• Title/Summary/Keyword: 측정학

Search Result 18,889, Processing Time 0.038 seconds

A PC-based instrumental system for fast measurement and analysis of power losses in DC-DC converter (DC-DC 컨버터의 고속 손실측정과 분석을 위한 PC 기반 계측시스템)

  • 안태영;주정규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.569-575
    • /
    • 2003
  • This paper present a new fully-automated PC-based instrumental system that could quickly measure and analyze the efficiency of switching power supplies for the entire operating range. In the proposed system, we applied an Indirect method for high-voltage low-current measurements and a direct method for low-voltage high-current measurements, in order to obtain a high accuracy with minimum equipment requirement. Compared to the conventional methods, the newly proposed system offers more accurate and much faster real-time assessment of the efficiency with minimum measurement error. The performance and accuracy of the proposed system are verified using a 50 W switching power supply intended for telecommunication applications.

A Study on Satellite Alignment Measurements Accuracy Improvement (인공위성 정렬 측정 정확도 향상을 위한 연구)

  • Choi, Jung Su;Kim, In-Gul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.12
    • /
    • pp.987-995
    • /
    • 2020
  • Accurate alignment between high-performance payloads and attitude control sensors is essential factor to guarantee accurate attitude orientation and high pointing stability of the satellite. Space craft developers often use theodolite measurement system for satellite alignment during ground AIT(Assembly Integration and Test) phase. When measuring theodolite, errors may occur due to line of sight error, tilting axis error, vertical index error, and vertical axis error. In addition, errors that can occur during alignment measurements with multiple theodolites are analyzed through the alignment cube measurements test. Based on the alignment cube measurements test, a technical method that can improve the alignment measurement accuracy was suggested and it's measurements results satisfied the satellite design requirements.

Tacho Pulse Non-uniformity Effects on Pulse Count Method (타코펄스 불균일성으로 인한 펄스개수측정방법 영향성)

  • Son, Jun-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.4
    • /
    • pp.301-309
    • /
    • 2021
  • Pulse count method is the classical reaction wheel speed detection method. In this study, we represent the pulse count method as mathematical equations. Instead of rotation speed, we model the reaction wheel rotation through rotation angle during sampling periods. We verified the effectiveness of the proposed model by comparing the pulse counts variation and averaging method effects from the model and previous research results. Then, we add tacho pulse non-uniformity to this verified model, and examine the errors of pulse count method. We express the measurement error increasement due to non-uniformity as mathematical equations, and also shows the requirement of moving average numbers to offset the measurement errors.

A Study on Smart Soil Resistance Measuring Device for Safety Characterized Ground Design in Converged Information Technology (ICT 융합 환경에서의 안전 특성화 접지 설계를 위한 스마트 대지 저항 측정 기술에 관한 연구)

  • Kim, Hong-Yong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.203-209
    • /
    • 2019
  • In this work, a new land-specific resistance measuring device (GM) and a measuring probe (Grounding Rod) are connected to the WENNER quadrant as power-line communication (PLC). In groups of two (P1,P2) probes, five to ten probes are installed in series on the ground at intervals of 1m, 2m, 4m, 8m, and 16m, respectively. If the PLC signal from the GMD is detected by the receiver of the Probe 1 (P1) for measurement, the minute voltage and current for measurement flow from the PSD (power supply) attached to the probe to the ground, and then, through the soil between P1 and P2, enters the Probe 1 (P2). The resistance value is then measured by the principle of voltage drop due to ground resistance. Measure the earth resistance every T seconds up to 1 trillion and store the measured data on the Arduino Server mounted on the main equipment. Stored measurement data can be derived from formulas by Ohm's Law and from inherent resistance (here,). Data obtained in real time will be linked to CDGES programs installed on Main PC, enabling data analysis and real-time monitoring of the ground environment on land. In addition, a three-dimensional display is possible with 3D graph support by identifying seasonal characteristics such as temperature and humidity of land (soils). The limitations of the study will require specific application measures of Test Bed for commercial access to a model that has been developed and operated experimentally.

Susceptibility of Mutans streptococci in the Planktonic and Biofilm State to Erythrosine (부유 상태와 바이오필름 상태에서 Mutans streptococci의 Erythrosine에 대한 감수성 평가)

  • Gong, Jungeun;Seo, Hyunwoo;Lee, Siyoung;Park, Howon;Lee, Juhyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.135-138
    • /
    • 2019
  • The aim of this study was to investigate the susceptibility of Mutans streptococci in both planktonic and biofilm states to erythrosine. S. mutans was cultured in brain-heart infusion (BHI) broth. Erythrosine was diluted in BHI broth and prepared at a concentration range of $0.02-10000{\mu}g/L$. The minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) were measured using the microdilution method. After forming biofilms on 96-well plates, the minimum biofilm inhibitory concentration (MBIC) and minimum biofilm eradication concentration (MBEC) were measured. S. mutans was susceptible to erythrosine in both planktonic and biofilm states. MIC and MBC values were both $19.5{\mu}g/L$ for the planktonic state, while MBIC and MBEC values were $313{\mu}g/L$ and $2500{\mu}g/L$, respectively, for the biofilm state. Erythrosine ($19.5{\mu}g/L$) exhibited a bactericidal effect on S. mutans (killing 99.9%) in the planktonic state. For biofilms, erythrosine inhibited biofilm growth and eradicated 99.9% of biofilm bacteria at higher concentrations than MIC and MBC. These MBIC and MBEC concentrations are much lower than known noxious doses, and the MIC, MBC, and MBIC values were even lower than clinical concentrations.

A Study on the Instrument Measuring Microscopic Movements using a LASER Light Source (레이저 광원을 이용한 극미세 진동 특정장치에 관한 연구)

  • 강성철;지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.17-21
    • /
    • 1994
  • 레이저 광원을 사용하여 정현적으로 극미세 진동하는 압전소자에 부착된 거울을 대상으로 마이켈슨 간섭계로 부터의 간섭신호를 감지해 변위의 크기와 주파수를 측정할 수 있는 진동측정 방법과 장치를 제시한다. 약 80[nm]~1.2[$\mu\textrm{m}$] 범위의 진폭을 가진 물체의 변위와 주파수를 매우 높은 정밀도로 측정하고, 빔의 파장보다 큰 진동물의 간섭신호를 컴퓨터로 처리하여 진동형태의 개형을 구해다.

  • PDF

Design of Electrostatic Bonding Equipment for Large Area and the Effect of Contamination Particle on the Si-glass Electrostatic Bonding (대면적 정전 접합 장치 고안 및 Si과 Glass 접합에 미치는 불순물의 영향)

  • Mun, Je-Do
    • Korean Journal of Materials Research
    • /
    • v.6 no.1
    • /
    • pp.3-11
    • /
    • 1996
  • 대면적 정전 접합 장치를 고안 및 제작하여 Si과 glass를 정전 접합시켰다. 여러 온도에서 정전 접합 후 접합 면적을 측정하였으며 접합이 이루어진 경우 그 접합 면적이 90%를 넘었다. 접합시 전류를 측정하여 접합 강도와의 관계를 살펴보였다. 잔류 공공을 생성시키는 원인은 재료의 표면 거칠기 차이나 전극의 모양보다는 불순물 입자에 의한 것임이 밝혀졌고 같은 크기의 불순물 입자에 대한 공공의 크기는 접합 온도가 높을수록 감소하였다. 정전 접합에 미치는 불순물의 영향을 공공의 크기 및 불순물 입자의 크기를 측정하여 살펴보았다.

  • PDF

A research on the pressure error correction (기압오차 보정에 관한 연구)

  • Lee, Ju-Ha;Yoo, Tae-Euk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.3 no.1
    • /
    • pp.145-159
    • /
    • 1995
  • 정확한 고도, 속도의 측정은 항공기의 효율적인 운영과 안전에 필수적이다. 정확한 고도의 측정은 지형 장애물의 회피와 항로상에서 최저 수직 고도 분리를 유지하기 위해 절대적으로 필요하다. 또한 정확한 속도의 측정은 저속(실속상태)에서 조종상실을 피하고 고속에서 항공기의 구조적 한계와 공기 역학적 한계의 초과를 방지한다. 따라서 비행시험을 통하여 고도와 속도를 정확히 보정해줌으로써 비행안전과 재산상의 손실을 막을 수 있다.

  • PDF

A Method for Noninvasive Diagnosis of Bone using Ultrasonic Doppler Method (초음파 Doppler법에 의한 생체 경조직의 비침투적인 진단을 위한 기초실험)

  • 박무훈
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.7
    • /
    • pp.3-11
    • /
    • 1998
  • 본 논문에서는 분포정수선로의 간단한 모델을 이용해서, 외부에서 진동을 가했을 때 에 뼈 표면에서 발생하는 굴곡파의 전파속도와 종파의 전파속도를 구할 수 있는 새로운 측 정원리를 제안했다. 이 측정원리를 이용해서, 봉(brass, polymethylmethacrylate)표면에 발생 하는 정재파에 대한 속도의 공간분포를 laser Doppler법으로 측정해서, 각각의 주파수에 대 한 전파속도를 구했다. 이 새로운 측정방법은 in vivo에서 초음파 Doppler법을 이용해서 뼈 의 이상(골다공증, osteoporosis)진단의 가능성을 제시했다.

  • PDF

화재 사례를 통한 양초 연소시간 측정 실험

  • Mun, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.7 no.1
    • /
    • pp.49-54
    • /
    • 2005
  • 본 실험은 방화 사건 현장에서 지연 착화 재료로 쓰이는 양초의 연소 시간을 측정키 위해 실험을 수행하였고, 시중에서 판매되는 양초는 종류, 크기, 제조사별 모두 다른 연소 시간을 나타나는 결과를 확인하여 양초에 대한 일괄적인 연소량, 시간에 비례되는 공통적인 자료를 도출할 수 없다는 결론을 얻었다. 사건 현장에서 지연 착화의 재료로 사용한 양초가 발견된다면 그 양초를 시료로 한 현장의 분위기를 조건으로 연소실험을 통하여 연소량에 비례하는 시간 측정결과로 착화 시간을 추정해야 하다는 결론을 얻었다.

  • PDF