• Title/Summary/Keyword: 층간 변위

Search Result 173, Processing Time 0.023 seconds

Dynamic Response of Seismically Isolated High-Story Buildings according to Earthquake Records (지진기록 사용에 따른 고층 면진건물의 동적 응답)

  • Lee, Hyun-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.643-651
    • /
    • 2008
  • The purpose of this study is to evaluate seismic capacity of seismically isolated building according to the earthquake motion record selection method. To analyze the seismic behavior, 20-story building is designed, which has base isolation system. The using earthquake motion record were selected by two categories. The one is a proposed earthquake record according to soil type and response spectrum shape, and the other is a well known earthquake events such as El Centro (1940). The time history analysis results of base isolation buildings be induced difference results according to each ground motion records. Therefore detailed guidelines for the ground motion records selection method must be prepared. And the response of isolation story displacement and shear force show good seismic performance in consideration of the proposed earthquake records.

Seismic Performance Evaluation of Masonry-Infilled Frame Structures using Equivalent Strut Models (등가 스트럿 모델을 이용한 조적조 채움벽 골조의 내진성능평가)

  • Park, Ji-Hun;Jeon, Seong-Ha;Kang, Kyung-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.47-59
    • /
    • 2012
  • The seismic performance of masonry-infilled frame structures, typical in school buildings, is evaluated through equivalent strut models. A bare frame model, concentric strut models and eccentric strut models with various material characteristics available in the literature are analyzed. Displacements and damage states at the performance points obtained by the capacity spectrum method show great differences among the models. Infill walls act positively in concentric strut models and negatively in eccentric strut models at the performance points for a given seismic demand. In addition, the behavior at the ultimate displacements shows considerably different strengths, inter-story drifts, and numbers and locations of damaged members among various modeling methods and material strengths.

Inelastic Dynamic Demands of a RC Special Moment Frame Building (철근 콘크리트 특수 모멘트 골조 건물의 비탄성 동적 요구값)

  • Kim, Tae-Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.11-19
    • /
    • 2005
  • Seismic design of a building is usually performed by using the linear static procedure. However, the actual behavior of the building subjected to earthquake is inelastic and dynamic in nature. Therefore, inelastic dynamic analysis is required to evaluate the safety of the structure designed by the current design codes. For the validation, a RC special moment resisting frame building was chosen and designed by IBC 2003 representing new codes. Maximum plastic rotation and dissipated energy of some selected members were calculated for examining if the inelastic behavior of the building follows the intention of the code, and drift demand were calculated as well for checking if the building well satisfies the design drift limit. In addition, the effect of including internal moment resisting frames (non lateral resisting system) on analyses results was investigated. As a result of this study, the building designed by IBC 2003 showed the inelastic behavior intended in the code and satisfied the design drift limit. Furthermore, the internal moment resisting frames should be included in the analytical model as they affect the results of seismic analyses significantly.

Performance Evaluation of TMD and TLCD for Earthquake-Induced Response Control (TMD와 TLCD의 지진응답에 대한 제어성능 평가 연구)

  • 김홍진;김형섭;민경원;오정근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.85-91
    • /
    • 2003
  • TLCD is a good alternative to TMD for control of structures because of its cost efficiency, ease of installation, little maintenance requirement, potential for multiple usage, and ease of re-tuning. In this study, the control performances of TMD and TLCD are evaluated and compared for seismically excited structures. Results show that TLCD is more effective than TMD for interstory drift control while TLCD is as effective as TMD for acceleration control. In special. it is shown that interstory drifts are maximally controlled in lower floors and accelerations are reduced most in upper floors. This indicates that TLCD is an effective controller for earthquake-induced structures in terms of structural safety as well as serviceability.

Prediction of Member Plastic Rotation Demands for Earthquake Design of Moment Frames (모멘트골조의 내진설계를 위한 부재 소성변형 요구량 예측)

  • Eom, Tae-Sung;Park, Hong-Gun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.51-60
    • /
    • 2009
  • To secure the structural safety of structures and members against earthquakes, the plastic deformation capacity demand of members should be accurately predicted. In the present study, a method for the evaluation of the plastic deformations of members for moment frames was developed. To facilitate the practical use of the proposed method in equivalent seismic design, the plastic deformations of members were evaluated based on the results of elastic analysis, without using nonlinear analysis. The plastic deformation demands of members were formulated as functions of story drift demand, redistributed moment and member stiffness. Story drift demand and moment redistribution were directly determined from elastic analysis. The proposed method was applied to an 8 story-2 bay moment frame, and the predicted plastic deformations were verified using nonlinear analysis. The results showed that the proposed method could be used to accurately predict the member plastic rotations with simple calculations. The proposed method can be applied both to the earthquake design of new structures and to the performance evaluation of existing structures.

Seismic Performance of HyFo Beam with High Depth-to-SRC Column Connections (춤이 큰 하이브리드 합성보와 SRC기둥 접합부의 내진성능에 관한 연구)

  • Kim, Sung Bae;Jeon, Yong Han;Cho, Seong Hyun;Choi, Young Han;Kim, Sang Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.2
    • /
    • pp.135-145
    • /
    • 2017
  • This study is a secondary study that is a cyclic seismic test of High depth hybrid composite beam and column connection after the primary bending strength test of a high depth Hybrid composite beam. Total of 3 seismic test specimens were prepared to cyclic test. The bracket and beam web spliced by high strength bolt and the bracket and beam upper flange was spliced by welding. Test results showed that the seismic strength was higher than the plastic moment($M_p$) in the positive negative moment section, the requirement of composite intermediate moment frame wes satisfied. Therefore, the requirement of intermediate moment frame can be secured by applying the details of connection of this study results.

Inelastic Seismic Response of Asymmetric-Plan Self-Centering Energy Dissipative Braced Frames (비정형 셀프센터링 가새골조의 비탄성 지진응답)

  • Kim, Jin-Koo;Christopoulos, C.;Choi, Hyun-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.35-44
    • /
    • 2008
  • A self-centering energy-dissipative(SCED) bracing system has recently been developed as a new seismic force resistant bracing system. The advantage of the SCED brace system is that, unlike other comparable advanced bracing systems that dissipate energy such as the buckling restrained brace(BRB) system, it has a self-centering capability that reduces or eliminates residual building deformations after major seismic events. In order to investigate the effects of torsion on the SCED brace and BRB systems, nonlinear time history analyses were used to compare the responses of 3D model structures with three different amounts of frame eccentricity. The results of the analysis showed that the interstory drifts of SCED braced frames are more uniform than those of BRB frames, without regard to irregularity. The residual drift and residual rotation responses tended to decrease as irregularity increased. For medium-rise structures, the drift concentration factors(DCFs) for SCED systems were lower than those for BRB frames. This means that SCED-braced frames deform in a more uniform manner with respect to building height. The effect of the torsional irregularity on the magnitude of the DCFs was small.

Seismic Performance Evaluation of Nonseismic Neighborhood Living Facilities Considering Deterioration (비내진 근린생활시설의 노후도를 고려한 내진성능평가)

  • Lee, Young Cheon;Jeoung, Chae Myeoung;Lee, Eun Jin;Kim, Myung Hoon;Choi, Ki Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • In this study, seismic performance was evaluated considering the deterioration level for the low-rise and moderate buildings with non-seismic details which are most common in Korea. Evaluation results showed that the deterioration condition is relatively good even after 24 years of construction but the seismic performance did not satisfy the protection index in the first and second evaluation. In case of the third evaluation, the goal performance was satisfied based on the interstory drift ratio but reinforcement is found to be necessary. Seismic performance was evaluated after the target buildings were reinforced in the walls, bracing, and damper. Results showed the interstory drift ratio drastically reduced regardless of reinforcement methods and satisfied the level of immediate occupancy. In case of wall reinforcement, however, base shear increased more than double which requires review on the existing foundation.

Evaluation of Member Plastic Deformation Demands for Dual Systems with Special Moment Frames (특수모멘트골조를 가진 이중골조시스템을 위한 부재소성변형 평가)

  • Eom, Tae-Sung;Kim, Jae-Yo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.41-51
    • /
    • 2010
  • For safe seismic evaluation and design, it is necessary to predict the plastic deformation demands of members. In the present study, a quick and reasonable method for the evaluation of member plastic deformations of dual systems was developed on the basis of results of elastic analysis, without using nonlinear analysis. Plastic deformations of beams, columns, and walls are functions of member stiffness, story drift ratio, and moment redistribution determined from elastic analysis. For dual systems with rigid connections between walls and beams, an increase in the plastic deformations of beams due to the rocking effect was considered. The proposed method was applied to 8-story dual systems and the predicted plastic deformations were compared with the results of nonlinear analysis. The results showed that the proposed method accurately predicted the member plastic deformations with simple calculations, but that for the accurate evaluation of member plastic deformations, the inelastic story drift ratio must also be predicted with accuracy. The proposed method can be applied to both the performance-based seismic design of new structures and the seismic evaluation of existing structures.

A Study on Earthquke Damage Estimation of Non Precede Designed Reinforced Concrete Apartment in Korea (국내 비내진 설계 철근콘크리트 아파트에 대한 지진피해 예측 연구)

  • Kwon, Ki-Hyuk;Ko, Yong-Bum
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.95-105
    • /
    • 2005
  • Korea is located away from plate boundaries which are not safe from earthquakes. However, having witnessed the large-scale earthquake in the Tangshan region in 1976 deemed as a safe plate, it should not be assured that Korea is absolutely safe from earthquakes. In addition, many seismologists have claimed that there indeed is a high possibility of earthquakes above mid scale that would occur in Korea. Because it is impossible to prevent earthquake, studies on seismic design and earthquake disaster control system are widely being conducted. However, studies on early response to earthquakes or recovery process are still very limited, and only a few studies for establishing earthquake damage evaluation system are being conducted. Thus, this study aimed to present essential data for establishing earthquake damage evaluation system that takes into account the real situation of structures in Korea. In this study, a nonseimically reinforced concrete apartment structure in Gangnamgu was selected as an standard type of such structures and its earthquake damage was estimated. The result of damage evaluation based on the derivation of vulnerability function and realtive story displacement was compared to that abtained using HAZUS Program Vulnerability Function.