• Title/Summary/Keyword: 측정 표준안

Search Result 173, Processing Time 0.038 seconds

Study on the channel of bipolar plate for PEM fuel cell (고분자 전해질 연료전지용 바이폴라 플레이트의 유로 연구)

  • Ahn Bum Jong;Ko Jae-Churl;Jo Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.15-27
    • /
    • 2004
  • The purpose of this paper is to improve the performance of Polymer electrolyte fuel cell(PEMFC) by studying the channel dimension of bipolar plates using commercial CFD program 'Fluent'. Simulations are done ranging from 0.5 to 3.0mm for different size in order to find the channel size which shoves the highst hydrogen consumption. The results showed that the smaller channel width, land width, channel depth, the higher hydrogen consumption in anode. When channel width is increased, the pressure drop in channel is decreased because total channel length Is decreased, and when land width is increased, the net hydrogen consumption is decreased because hydrogen is diffused under the land width. It is also found that the influence of hydrogen consumption is larger at different channel width than it at different land width. The change of hydrogen consumption with different channel depth isn't as large as it with different channel width, but channel depth has to be small as can as it does because it has influence on the volume of bipolar plates. however the hydrogen utilization among the channel sizes more than 1.0mm which can be machined in reality is the most at channel width 1.0, land width 1.0, channel depth 0.5mm and considered as optimum channel size. The fuel cell combined with 2cm${\times}$2cm diagonal or serpentine type flow field and MEA(Membrane Electrode Assembly) is tested using 100W PEMFC test station to confirm that the channel size studied in simulation. The results showed that diagonal and serpentine flow field have similarly high OCV and current density of diagonal (low field is higher($2-40mA/m^2$) than that of serpentine flow field under 0.6 voltage, but the current density of serpentine type has higher performance($5-10mA/m^2$) than that of diagonal flow field under 0.7-0.8 voltage.

  • PDF

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Estimation of Genetic Parameters for Growth-related Traits of Two Korean Abalone Subspecies, Haliotis discus hannai and H. discus discus, by using Multiple Traits of Animal Model in Early Growth Period (다형질 Animal Model에 의한 한국산 전복 2 아종의 초기 치패의 성장관련 형질에 대한 유전모수 추정)

  • Choe, Mi-Kyung;Han, Seock-Jung;Yang, Sang-Geun;Won, Seung-Hwan;Park, Choul-Ji;Yeo, In-Kyu
    • The Korean Journal of Malacology
    • /
    • v.23 no.2
    • /
    • pp.217-225
    • /
    • 2007
  • This study was conducted to estimate the general genetic parameters, heritabilities, and genetic and phenotypic correlations on growth-related traits by studying multiple trait animal model in two Korean abalone species, Haliotis discus hannai and H. discus discus. The data was collected from the records of 3,795 individuals produced from 54 sires and 74 dams in Haliotis discus hannai and 399 individuals produced from 7 sires and 7 dams in Haliotis discus discus. The data was evaluated by the Genetics and Breeding Research Center, National Fisheries Research & Development Institute (NFRDI). Genetic parameters were estimated for two abalone species raised in Bukjeju branch, NFRDI, from May 20 to November 1, 2004. The heritability estimates for growth traits of shell length, shell width and body weight obtained from restricted maximum likelihood (REML) were ranging from 0.73 to 0.78 in Haliotis discus hannai, and from 0.87 to 0.89 in H. discus discus. The heritabilities for shell shape and condition factor were ranging from 0.17 to 0.20 in Haliotis discus hannai, and from 0.01 to 0.45 in H. discus discus. Genetic and phenotypic correlations were over than 0.96 between shell parameters and weight in both of abalone subspecies, indicating that breeding for weight gains could successfully be achieved by selecting for shell length.

  • PDF

Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy (3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석)

  • Seong, Yeol-Hun;Rhim, Jae-Dong;Lee, Jae-Hyun;Cho, Sung-Bong;Woo, Dong-Chul;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.256-262
    • /
    • 2008
  • To evaluate the metabolic changes in normal adult brains due to alterations SENSE and NEX (number of excitation) by multi voxel MR Spectroscopy at 3.0 Tesla. The study group was composed of normal volunteers (5 men and 8 women) with a mean ($\pm$ standard deviation) age of 41 (${\pm}11.65$). Their ages ranged from 28 to 61 years. MR Spectroscopy was performed with a 3.0T Achieva Release Version 2.0 (Philips Medical System-Netherlands). The 8 channel head coil was employed for MRS acquisition. The 13 volunteers underwent multi voxel spectroscopy (MVS) and single voxel spectroscopy (SVS) on the thalamus area with normally gray matter. Spectral parameters were as follows: 15 mm of thickness; 230 mm of FOV (field of view); 2000 msecs of repetition time (TR); 288 msecs of echo time (TE); $110{\times}110$ mm of VOI (view of interest); $15{\times}15{\times}15$ mm of voxel size. Multi voxel spectral parameters were made using specially in alteration of SENSE factor (1~3) and 1~2 of NEX. All MRS data were processed by the jMRUI 3.0 Version. There was no significant difference in NAA/Cr and Cho/Cr ratio between MVS and SVS likewise the previous results by Ross and coworkers in 1994. In addition, despite the alterations of SENSE factor and NEX in MVS, the metabolite ratios were not changed (F-value : 1.37, D.F : 3, P-value : 0.262). However, line-width of NAA peak in MVS was 3 times bigger than that in SVS. In the present study, we demonstrated that the alterations of SENSE factor and NEX were not critically affective to the result of metabolic ratios in the normal brain tissue.

  • PDF

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

An Evaluation of the Private Security Industry Regulations in Queensland : A Critique (호주 민간시큐리티 산업의 비판적 고찰 : 퀸즐랜드주를 중심으로)

  • Kim, Dae-Woon;Jung, Yook-Sang
    • Korean Security Journal
    • /
    • no.44
    • /
    • pp.7-35
    • /
    • 2015
  • The objective of this article is to inform and document the contemporary development of the private security industry in Queensland Australia, a premier holiday destination that provide entertainment for the larger region. The purpose of this review is to examine the comtemporary development of mandated licensing regimes regulating the industry, and the necessary reform agenda. The overall aim is threefold: first, to chart the main outcomes of the two-wave of reforms since the mid-'90s; second, to examine the effectiveness of changes in modes of regulation; and third, to identify the criteria that can be considered a best practice based on Button(2012) and Prenzler and Sarre's(2014) criteria. The survey of the Queensland regulatory regime has demonstrated that, despite the federal-guided reforms, there remain key areas where further initiatives remain pending, markedly case-by-case utilisation of more proactive strategies such as on-site alcohol/drug testing, psychological evaluations, and checks on close associates; lack of binding training arrangement for technical services providers; and targeted auditing of licensed premises and the vicinity of venues by the Office of Fair Trading, a licensing authority. The study has highlighted the need for more determined responses and active engagements in these priority areas. This study of the development of the licensing regimes in Queensland Australia provides useful insights for other jurisdictions including South Korea on how to better manage licensing system, including the measures required to assure an adequate level of professional competence in the industry. It should be noted that implementing a consistency in delivery mode and assessment in training was the strategic imperative for the Australian authority to intervene in the industry as part of stimulating police-private partnerships. Of particular note, competency elements have conventionally been given a low priority in South Korea, as exemplified through the lack of government-sponsored certificate; this is an area South Korean policymakers must assume an active role in implementing accredited scheme, via consulting transnational templates, including Australian qualifications framework.

  • PDF

Estimation of Genetic Parameters for Growth-Related Traits in 1-Year Old of Two Korean Abalone Subspecies, Haliotis discus hannai and H. discus discus, by Using Multiple Traits of Animal Model (다형질 Animal Model에 의한 12개월령 한국산 전북 2 아종의 성장관련형질에 대한 유전모수 추정)

  • Choe, Mi-Kyung;Han, Seock-Jung;Yang, Sang-Geun;Won, Seung-Hwan;Park, Choul-Ji;Yeo, In-Kyu
    • The Korean Journal of Malacology
    • /
    • v.24 no.2
    • /
    • pp.121-130
    • /
    • 2008
  • In other aquaculture species, large improvements in growth have been achieved through selective breeding. Ezo abalone(Haliotis discus hannai) and disk abalone(H. discus discus) are major aquatic animals cultured in Asia, but selective breeding for the promotion of growth with these abalones has not been actively pursued. Recently significant efforts are being made to promote production of these species through selective breeding in Korea. The aims of this work were to estimate the general genetic parameters, heritabilities, and genetic and phenotypic correlations on growth-related traits at 1-year old in two Korean abalone subspecies, H. discus hannai and H. discus discus, by using multiple trait animal model. The data were collected from the records of 1,504 individuals produced from 22 sires and 26 dams in H. discus hannai and 297 individuals produced from 5 sires and 6 dams in H. discus discus, which evaluated by the Genetics and Breeding Research Center, National Fisheries Research & Development Institute(NFRDI). Genetic parameters were estimated for these abalone subspecies raised in Bukjeju branch, NFRDI, from May 20, 2004 to May 16, 2005, respectively. The heritability estimates obtained from restricted maximum likelihood(REML) were higher than expected, ranging from 0.40 to 0.43 for growth traits shell length, shell width and body weight in H. discus hannai and from 0.26 to 0.51 in H. discus discus, respectively. The heritabilities for shell shape and condition factor were lower than others of growth traits such as ranging from 0.09 to 0.19 in H. discus hannai and from 0.10 to 0.23 in H. discus discus, respectively. Genetic and phenotypic were > 0.93 between shell parameters and weight in two abalone species, respectively, indicating that breeding for weight gains could be successfully achieved by selecting for shell length.

  • PDF

Influence of the Levee-burning on the Fauna of Insect Pests and Their Natural Enemies (쥐불놀이 (논둑태우기)가 해충 및 천적상에 미치는 영향)

  • 김홍선;이영인;이해빈
    • Korean journal of applied entomology
    • /
    • v.29 no.3
    • /
    • pp.209-215
    • /
    • 1990
  • Some preliminary studies were conducted to find out whether the levee-burning could justifiable for the suppression of insect pests, particularly the smaller brown planthopper (Laodelphax striatellus F.). Density surveys on pests and their enemies (mostly spiders) were carried out upto the mid May at an experimental paddy field located in Suwon after of it's levee $(72\times1m)$ was burned on Feb. 20, 1987. Results were discussed in relation to density recovering of both pests and their possible enemies (spiders) and summarized as below. Not a single individual of any pest or enemy was found from the levee upto sometime after the levee-burning. Grasses started to grow more vigorously in burned ares than in unburned upto about 60 days after the burning. And densities of both pest and enemies grew higher in burned areas than in unburned from about 75 days after the burning (in Early may). It is suspected that all individuals of pests and enemies fond from the burned areas could have immigrated from the surrounding areas. If levee-burning was carried out in much wider areas, much longer time would be needed to recover the density of both pests and enemies to the center region of the burning. Wingless spiders would require even longer time than winged pest species to re-establish in the center region of the widely burned field. Pirata subpiraticus, the most abundant spider species in Korean paddy fields, starts to move about and searches for food at above $9^{\circ}C$ which is somewhat lower than the critical temperature for the pest species. Thus P. subpiraticus would require more food than other pest species early in the spring, and therefore, it would have lower probability to survive than pest species particularly in burned areas. Experiments for pest suppression with levee-burning would better be carried on in much wider areas, and its justification seems to be discussed after man other disciplines related to both pests and their natural enemies were throughly studied together with their density surveys. However, according to the present point of vie, the opinion that levee-burning is helpful for controlling pests which over winter on levee areas could not be justifiable.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Introduction of GOCI-II Atmospheric Correction Algorithm and Its Initial Validations (GOCI-II 대기보정 알고리즘의 소개 및 초기단계 검증 결과)

  • Ahn, Jae-Hyun;Kim, Kwang-Seok;Lee, Eun-Kyung;Bae, Su-Jung;Lee, Kyeong-Sang;Moon, Jeong-Eon;Han, Tai-Hyun;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1259-1268
    • /
    • 2021
  • The 2nd Geostationary Ocean Color Imager (GOCI-II) is the successor to the Geostationary Ocean Color Imager (GOCI), which employs one near-ultraviolet wavelength (380 nm) and eight visible wavelengths(412, 443, 490, 510, 555, 620, 660, 680 nm) and three near-infrared wavelengths(709, 745, 865 nm) to observe the marine environment in Northeast Asia, including the Korean Peninsula. However, the multispectral radiance image observed at satellite altitude includes both the water-leaving radiance and the atmospheric path radiance. Therefore, the atmospheric correction process to estimate the water-leaving radiance without the path radiance is essential for analyzing the ocean environment. This manuscript describes the GOCI-II standard atmospheric correction algorithm and its initial phase validation. The GOCI-II atmospheric correction method is theoretically based on the previous GOCI atmospheric correction, then partially improved for turbid water with the GOCI-II's two additional bands, i.e., 620 and 709 nm. The match-up showed an acceptable result, with the mean absolute percentage errors are fall within 5% in blue bands. It is supposed that part of the deviation over case-II waters arose from a lack of near-infrared vicarious calibration. We expect the GOCI-II atmospheric correction algorithm to be improved and updated regularly to the GOCI-II data processing system through continuous calibration and validation activities.