoride (APF) (5 min and 30 min) and the irradiation energy of Nd:YAG laser ($20J/cm^2\;and\;40J/cm^2$). In case of fluoride application, each group was divided according to KOH treatment. Twenty three treatment conditions were made for this experiment and twelve specimens were assigned to each treatment condition. In each treatment condition, ten specimens were used for chemical analysis and two specimens were observed under SEM. In groups without treating KOH, fluoride content and the depth of enamel dissolved were measured using enamel biopsy technique. In groups with treating KOH, the amount of calcium fluoride was measured by the treatment with 1 M KOH for 24 hours and enamel biopsy was performed after KOH treatment. The results were analyzed by the fluoride content and the depth of enamel dissolved by enamel biopsy, amount and thickness of calcium fluoride, and the surface structures of enamel. The results are as follows: 1. In groups without treating KOH, the fluoride content of removed enamel showed a positive relationship with the energy density of laser when the laser irradiated before fluoride application 2. In groups without treating KOH, the depth of enamel dissolved decreased more with the combined laser and fluoride treatment than with laser or fluoride treatment, except for the case of $20J/cm^2$ laser irradiation after 5 minute fluoride application (p<0.05). 3. The amount of calcium fluoride did not increased by laser treatment with no statistical significance(p>0.05). 4. The particle size of calcium fluoride increased in case of fluoride treatment after laser irradiation, compared with fluoride application alone. In case of laser treatment after fluoride application, the particle size of calcium fluoride increased and some of the particles fused as well. 5. There were no significant differences in the fluoride content of dissolved enamel between groups without treating KOH and control group, except for the case of laser irradiation after treatment of APF for 30 minutes (p>0.05). 6. In groups with treating KOH, depth of removed enamel in the groups of combined treatment with laser and fluoride was shallower than that in fluoride application groups (p<0.05). 7. In groups without treating KOH, the relationship between fluoride content and the depth of enamel dissolved showed more negative (Spearman correlation coefficient: -0.6281) than in groups with treating KOH (Spearman correlation coefficient: -0.3792). The greater amount of calcium fluoride could be found in case where there was a significant differences of the depth of enamel dissolved between groups with and without treating KOH. From these results, it can be concluded that laser seems to be a little effects on the amount of calcium fluoride formation, but has some effect on the lowering the solubility of calcium fluoride. As the combined treatment of laser and fluoride application showed more effective acid-resistant property, more extended recall period for fluoride application can be achieved with this combined treatment in the clinic.

  • PDF

The effects of fluoride releasing orthodontic sealants on the prevention and the progressive inhibition of enamel demiheralization in vitro (광중합형 및 자가중합형 교정용 전색제의 치아우식예방 및 진행억제효과에 관한 실험적 연구)

  • Chae, Seung-Won;Cho, Jae-O;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.6 s.65
    • /
    • pp.979-995
    • /
    • 1997
  • The purpose of this study was to identify the preventive and the progressive inhibitory effects of enamel demineralization with fluoride releasing light-and self-cured orthodontic sealants(FluoroBond), in vitro, under the polarizing light microscope and the scanning electon microscope. The polarizing light microscopic group was subdivided into seven groups(Group A-Group G). The scanning electron microscopic group was also subdivided into seven groups(Group A'-Goup G'). For polarizing light microscopic evaluation, longitudinal sections were made longitudinally by Maruto cutter(Maruto Co., Japan) and Maruto grinding machine(Maruto Co., Japan). Sections were examined and photographed by the polarizing light microscope(Olympus Optical Co., Japan) using crossed polars and with the enamel rod longitudinal axis oriented at $45^{\circ}$ to the extinction position. For scanning electron microscopic evaluation, the specimens were coated with a highly conducting layer of gold palladium in a model Hus-4 high-vacuum evaporator and examined in an ISI-100B scanning electron microcope operated at 20kV. The results of this study were as follows : 1. The mean depths of artificial carious lesions under a polarized light microscope were $Group\;A(5.08{\mu}m),\;Group\;B(47.82{\mu}m,\;Group\;C(8.42{\mu}m),\;Group\;D(7.20{\mu}m),\;Group\;E(85.41{\mu}m),\;Group\;F(60.38{\mu}m),\;Group\;G(60.13{\mu}m)$. 2. There were statistically significant differences in Group B compared with Group A, C, and D(p<0.05), and also, in Group I compared with Group F and Group G(p<0.05). 3. Light-and self-cured orthodontic sealants had the preventive effects of enamel demineralization. 4. Light-and self-cured orthodontic sealants had the progressive inhibitory effects of enamel demineralization. 5. The time progress of demineralizing agent had no influence on the samples of light-and self-cured orthodontic sealants under the scanning electron microscope. 6. There was no difference between the specimens of light-and self-cured orthodontic sealants both in the polarized light microscopic group and in the scanning electron microscopic group.

  • PDF

COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE (스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교)

  • Kim, Young-Kwang;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.516-526
    • /
    • 2004
  • Polymerization shrinkage of photoinitiation type composite resin cause several clinical problems. The purpose of this study was to evaluate the shrinkage strain stress, linear polymerization shrinkage, compressive strength and microhardness of recently developed composite resins. The composite resins were divided into four groups according to the contents of matrix and filler type. Group I : $Denfil^{TM}$(Vericom, Korea) with conventional matrix, Group II : $Charmfil^{(R)}$(Dentkist, Korea) with microfiller and nanofller mixture, Group III : $Filtek^{TM}$ Z250(3M-ESPE, USA) TEGDMA replaced by UDMA and Bis-EMA(6) in the matrix, and Group IV : $Filtek^{TM}$ Supreme(3M-ESPE, USA) using pure nanofiller. Preparation of acrylic molds were followed by filling and curing with light gun. Strain gauges were attached to each sample and the leads were connected to a strainmeter. With strainmeter shrinkage strain stress and linear polymerization shrinkage was measured for 10 minutes. The data detected at 1 minute and 10 minutes were analysed statistically with ONE-way ANOVA test. To evaluate the mechanical properties of tested materials, compressive hardness test and microhardness test were also rendered. The results can be summarized as follows : 1. Filling materials in acrylic molds showed initial temporary expansion in the early phase of polymerization. This was followed by contraction with the rapid increase in strain stress during the first 1 minute and gradually decreased during post-gel shrinkage phase. After 1 minute, there's no statistical differences of strain stress between groups. The highest strain stress was found in group IV and followed by group III, I, II at 10 minutes-measurement(p>.05). In regression analysis of strain stress, group III showed minimal inclination and followed by group II, I, IV during 1 minute. 2. In linear polymerization shrinkage test, the composite resins in every group showed initial increase of shrinkage velocity during the first 1 minute, followed by gradually decrease of shrinkage velocity. After 1 minute, group IV and group III showed statistical difference(p<.05). After 10 minutes, there were statistical differences between group IV and group I, III(p<.05) and between group II and group III(p<.05). In regression analysis of linear polymerization shrinkage, group II showed minimal inclination and followed by group IV, III, I during 1 minute. 3. In compressive strength test, group III showed the highest strength and followed by group II, IV, I. There were statistical differences between group III and group IV, I(p<.05). 4. In microhardness test, upper surfaces showed higher value than lower surfaces in every group(p<.05).

  • PDF

A THREE-DIMENSIONAL FEM COMPARISON STUDY ABOUT THE FORCE, DISPLACEMENT AND INITIAL STRESS DISTRIBUTION ON THE MAXILLARY FIRST MOLARS BY THE APPLICATION OF VAR10US ASYMMETRIC HEAD-GEAR (비대칭 헤드기어의 적용시 상악제 1 대구치에 나타나는힘과 변위 및 초기 응력분포에 관한 3차원 유한요소법적 연구)

  • Kim, Jong-Soo;Cha, Dyung-Suk;Ju, Jin-Won;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.25-38
    • /
    • 2001
  • The purpose of this study was to compare the force, the displacement and the stress distribution on the maxillary first molars altered by the application of various asymmetric head-gear. For this study, the finite element models of unilateral Cl II maxillary dental arch was made. Also, the finite element models of asymmetric face-bow was made. Three types of asymmetric face-bow were made : each of the right side 15mm, 25mm and 35mm shorter than the left side. We compared the forces, the displacement and the distribution of stress that were generated by application of various asymmetric head-gear, The results were as follows. 1. The total forces that both maxillary first molars received were similar in all groups. But the forces that mesially positioned tooth received were increased as the length of the outer-bow shortened, and the forces that normally positioned tooth received were decreased as the length of the outer-bow shortened. 2. In lateral force comparison, the buccal forces that normally positioned tooth received were increased as the length of the outer-bow shortened, and the buccal fortes that mesially positioned tooth received were decreased as the length of the outer-bow shortened. Though the net lateral force moved to the buccal side of normally positioned tooth as the length of the outer-bow shortened, both maxillary first molars received the buccal force. That showed 'Avchiai Expansion Effect' 3. The distal forces, the extrusion forces and the magnitudes of the crown distal tipping that mesially positioned tooth received were increased as the length of the outer-bow shortened, and the forces that normally positioned tooth received were decreased as the length of the outer-bow was shortened. 4. The magnitude of the distal-in rotation that normally positioned tooth received were increased as the length of the outer-bow was shortened. But, mesially positioned tooth show two different results. For the outer-bow 15mm shortened, mesially positioned tooth showed the distal-in rotation, hut for the outer-bow 25mm and 35mn shortened, mesially positioned tooth showed the distal-out rotation. Thus, the turning point exists between 15mm and 25mm. 5. This study of the initial stress distribution of the periodontal ligament at slightly inferior of the furcation area revealed that the compressive stress in the distobuccal root of the normally positioned tooth moved from the palatal side to the distal side and the buccal side successively as the length of the outer-bow shortened. 6. This study of the initial stress distribution of the periodontal ligament at slightly inferior of the furcation area revealed that the magnitudes of stress were altered but the total stress distributions were not altered in the mesiobuccal root and the palatal root of normally positioned tooth, and also three roots of mesially positioned tooth as the length of the outer-bow shortened.

  • PDF

A three-dimensional finite-element analysis of influence of splinting in mandibular posterior implants (스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구)

  • Baik, Sang-Hyun;Jang, Ik-Tae;Kim, Sung-Kyun;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.157-168
    • /
    • 2008
  • Statement of problem: Over the past two decades, implant supported fixed prosthesis have been widely used. However, there are few studies conducted systematically and intensively on the splinting effect of implant systems in mandible. Purpose: The purpose of this study was to investigate the changes in stress distributions in the mandibular implants with splinting or non-splinting crowns by performing finite element analysis. Materials and methods: Cortical and cancellous bone were modeled as homogeneous, transversely isotropic, linearly elastic. Perfect bonding was assumed at all interfaces. Implant models were classified as follows. Group 1: $Br{{\aa}}nemark$ length 8.5mm 13mm splinting type Group 2: $Br{{\aa}}nemark$ length 8.5mm 13mm Non-splinting type Group 3: ITI length 8.5mm 13mm splinting type Group 4: ITI length 8.5mm 13mm Non-splinting type An load of 100N was applied vertically and horizontally. Stress levels were calculated using von Mises stresses values. Results: 1. The stress distribution and maximum von Mises stress of two-length implants (8.5mm, 13mm) was similar. 2. The stress of vertical load concentrated on mesial side of implant while the stress of horizontal load was distributed on both side of implant. 3. Stress of internal connection type was spreading through abutment screw but the stress of external connection type was concentrated on cortical bone level. 4. Degree of stress reduction was higher in the external connection type than in the internal connection type.

Efficacy of Self-manipulation Technique in the Treatment of Patients with Anterior Disc Displacement without Reduction (비정복성 관절원판 전방변위 환자의 치료에 있어서 자가 수조작술의 효과에 대한 연구)

  • Kim, Ju-Sik;Lee, Chae-Hoon;Kim, Young-Ku
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.441-447
    • /
    • 2007
  • Internal derangement of the temporomandibular joint(TMJ) is defined as an abnormal relationship of the articular disc to the condyle. Mandibular manipulation is one of the conservative treatments to be considered first to manage the patients with anterior disc displacement without reduction. Mandibular manipulation is used to increase articular mobility and to restore the displaced disc into an anatomically normal position. While Farrar's technique has been popularly used, Minagi et al., Mongini and Suarez introduced the manipulation technique conducted by the patients themselves. But there is no study on the efficacy of self-manipulation technique, comparing with conventional one. The aim of this study was to investigate the efficacy of the conventional and self-manipulation technique, which was modified to complement the previously described technique by Minagi et al., in the treatment of patients with anterior disc displacement without reduction. TMD patients, who visited Department of Oral Medicine of Seoul National University Dental Hospital from December, 2002 to November, 2004 and were diagnosed as anterior disc displacement without reduction by TMJ magnetic resonance imaging (MRI) were enrolled. Conservative treatments including physical therapy, exercise, behavioral therapy, stabilization splint therapy, and manipulation therapy were done to every single patient until the symptomsimproved enough to discharge the patient. The charts were reviewed retrospectively according to the type of manipulation. In the results, patients whose maximum mouth opening was more than 40 mm was higher in the self-manipulation group(69.9%) than in the conventional manipulation group(42.9%). But difference between two groups was not significant. According to the fact that we decided to discharge the patients whentheir mouth opening increased to more than 40 mm and subjective symptoms such as pain and discomfort were improved as well, treatment period of discharged patients was significantly shorter in the self-manipulation group($29.2{\pm}12.3$ weeks) than in the conventional manipulation group ($61.0{\pm}38.0$ weeks) (p<0.01). In conclusion, in the treatment of TMD patients with anterior disc displacement without reduction, the self-manipulation technique which is performed by patients themselves is an effective treatment modality for increasing the range of mouth opening and shortening the total treatment period.