• Title/Summary/Keyword: 치과임상

Search Result 2,413, Processing Time 0.032 seconds

A study of lower facial change according to facial type when virtually vertical dimension increases (가상적 수직 교합 고경 증가 시 안모의 유형에 따른 하안모 변화에 관한 연구)

  • Kim, Nam-Woo;Lee, Gung-Chol;Moon, Cheol-Hyun;Bae, Jung-Yoon;Kim, Ji-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the effect of increased vertical dimension of occlusion on lower facial changes by facial type. Materials and methods: Lateral cephalograms from 261 patients were obtained and classified by sagittal (Class I, II, and III) and vertical (hypodivergent, normodivergent, and hyperdivergent) facial patterns. Retrusive displacement of soft tissue Pogonion and downward displacement of soft tissue Menton were measured in each group after 2 mm of vertical dimension of occlusion was increased at the lower central incisor using a virtual simulation program. The ratio of both displacements was calculated in all groups. The statistical analysis was done by 2-way ANOVA and Post hoc was done by Tukey test (5% level of significance). Results: Retrusive displacement of soft tissue Pogonion in Class III group was statistically different compared to Class I and II, and in vertical facial groups all 3 groups were significantly different (P<.05). Downward displacement of soft tissue Menton showed statistically significant difference between all sagittal groups and vertical groups (P<.05). The ratio of both displacements showed statistically significant difference in all sagittal groups and vertical groups (P<.05), and Class II hyperdivergent group had the highest value. Conclusion: Lower facial change was statically significant according to the facial type when vertical dimension of occlusion increased. Class II hyperdivergent facial type showed the highest ratio after increase in vertical dimension of occlusion.

Influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva (인공타액에 노출되었던 금속도재관의 재소성이 색조와 표면기포 형성에 미치는 영향에 관한 연구)

  • Park, Ji-Hyun;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.161-167
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva. Materials and methods: Thirty disk-shaped specimens were made in 10 mm diameter with 0.5 mm metal core thickness and 1 mm ceramic thickness. A spectroradiometer was used to determine the CIE Lab coordinates. The number and size of surface bubble were observed with a stereomicroscope. After the exposure to artificial saliva for 7 days, re-firing was performed at glazing temperature. After re-firing, the CIE Lab were calculated, and the number and size of surface bubble were observed again. The change in shade was expressed with ${\Delta}E$. Statistical analysis was done with paired t-test for the change in the number of surface bubble and student t-test for the change in the size of surface bubble (${\alpha$}=0.05). Results: Shade difference was calculated 2.14 ${\Delta}E$ units. The mean number of surface bubble was $1.33{\pm}1.49$ before re-firing, $3.27{\pm}2.90$ after re-firing. After re-firing, the number of surface bubble was significantly increased (P<.05). The mean size of surface bubble was $81.97{\pm}32.03\;{\mu}m$ before re-firing, $142.94{\pm}47.40\;{\mu}m$ after re-firing. After re-firing, the size of surface bubble was significantly increased (P<.05). Conclusion: Shade change after re-firing was perceptible (${\Delta}E$ < 2.0) and clinically acceptable (${\Delta}E$ < 3.7). The number and size of surface bubble was significantly increased after re-firing. Further investigation to decrease the surface bubble on the extra oral repair of metal-ceramic crown, will be needed in future study.

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

Marginal fit of three-unit zirconia anterior fixed dental prostheses fabricated using CAD/CAM and MAD/MAM system (CAD/CAM과 MAD/MAM 시스템으로 제작된 3-unit 지르코니아 고정성 국소의치의 변연 적합도에 관한 연구)

  • Song, Tae-Jin;Yeo, In-Sung;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.145-151
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the marginal fit of three-unit zirconia fixed dental prostheses (FDPs) fabricated using CAD/CAM and MAD/MAM system. Materials and methods: Dentiform maxillary central and lateral incisor were prepared for 3-unit FDP and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, fifteen 3-unit FDPs were fabricated. Metal-ceramic group was three-unit metal-ceramic FDPs, $Everest^{(R)}$ group was zirconia three-unit FDPs fabricated using the $Everest^{(R)}$ system (Kavo Dental GmbH, Biberach, Germany) and $Rainbow^{TM}$ group was zirconia three-unit FDPs fabricated using the $Rainbow^{TM}$ system (Dentium Co. Inc., Seoul, South Korea). They were cemented to resin dies with adhesive resin cement. After removing pontics, each retainers were separated and observed under measuring machine (Presize 440C) and analyzed through one-way ANOVA and Duncan test (${\alpha}$ = .05). Results: Mean values and standard deviations of marginal gap dimensions in each group for three-unit FDPs were $78.5{\pm}11.05\;{\mu}m$ for the metal-ceramic group, $59.30{\pm}11.63\;{\mu}m$ for the $Everest^{(R)}$ group and $70.34{\pm}13.98\;{\mu}m$ for the $Rainbow^{TM}$ group. Conclusion: 1. The $Everest^{(R)}$ group in comparison with metal-ceramic group showed better marginal fit, which had significant differences P<.05. 2. The mean marginal gap values between $Everest^{(R)}$ and $Rainbow^{TM}$ group did not showed significant differences (P>.05). 3. The mean marginal gap values between $Rainbow^{TM}$ group and metal-ceramic group did not showed significant differences (P>.05). 4. The mean marginal gaps of each group were within clinically acceptable range ($120\;{\mu}m$).

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.

Tensile bond strength of chairside reline resin to denture bases fabricated by subtractive and additive manufacturing (적층가공과 절삭가공으로 제작한 의치상과 직접 첨상용 레진 간의 인장결합강도 비교)

  • Kim, Hyo-Seong;Jung, Ji-Hye;Bae, Ji-Myung;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.177-184
    • /
    • 2020
  • Purpose: The purpose of this study was to compare and evaluate the tensile bond strength of chairside reline resin to denture base resin fabricated by different methods (subtractive manufacturing, additive manufacturing, and conventional heat-curing). Materials and methods: Denture base specimens were fabricated as cuboid specimens with a width of 25 mm × length 25 mm × height 3 mm by subtractive manufacturing (VITA VIONIC BASE), additive manufacturing (NextDent Base) and conventional heat-curing (Lucitone 199). After storing the specimens in distilled water at 37℃ for 30 days and drying them, they were relined with polyethyl methacrylate (PEMA) chairside reline resin (REBASE II Normal). The subtractive and additive manufacturing groups were set as the experimental group, and the heat-curing group was set as the control group. Ten specimens were prepared for each group. After storing all bound specimens in distilled water at 37℃ for 24 hours, the tensile bond strength between denture bases and chairside reline resin was measured by a universal testing machine at a crosshead speed of 10 mm/min. The fracture pattern of each specimen was analyzed and classified into adhesive failure, cohesive failure, and mixed failure. Tensile bond strength, according to the fabrication method, was analyzed by 1-way ANOVA and Bonferroni's method (α=.05). Results: Mean tensile bond strength of the heat-curing group (2.45 ± 0.39 MPa) and subtractive manufacturing group (2.33 ± 0.39 MPa) had no significant difference (P>.999). The additive manufacturing group showed significantly lower tensile bond strength (1.23 ± 0.36 MPa) compared to the other groups (P<.001). Most specimens of heat-curing and subtractive manufacturing groups had mixed failure, but mixed failure and adhesive failure showed the same frequency in additive manufacturing group. Conclusion: The mean tensile bond strength of the subtractive manufacturing group was not significantly different from the heat-curing group. The additive manufacturing group showed significantly lower mean tensile bond strength than the other two groups.

IN VITRO COMPARISON OF VARIOUS DIAGNOSTIC METHODS OF OCCLUSAL CAR10US LESIONS (교합면 우식병소의 다양한 진단법에 관한 비교연구)

  • Kim, Jae-Gon;Kim, Young-Jin;Kim, Young-Sin;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.613-619
    • /
    • 2001
  • The aims of this study were to compare the accuracy, sensitivity and specificity of cnventional visual examination, radiography and a new laser fluorescence method, KaVo Diagnodent, for the detection of occlusal caries lesions. One hundred sound human premolars and molars which had no restorations or interproximal cavities were tested by three methods. Tooth lesions depth was assessed at histologic examination using Caries detector dye The following results were obtained. 1. Diagnodent show 7.8 in sound tooth, 25.4 in initial caries, 30.5 in enamel caries, and 53.8 in dentin caries with average score 2. Spearman and Pearson relation coefficient was high between tooth-specimen test with dye and Diagnodent(0.736, 0.619), visual examination(0.664, 0.666), and was low between tooth-specimen test with dye and radiographic examination(P<0.01, total) 3. Accuracy of occlusal caries was highest on Diagnodent(65%) and lowest on radiographic examination(35%) 4. In initial caries, the sensitivity and specificity of Diagnodent method was the highest. In enamel caries, the sensitivity of visual examination was the highest and specificity of Diagnodent method was the highest. In dentinal caries, the sensitivity and specificity of Diagnodent method was the highest and sensitivity of visual examination was the lowest.

  • PDF

ERUPTION TIME AND SEQUENCE OF PERMANENT TEETH IN STUDENTS FROM E-ELEMENTARY SCHOOL (E-초등학교 어린이의 영구치 맹출시기 및 순서)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Lee, Jae-Ho;Kim, Seong-Oh;Son, Heung-Kyu;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.253-261
    • /
    • 2009
  • The purpose of this study was to present new data on the timing and sequence of permanent teeth emergence and to compare these findings with the results of earlier studies. The dental examinations had been performed to E-elementary school students, who visited the Yonsei University Dental Hospital between 1998 and 2005; 1,307 boys and 1,312 girls with the age ranging from 6 to 12 years old. The followings were concluded. 1. Eruption time of the maxillary permanent teeth is as follows. It was 6.81 years in male and 6.73 years in female for the central incisor, 7.78 years in male and 7.65 years in female for the lateral incisor, 10.48 years in male and 9.92 years in female for the canine, 9.76 years in male and 9.63 years in female for the first premolar, 10.66 years in male and 10.49 years in female for the second premolar, 6.39 years in male and 6.26 years in female for the first permanent molar, and 12.13 years in male and 12.03 years in female for the second permanent molar. 2. Eruption time of the mandibular permanent teeth is as follows. The central incisor could not be determined in this study, but it is assumed to erupt before the age of 6.08. In the mandible, eruption time was 6.78 years in male and 6.65 years in female for the lateral incisor, 9.76 years in male and 9.05 years in female for the canine, 9.82 years in male and 9.59 years in female for the first premolar, 10.67 years in male and 10.52 years in female for the second premolar, 6.22 years in male and 6.12 years in female for the first permanent molar, and 11.58 years in male and 11.14 years in female for the second permanent molar. 3. The eruption sequence is as follows. In the maxilla, the first permanent molar erupted first, followed by the central incisor, the lateral incisor, the first premolar, the canine, the second premolar, and the second permanent molar. In the mandible, the central incisor erupted first, followed by the first permanent molar, the lateral incisor, the canine, the first premolar, the second premolar, and the second permanent molar. 4. Tooth eruption occurred earlier in female compared to male by average of 0.19 year in the maxilla and 0.29 year in the mandible. 5. In both male and female, the hiatus (interval of rest) occurred between the emergence of lateral incisor and first premolar in the maxilla while it was observed between the lateral incisor and canine in the mandible. Male had a hiatus of 1.98 years in the maxilla and 2.90 years in the mandible, while the female's were 1.98 years and 2.40 years, respectively.

  • PDF

Microbial profile of asymptomatic and symptomatic teeth with primary endodontic infections by pyrosequencing (원발성 치근단 치주염을 갖는 감염근관에서 증상유무에 따른 세균분포의 pyrosequencing 분석)

  • Lim, Sang-Min;Lee, Tae-Kwon;Kim, Eun-Jeong;Park, Jun-Hong;Lee, Yoon;Bae, Kwang-Shik;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.498-505
    • /
    • 2011
  • Objectives: The purpose of this in vivo study was to investigate the microbial diversity in symptomatic and asymptomatic canals with primary endodontic infections by using GS FLX Titanium pyrosequencing. Materials and Methods: Sequencing was performed on 6 teeth (symptomatic, n = 3; asymptomatic, n = 3) with primary endodontic infections. Amplicons from hypervariable region of the small-subunit ribosomal RNA gene were generated by polymerized chain reaction (PCR), and sequenced by means of the GS FLX Titanium pyrosequencing. Results: On average, 10,639 and 45,455 16S rRNA sequences for asymptomatic and symptomatic teeth were obtained, respectively. Based on Ribosomal Database Project Classifier analysis, pyrosequencing identified the 141 bacterial genera in 13 phyla. The vast majority of sequences belonged to one of the seven phyla: Actinobacteria, Bacteroidetes, Firmicutes, Fusobacteria, Proteobacteria, Spirochetes, and Synergistetes. In genus level, Pyramidobacter, Streptococcus, and Leptotrichia constituted about 50% of microbial profile in asymptomatic teeth, whereas Neisseria, Propionibacterium, and Tessaracoccus were frequently found in symptomatic teeth (69%). Grouping the sequences in operational taxonomic units (3%) yielded 450 and 1,997 species level phylotypes in asymptomatic and symptomatic teeth, respectively. The total bacteria counts were significantly higher in symptomatic teeth than that of asymptomatic teeth (p < 0.05). Conclusions: GS FLX Titanium pyrosequencing could reveal a previously unidentified high bacterial diversity in primary endodontic infections.

Cytotoxic Effects of Prevotella nigrescens on Cultured Cells (Prevotella nigrescens가 배양된 세포에 미치는 영향)

  • Han, Jin-Soon;Kim, Eun-Sook;Lee, Su-Jong;You, Yong-Ouk;Han, Kyung-Soo;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.183-195
    • /
    • 2002
  • 흑색 색소를 형성하는 그람음성 혐기성 세균은 급성 임상 증상을 가진 환자의 근관에서 자주 발견되는 세균으로서 세균 및 세균의 성분과 산물이 치근단 병소의 생성과 밀접하게 연관된 것으로 알려져 있다. 본 연구는 흑색 색소를 형성하는 그람음성 혐기성 세균 중 가장 발현율이 높은 Prevotella nigrescens가 배양된 세포에 미치는 세포 독성을 연구하고자 하였다. 두 가지 세포주 및 사람의 치은섬유모세포를 일차배양하여 사용하였으며, 세포주에 따른 독성 발현에 차이가 있는지를 비교하였다. P. nigrescens ATCC 33563 표준 균주 및 임상 균주로는 환자의 감염된 근관으로부터 165 rRNA primer를 사용한 중합효소 연쇄반응으로 P. nigrescens 6 균주를 동정하여 사용하였다. 세균배양액, 세균의 초음파 추출단백질 및 lipopolysaccharide (LPS)를 MC3T3-El 조골세포, NIH3T3 섬유모세포 및 치은섬유모세포에 첨가한 후 MTT분석법으로 세포의 활성을 측정하였으며, 세포의 형태학적 변화를 도립현미경으로 관찰하였다. 세균배양액을 100$\mu\textrm{l}$ 첨가한 경우는 세가지 세포주 모두에서 통계적으로 유의하게 세포의 활성을 억제하였다. 세균의 초음파 추출단백질 12.5$\mu\textrm{g}$/ml 와 25$\mu\textrm{g}$/ml 는 NIH3T3세포에 통계적으로 유의한 세포독성을 보였다. 세 가지 세포주에 대한 LPS의 세포 독성 효과는 첨가된 LPS의 농도 및 균주에 따라 다양하게 나타났다. 심하게 손상된 세포는 세포의 단일층이 수축되고 세포가 응집되었으며 세포가 배양용기의 바닥에서 떨어지는 양상이 도립 현미경하에서 관찰되었다. 본 연구의 결과 P. nigrescens가 숙주 반응을 조절하여 치수 및 치근단 병소의 유발 및 악화에 기여하는 세균으로 작용할 수 있음을 시사한다. 조직과 함께 제거하고 포르말린에서 48시간 고정시킨 후 파라핀에 포매한 다음에 micro-tome을 사용하여 6$\mu\textrm{m}$로 serial section을 시행하였다. 정중선 부위의 시편에 Hematoxylin-Eosin staining을 시행한 후 Olsson, Orstavik 그리고 Mjor 등의 방법에 따라 조직학적 변화를 관찰한 후 slight(1), moderate(2), severe inflammation(3)의 단계로 분류하였다. 얻어진 결과를 통계처리 프로그램인 Jandel사의 Sigmastat을 이용하여 Kruskal Wallis Test로 통계처리를 하였다. 결과 : (Table omitted) 결론 : 1) Pulp Canal Sealer를 제외한 모든 군에서 시간이 지남에 따라 유의성 있게 염증이 감소되는 양상을 보였다(p<0.05). 2) Pulp Canal Sealer는 1주, 2주, 12주에서 강한 염증반응을 보였다. 3) AH 26과 AH Plus에서는 1주, 2주에서 강한 염증반응을 보였으나 12주에서는 염증반응이 감소하였다. 4) 새로 개발된 봉함제 Adseal-1,2는 1주, 2주에서는 가장 약한 염증반응을 보이나 4주, 12주 후에는 AH Plus와 비슷한 수준의 염증 반응을 보였다. 5) Pulp Canal Sealer를 제외한 모든 군에서 인정할 만한 생체친화성을 보였다. 6) Adseal-2가 Adseal-1에 비하여 전반적으로 낮은 염증반응을 보였다. 7) 각 군간 결과의 차이에 통계적 유의성은 없었다(p>0.05).mmunity. Then, a hierarchical language is to defeat its own purpose.중 행정부가 북한에 대해 실시한 포용정책이 어떠한 성과를 거두고 어떠한 문제점을 간과하고 있는가에 대해 논의하고, 대북 정책의 새로운 지평을 논의하는 것을 목적으로 하고 있다. 1) 포용 정책은 세계의