• Title/Summary/Keyword: 치과용 모형

Search Result 93, Processing Time 0.021 seconds

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

Evaluation of Dimensional Stability of Digital Dental Model Fabricated by Impression Scanning Method (인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적 안정성 평가)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.14 no.1
    • /
    • pp.15-21
    • /
    • 2014
  • The purpose of this study in vitro investigation was to evaluate the dimensional stability of dental digital models made by impression scanning method. Twenty working models were produced. Twenty impressions were made from study models. The dimensional stability of models of two groups (stone and digital models) was examined using six landmark distances. Stone models were measured through digital vernier calipers. Digital models were measured by the computer program. Statistical analyses were performed with Wilcoxon rank sum test (${\alpha}=0.05$). The mean of six landmark distances were significantly larger in the stone models than in the digital models (p<0.05) but digital models showed clinically acceptable accuracy.

Evaluations of the Accuracy and Reliability of Measurements Made on White Light Scanner-based Dental Digital Models (백색광 스캐너로 채득된 치과용 디지털모형의 정확도와 신뢰도 평가)

  • Kim, Ki-Baek;Kim, Jae-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.357-364
    • /
    • 2012
  • Dental scanner-based dental digital models have been developed that have the potential to replace conventional stone model. The aim of this study was examine the accuracy and reliability of measurements made on digital models. A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the white light scanner(Identica, korea). One examiner individually measured 6 parameters on the conventional model and the digital models on two occasions. The student's t-test for paired samples and intra-class correlation coefficient(ICC) were used for statistical analysis. At the intra-examiner reliability of measurement, ICC at the stone and digital models were 0.75 and 0.87. The mean difference between measurements made directly on the stone models and those made on the digital models was 0.11-0.23mm, and was statistically significant(P<0.05). These in vitro studies show that accuracy of the digital model is similar to that of the stone model. These results will have to be confirmed in further clinical studies.

Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication (총의치 제작을 위한 무치악 디지털 모형의 정확도 평가)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.393-398
    • /
    • 2015
  • One of the most critical causes in determining the clinical outcomes of dental prostheses is the validity of models. However, studies that evaluated validity of digital models are few. The objectives of this study were to evaluate validity of edentulous digital models for full denture fabrication. Twenty stone models (edentulous model) were manufactured and scanned by dental blue light emitting diode scanner. Twenty digital models were manufactured. Six linear distances (inter-canine distance, inter-molar distance, two dental arch lengths (right, left), two diagonal of dental arch lengths (right, left) were measured for validity evaluation. The measurements of distances of stone models were used by digital vernier caliper and digital models were used by computer program. The mean${\pm}$deviations values of six distances were calculated. The means were compared by the Mann Whitney U test (${\alpha}=0.05$). All statistical analysis were performed using IBM SPSS Statistics ver. 20.0. Although digital models were smaller than stone models in six distances, there were no significant differences (p>0.05) and non exceeded the clinical acceptable range. The edentulous digital models for full denture fabrication can be considered clinically acceptable.

치과용 인상재의 비교 응용

  • Kim, Cheol-Wi
    • The Journal of the Korean dental association
    • /
    • v.24 no.3 s.202
    • /
    • pp.199-203
    • /
    • 1986
  • 치과용 인상재는 구강내에서 치아나 주위조직을 정확히 인기하여야 하며 조작이 간편하고 유동성이 충분하며 경화시간이 적당하고 값도 저렴해야 한다. 또 구강내에서 제거할 때 영구변형이나 파절되지 않는 충분한 강도와 크기의 정확성도 있어야 하며 자극이나 독성이 없고 인체에 안정성이 있고 모형재와 친화성이 있으며 보관중에도 변질해서는 안된다. 그러나 인상재는 서로 상이한 특성이 있고 장단점이 각각 다르므로 모든 조건에 일치하는 인상재는 거의 없다. 따라서 여러 인상재중에서 가장 적합한 인상재를 선택하는 것이 중요한 과정이다. 즉 인상재의 특성과 응용을 알고 선택할땐 보다 정밀한 모형을 얻을 수 있다. 기록에 의하면 18~19세기경에 최초로 인상용 왁스를 사용한 이래 19세기 중엽에 인상용 석고, 1925년에 agar, 1930년 ZOE, 1945년 앨지네이트, 1957년 실리콘, 1967년 polyether 및 1975년 부가중합형 실리콘이 사용되었으며 인상재가 유연성과 탄성이 있는가 경고하며 비탄성인가 또는 온도변화와 화학반응으로 경화되는 가에 따라서 ZOE paste, 인상용 석고, 인상용 왁스, 인상용 콤파운드, 수성콜로이드(agar, 앨지네이트), polysulfide, 실리콘(축중합형, 부가중합형) 및 polyether 인상재등 10여종으로 분류된다.

  • PDF

Evaluation of validity of three dimensional dental digital model made from blue LED dental scanner (Blue LED 방식의 스캐너로 제작된 치과용 3차원 디지털 모형의 정확도 평가)

  • Kim, Jae-Hong;Jung, Jae-Kwan;Kim, Ki-Baek
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3007-3013
    • /
    • 2014
  • The objectives of this study was to evaluate the validity of 3D digital models made from blue LED dental scanner. Twenty same cases of stone models and 3d digital models were manufactured for this study. Intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) were measured for evaluation of validity. The nonparametric Wilcoxon rank sum test was used for statistical analysis (${\alpha}$=0.05). Although stone models showed larger than digital models in all measured distances(p<0.05), none exceeded the clinically acceptable range.

Accuracy of conventional and digital mounting of dental models: A literature review (치과용 모형의 모형 부착 과정에서 발생하는 오차에 대한 문헌 고찰)

  • Kim, Cheolmin;Ji, Woon;Chang, Jaeseung;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.146-152
    • /
    • 2021
  • Accurate transfer of the maxillo-mandibular relationship to an articulator (i.e., mounting) is critical in prosthetic treatment procedures. In the current study, a PubMed search was performed to review the influencing factors for the maxillo-mandibular relationship's accuracy. The search included digital mounting as well as conventional gypsum cast mounting. The results showed that a greater amount of displacement was introduced during positioning the maxillary and mandibular models to interocclusal records rather than the dimensional change of registration material. Most intraoral scanners resulted in an accurate reproduction of the maxillo-mandibular relationship for posterior quadrant scanning; however, the accuracy was declined as the scan area increased to a complete arch scan. The digital mounting accuracy was also influenced by the image processing algorithms and software versions, especially for complete arch scans.